Waldorf RN8200G Series, RN8400G Series, RN8600G Series, RN8800G Series, RNL8200G Series Installation And Operation Manual

...
Installation and Operation Manual
Gas Cooktops
Series RN8200G RN8400G RN8600G RN8800G
Date Purchased
Serial Number
Service Provider
228605-25
For use in GB, IE & DK
RNL8200G RNL8400G RNL8600G RNL8800G
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previously in writing by the manufacturer.
In line with policy to continually develop and improve its prod ucts, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. May 2014.
MANUFACTURED BY
Moffat Limited
Christchurch New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Contents
Waldorf Gas Cooktops
RN(L)8200G Gas Cooktop 300mm wide. RN(L)8400G Gas Cooktop 600mm wide. RN(L)8600G Gas Cooktop 900mm wide. RN(L)8800G Gas Cooktop 1200mm wide.
Introduction .............................................................................................. 2
Specification .............................................................................................. 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection
Dimensions ................................................................................................ 6
Installation .............................................................................................. 11
Installation Requirements Unpacking Location Clearances Assembly Fitting Adjustable Feet / Rear Rollers to Leg Stand Units Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases Gas Connection Commissioning
Operation ................................................................................................. 17
Operation Guide Description of Controls Open Burners ('F' - Flame Failure Option) Open Burners ('PF' - Pilot and Flame Failure Option) Griddle
Cleaning and Maintenance ...................................................................... 20
Before Commencing Cleaning Open Burner Cleaning Griddle Plate Cleaning Stainless Steel Surfaces
Fault Finding ............................................................................................ 22
Gas Conversion and Specifications ......................................................... 23
Conversion Procedure Gas Specifications
Replacement Parts .................................................................................. 28
2
Introduction
We are confident that you will be delighted with your WALDORF GAS COOKTOP, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Waldorf Gas Cooktops, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for adapting the appliance to the conditions for use in that country.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T
HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
 I
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning
3
Specifications
Model Numbers Covered in this Specification
RN[1]8200G-[2]-[3] 2 Open Burners. RN[1]8203G -[3] 300mm Griddle.
RN[1]8400G-[2]-[3] 4 Open Burners. RN[1]8403G-[2]-[3] 2 Open Burners + 300mm Griddle. RN[1]8406G -[3] 600mm Griddle.
RN[1]8600G-[2]-[3] 6 Open Burners. RN[1]8603G-[2]-[3] 4 Open Burners + 300mm Griddle. RN[1]8606G-[2]-[3] 2 Open Burners + 600mm Griddle. RN[1]8609G -[3] 900mm Griddle.
RN[1]8800G-[2]-[3] 8 Open Burners. RN[1]8803G-[2]-[3] 6 Open Burners + 300mm Griddle. RN[1]8806G-[2]-[3] 4 Open Burners + 600mm Griddle. RN[1]8809G-[2]-[3] 2 Open Burners + 900mm Griddle.
NOTE:
[1]: - Back Options;
- - Standard Models. L - Low Back Model s.
[2] - Open Burner Options;
F - With Flame Failure Protection. PF - With Pilot and Flame Failure Protection.
[3] - Base Stand Options;
B - Bench Mount. CB - Cabinet Base (excluding RN8200G Series). LS - Leg Stand (excluding RN8200G Series). RB - Refrigerated Base (RN8600G and RN8800G Series only).
General
A heavy duty, high efficiency Cooktop for modular kitchens. It has a high option Cooktop / Griddle arrangement and is available either on industrial adjustable feet or on robust rollers. Griddle options with 4 models of base unit available (except RN8200G model). Fitted with either 'Individual Flame Failure' (F) or 'Pilot and Flame Failure' (PF) option for each open burner. Griddles are fitted with pilot, flame failure and piezo ignition as standard. Easy clean stainless steel external finish.
4
Specifications
Gas Supply Requirements
- Australia
- New Zealand
- United Kingdom
Category: II
2H3P
(20, 37).
Flue Type: A1.
* - Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See ‘Gas Connection’ information overleaf.
Natural Gas LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section 21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Connection
See ‘Gas Connection’ information overleaf.
Natural Gas (G20) Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Open Burner
(each)
Griddle
(each 300mm section)
Heat Input (nett)
Nominal
6.5 kW 5.5 kW 6.5 kW 5.5 kW
Reduced
1.75 kW 1.85 kW 1.75 kW 1.95 kW
Gas Rate (nett)
Nominal
0.69 m3/hr 0.58 m3/hr 0.51 kg/hr 0.43 kg/hr
Reduced
0.19 m3/hr 0.20 m3/hr 0.14 kg/hr 0.15 kg/hr
Supply Pressure 20 mbar 30 / 37 mbar Burner Operating Pressure (*) 9.5 mbar Gas Connection See ‘Gas Connection’ information overleaf.
26 mbar
5
Specifications
- All Other Markets
NOTE:
 (*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear and 655mm from floor (55mm for bench top – B models) and is reached from beneath appliance. (Refer to ‘Dimensions’ section). With exception of RN8200G-B and RN8203G-B models which are 100mm from right hand side, 32mm from rear and 70mm from floor.
Connection is ½" BSP male thread (for RN8200G and RN8203G models). Connection is ¾" BSP male thread (for all other models).
Natural Gas Town Gas (**)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr 21 MJ/hr
Supply Pressure
1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa 0.63 kPa
Gas Connection
See ‘Gas Connection’ information below.
LP Gas / Butane
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Connection
See ‘Gas Connection’ information below.
6
Dimensions
Bench Models
Refer to Page 9 for Cooktop options
= Rating Plate Location for
this option.
R
RN
(L)
8400G-B
RN
(L)
8200G-B
R
RN
(L)
8600G-B
RN
(L)
8800G-B
7
Dimensions
Cabinet Base Models
RN8200G Models - not available in Cabinet Base option.
RN
(L)
8400G-CB
RN
(L)
8600G-CB
R
= Rating Plate Location for
this option.
R
RN
(L)
8800G-CB
Refer to Page 9 for Cooktop options
8
Dimensions
Leg Stand Models
RN8200G Models - not available in Leg Stand Base option.
RN
(L)
8400G-LS
Refer to Page 9 for Cooktop options
= Rating Plate Location for
this option.
R
R
RN
(L)
8600G-LS
RN
(L)
8800G-LS
Loading...