Warner Electric MCS-836-2, MCS-836-1, MCS-144, MCS-152, MCS-149 Service & Installation Instructions

...
Warner Photoscanner MCS-836/836-1/836-2
®
MEX (55) 53 63 23 31 QRO (442) 1 95 72 60
MTY (81) 83 54 10 18 ventas@industrialmagza.com
Multi-Function Plug-In Timer Modules
MCS-144, 149, 152, 159 Photoelectric Controls
P-241-78
Service & Installation Instructions
An Altra Industrial Motion Company
2.520 MAX.
P1
P2
1.650 MAX.
.450 .300
POST INSERTION
.200 .015
+
-
1 2 3 4 5 6
B
A
+-
SWI
.156
1.600
1.912
COMPONENT SIDE
Decrease
Outline Diagram
.5625 MAX.
.093 MAX
.062 .008
.062 .015
+
-
+
-
MOUNTING POST
®
MEX (55) 53 63 23 31 QRO (442) 1 95 72 60
MTY (81) 83 54 10 18 ventas@industrialmagza.com
Specifications
Mounting: Plug-in, mates directly with
connector on photoelectric amplifier board.
Timing Controls: Potentiometers, adjustable
Weight: 1 oz.
Ambient Temperature: 0 - 125ºF. (-18 –– +52°C)
Light or Dark Operation: Selectable
Timing Ranges: MCS-836: 0.4 to 15 seconds
MCS-836-1: 1 to 30 seconds
MCS-836-2: 0.02 to 0.5 seconds
Minimum Input Pulse: 20 milliseconds for delay
pull, delay drop, and dual delay. 50 microseconds for one-shot and delayed
Minimum Reset Time: 1 millisecond for all
Electrical: Pin No. Function
one-shot
functions
+ +24 VDC Input
Part Numbers: MCS-836: 7400-448-024
- Return (ground) A Timer Input B Timer Output
MCS-836-1: 7400-448-029 MCS-836-2: 7400-448-030
Warner Electric • 800-825-9050 P-241-78
2
Operations
The timer module is an optional plug-in device which modifies the basic on-off photoelectric control operation. These functions are necessary for special timing applications. Dark-to-Light and Light-to-Dark transitions may be used to trigger any function, as selected.
Delay Pull: This function provides a delayed response for pull-in (energize) of the output device. The time delay is adjustable from 0.4 to 15 seconds.
Loading...