Mate-’n’-Lok®is a registered trademark of AMP Company.
DeviceNet™ is a trademark of the Open DeviceNet Vendors
Association.
The dual series is the first package that offers multiple control
zones in one package. Watlow’s SERIES 935, 93, SD or 96
can be used as the control for the dual series. Each zone
utilizes a solid state relay for longer heater life and a lower
cost than other power switching devices. The heater output
connector can be ordered as either an Amp Mate-’n’-Lok
®
or
a twist and lock connector.
Specifications
Controller
• Watlow SERIES 935 • Watlow SERIES 93
• Watlow SERIES SD • Watlow SERIES 96
Dimensions
• 114 mm H x 152 mm W x 191 mm D
(4.5 in. H x 6.0 in W x 7.5 in. D)
Output Power Switching
• Utilizes solid state relays
• Output is powered through line cord
• Light duty dual
• 8 amp maximum load (4 amps per zone)
• Heavy duty dual
• 16 amp maximum load (8 amps per zone)
• Light duty control/limit
• (8 amps maximum load)
• Heavy duty control/limit
• (12 amps maximum load)
Power Requirements
• Light duty dual or controller/limit
• 120VÅ(ac), +10 percent, -15 percent (NEMA 5-15 plug)
• 208/240VÅ(ac), ±10 percent, -15 percent
(NEMA 6-15 plug)
Features
• Small foot print
• Pre-wired outputs
• Amp Mate-’n’-Lok
®
2-pin or a twist and lock output
connection
• Miniature thermocouple connector
• Watlow SERIES 935, 93, SD or 96 controllers
• ON/OFF rocker switch
Dual Control Console
Ordering Information
Dual Control Console
D U A L - - 0 0
Control
A = SERIES 96 w/ramp and soak
B = SERIES 96/97 w/ramp and
soak, EIA-232 comms
E = SERIES 96 w/EIA-485 comms
F = SERIES SD (
1
/16DIN)
w/EIA-485 comms
G = SERIES SD (
1
/32DIN)
w/EIA-485 comms
H = SERIES SD (
1
/16DIN)
w/DevicNet™ on CAN
J = SERIES SD6C/SD6L
Controller/Limit (
1
/16DIN)
w/DevicNet™ on CAN
1 = SERIES 935
3 = SERIES 93
4 = SERIES 96
5 = SERIES SD (
1
/32DIN)
7 = SERIES SD (
1
/16DIN)
8 = SERIES 96/97
Controller/Limit
9 = SERIES SD6C/SD6L
Controller/Limit
0 = SERIES SD3C/SD3L
Controller/Limit
Input
J = Type J thermocouple
K = Type K thermocouple
T = Type T thermocouple
R = RTD (2-wire)
Display
935
RX = Red
GX = Green
93/96/SD
RG = Red/Green (only color option
available on SD (
1
/32DIN))
RR = Red/Red
GG = Green/Green (only available on
SERIES 93 and 96)
GR = Green/Red (only available on
SERIES 93 and 96)
Output Connector
1 = AMP Mate-’n’-Lok
®
2 = Twist and lock
Line Voltage
1 = 120VÅ(ac) (light duty - 4A per zone; 8A total)
2 = 208/240VÅ(ac) (light duty - 4A per zone; 8A total)
3 = 120VÅ(ac) (heavy duty - 8A per zone; 16A total)
Control/Limit: Light Duty - 8A total; Heavy Duty - 12A total
• Heavy duty dual or controller/limit
• 120VÅ(ac), +10 percent, -15 percent (NEMA 5-20 plug)
Operating Environment
• 0 to 45˚C (32 to 113˚F)
• 0 to 90 percent RH, non-condensing
Weight
• 2.3 kg (5 lbs)