Waldorf RN8100G, RNL8100G, RNB8100G, RNLB8100G Installation And Operation Manual

Installation and Operation Manual
Gas Target Top
Date Purchased
Serial Number
Dealer
228092-20
For use in GB & IE
RN8100G RNB8100G RNL8100G RNLB8100G
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized previous ly in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. November 2014.
MANUFACTURED BY
Moffat Limited
Rolleston 7675 New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3833
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
Contents
Waldorf Gas Target Top
RN(L)(B)8100G Target Top - 900mm.
Introduction ............................................................................................. 2
Specifications ........................................................................................... 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection
Dimensions ................................................................................................ 5
Weight
Installation ................................................................................................ 9
Installation Requirements Unpacking Location Clearances Assembly Fitting Adjustable Feet / Rear Rollers to Leg Stand Units Fitting Adjustable Feet / Rear Rollers to Cabinet and Refrigeration Bases Gas Connection Commissioning
Operation ................................................................................................. 15
Operation Guide Description of Controls Lighting Pilot Burner Lighting Main Burner
Cleaning and Maintenance ...................................................................... 17
General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance
Fault Finding ............................................................................................ 19
Gas Conversion and Specifications ......................................................... 20
Conversion Procedure Gas Specifications
Replacement Parts List ........................................................................... 23
Introduction
2
We are confident that you will be delighted with your WALDORF TARGET TOP, and it will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Waldorf Target Top, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your WALDORF dealer promptly. In many cases a phone call could answer your question.
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T
HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
 I
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
 DO NOT
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.

DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
Warning

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CA N CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
Warning
INSTRUCTIONS
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
Warning
Specifications
3
Model Numbers Covered in this Specification RN[1]8100G - [2] Gas Target Top, 900mm wide.
NOTE:
[1]: - Model Options;
- - Standard. L - Low Back. B - Bold Front. LB - Low Back and Bold Front.
[2] - Base Stand Options;
B - Bench Mount. CB - Cabinet Base (excluding RN8200G Series). LS - Leg Stand (excluding RN8200G Series). RB - Refrigerated Base (RN8600G and RN8800G Series only).
General
A commercial heavy duty, gas fired Target Top having a high output, two stage double-ring cast iron burner offering accurate temperature control and infinitely variable heat with heat radiating out from centre of Target Top. Main Burner is located underneath removable cast target top plates. Target Top is constructed as a hob unit and is available on Leg Stand (-LS), Bench Mount (-B), Cabinet Base (-CB) or to fit on a Refrigeration Base Unit (-RB).
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category: II
2H3P.
Flue Type: A
1.
(*) Measure Burner operating pressure at target top hob manifold test point with target top burner (Inner and Out er rings)
operating at full setting. Operating pressure is ex-factory set, through applian ce regulator and is not to be adjusted, apart from when carrying out gas conversion, if required. (Refer to details in ’Gas Conversion’ section for information).
Natural Gas LP Gas (Propane)
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 1.0 kPa (*) 2.6 kPa (*) Gas Connection ¾” BSP Male
Natural Gas LP Gas
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 1.0 kPa (*) 2.6 kPa (*) Gas Connection ¾” BSP Male
Natural Gas (G20) Propane (G31)
Heat Input (nett)
Nominal 11.5 kW 11.5 kW Reduced 4.7 kW 7.9 kW
Gas Rate (nett)
Nominal 1.22 m3/hr 0.89 kg/hr Reduced 0.50 m3/hr 0.61 kg/hr
Supply Pressure 20 mbar 37 mbar Burner Operating Pressure (*) 9.9 mbar 26.8 mbar Gas Connection
3
/4” B.S.P. Male
Pilot 200 W 200 W
Pilot 0.02 m3/hr 0.02 kg/hr
Specifications
4
- All Other Markets:

(*) Measure burner operating pressure at target top hob mani fold test point with target top burner (Inner and outer ring) operating at full setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factor y set and is not to be adjusted, apart from when
converting between gasses, if required.
 (**) TOWN GAS Only - Burner operating pressure is to be adjusted using ad justable gas regulator supplied.
Town Gas Option is only available with specific ex-factory built Town Gas models, which can also be converted to any other gas. Standard models can only be converted betw een Nat. Gas, LP Gas and Butane, but not Town Gas.
 Refer to ‘Gas Conversion and Specifications' section of this manual for further details.
Gas Connection
Bench Models Only.
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear, 55mm from floor and is entered from beneath appliance. An optional underside connection is available.
Cabinet and Refrigeration Base Only.
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear, 655mm from floor and is entered from beneath appliance. An optional underside connection is available.
Connection is ¾” BSP male.
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation Manual supplied with appliance.
Natural Gas Town Gas (**)
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa Burner Operating Pressure (*) 1.0 kPa 0.63 kPa Gas Connection ¾” BSP Male
LP Gas (Propane) Butane
Input Rating (N.H.G.C.) 45 MJ/hr 45 MJ/hr Supply Pressure 2.75 - 4.50 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 2.6 kPa 2.6 kPa
Gas Connection ¾” BSP Male
Dimensions
5
RN
(L)
8100G-B
Weight (Nett)
RN8100G - B 160 kg.
Rating Plate
Location
Dimensions
6
RN
(L)
8100G-LS
Weight (Nett)
RN8100G - LS 180 kg.
Rating Plate
Location
Dimensions
7
RN
(L)
8100G-CB
Weight (Nett)
RN8100G - CB 200 kg.
Rating Plate