Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.
Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installations.
▸ If the hobs are used at an altitude of over 2,000 meters above sea level, a reduced performance must be expected.
The appliance is equipped with a connection cable which must be connected to an on-site junction box.
Error message U400
Faulty connection:
A pole conductor has been connected to the connection terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Ventilation
In order to guarantee good ventilation, a space of ≥10mm
height is necessary beneath the appliance.
1. The rear panel of the base unit must be open around the
work surface cut-out to guarantee continuous air circulation via the ventilation slits.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.
2. Alternatively, a concealed fresh air supply can ensure air
circulation inside the cabinet.
In order that enough cold air can be drawn in, there must
be a continuous circulation of fresh air that extends outside
the cabinet.
The air must be drawn in from outside the cabinet and be
able to circulate freely from inside the cabinet to the hob.
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for ventilation and service replacement over the entire cut-out area.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
RiCorner radii of applianceRaOuter corner radii of cut-out
Installation
1. Create an accurate installation cut-out.
– The mounting surface can be reamed out or created by installing wood/stone supports or using the steel angle set (see Accessor-
ies).
Access to the appliance from below via the entire cut-out area must be guaranteed. For servicing purposes, the induction generator can be removed from below with the mounting plate. It must be possible to unscrew the contact-proof covers from below.
2. Prepare the cut-out and appliance in accordance with the specifications in the enclosed cementing-in instructions.
3. Carefully cement the appliance in and leave the silicone sealant to dry for at least 24 hours.
4. Connect to the electrical mains connection before inserting the appliance, if necessary.
AWorktop depth (in combination with directly built-under oven; does not apply to small appliances)
BRequired clearance for ventilation and service replacement over the entire cut-out area.
HDimension from the top of the work surface to the underside of the hob (ventilation opening)
RiCorner radii of applianceRaOuter corner radii of cut-out
The appliances with oversize frames can also be used as a replacement for solid plate hobs and for installation in complete chromenickel steel covers. In the latter case, the solid plate hob part is cut out of the chrome-nickel steel cover and replaced by an appliance
(depth of the work surface ≥30mm). In contrast to normal installation without a fastening system, the appliance is fixed from below using adjusting braces.
7
Page 8
Installation instructions
1065985-R01
560–585
490–530
=
=
(30)
6 adjusting braces
Aim for
≤R10
≤25
≤32
ED
40
30
(≤ screw length)
(≤ screw length)
Warning, glass breakage:
Do not overtighten screws
Reinforcement of the cut-outs with
a complete chrome-nickel steel cover
The installation instructions with regard to electrical and safety-related issues remain fully valid for this installation.
1. Make a precise, right-angled cut-out in the work surface (if not already present). Aim to keep the cut-out dimensions to a minimum.
2. Securely clamp the appliance in the cut-out using the enclosed adjusting braces D and screws E. If necessary, install reinforcing
slats and use these to make the cover flat.
Arrangement of the adjusting braces
8
Page 9
Installation instructions
1065985-R01
393
(30)
≥67.5
5..10
53.5
56
ø4
≥15
(X)
H
≥3
≤
0.5
2.5
Caution: Mains cable must