INSTALLATION INSTRUCTION
InvisiLED® Electronic Remote Transformer
EN-OD24100-RB2-T
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
• Read all instructions before installing.
• System is intended for installation by a qualied electrician in accordance with the National Electrical Code and
local regulations.
• Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch “OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
• Place the wall switch in the “OFF” position.
AVERTISSEMENT:
IMPORTANT : COUPEZ L’ÉLECTRICITÉ AVANT TOUTE MANIPULATION.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MAX LOAD 96W
MIN LOAD 1W
INPUT VOLTAGE 120VAC 0.84A 50/60Hz
OUTPUT VOLTAGE 24.0VAC 4AMAX
AMBIENT TEMP -20ºC TO 50ºC (-4°F TO 122°F)
INSTALLATION LOCATION Damp location listed (Not wet location)
PRODUCT DIMENSIONS:
HARDWARE:
A1 B1 D1
18”
d” Knockouts
62”
12”
4”
Mounting
Holes
E1
Wire Connector
Qty: 3pcs
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MARCH, 2016
Cover Screw
Qty: 2pcs
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Mounting Screw
Qty: 2pcs
24V Outdoor Tape Light
Female Connector
Qty: 1pc
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585

INSTALLATION INSTRUCTION
InvisiLED® Electronic Remote Transformer
EN-OD24100-RB2-T
Fig. 1
Cover Screw
B1
Female Waterproof
Connector
Cover
C1
E1
D1
Mounting Screw
Wire Connector
A1
Wire Conduit
(not included)
FEATURES:
• Electronic short circuit, overload, over temperature protection with auto-reset
• Class 2, UL listed
• Suitable for damp location – Locations protected from weather and not subject to saturation with water or other liquids but subject to
moderate degrees of moisture.
• InvisiLED outdoor tape is wet location listed, however install EN-OD24100-RB2-T in protected damp location. If wet location power supply is
required, refer to EN-O24100-RB2-T.
PREPARATION:
• Shut o the power at the circuit breaker.
• Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
• Transformer is to be installed away from heat sources and accessible for service.
INSTALLATION: (FIG.1)
1. Loosen two cover screws (B1) and remove the cover (C1).
2. Secure transformer box to suitable mounting surface using mounting screw (D1).
CONNECT THE WIRES: (FIG.2)
3. Remove appropriate power feed knockout in transformer box.
4. Bring building wires into knockout using cable connector.
5. Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
6. Secure the cover (C1) by tightening the two screws (B1).
7. To utilize Electronic Low Voltage (ELV) dimming, wire black (line hot) and white(line neutral) in accordance to dimmer specications.
8. Connect the output female connector of the power supply with the male connector of the InvisiLED outdoor tape. (as Fig.3).
Fig. 2
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Fig. 3
Power Supply
Tape Section
Securely tighten by hand
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MARCH, 2016