VT-584 Outdoor Camera User Manual
Precautions: Do not install camera/bell where there would be a bright light behind the visitor
(or where there would be a bright background), or in a place where the camera lens would be
directly exposed to sunlight or a bright light. If light shines directly into the outdoor camera lens,
the image will be over-exposed; it will look white or silhouetted. Take precautions against this.
Do not install the unit in places where is constant vibration, extreme heat or unusual external
interference.
1. Product Features
● 4-wire Door Entry system, compatible with VT6xx series Monitors
● Camera angle adjustable
● Connects up to 5 Monitors
● Suitable for ush mounting
● Can also be surface mounted by rain cover (not included)
2. Parts List
● VT584 Door/bell camera 1 piece
● 4-Pin wire connector 1 piece (to connect Indoor Monitor)
● 3-Pin wire connector 1 piece (to connect lock)
3. Parts and Functions
1
2
3
4
5
4. Mounting Instruction
1. Cut a hole in 75mm X 75mm X
35mm in the wall. Insert the mounting
bracket and x with screws.
2. Wire up the cables, and test the
system.
3. Hang the door/bell camera body
on top of t he m ou nt in g box, t he n
ti ghte n t he scre ws f irm ly on t he
bottom.
VT-ENG-584-V2 090S817
1. Microphone
6
7
8
35mm
2. Camera
3. Night-View LED
4. Call Button
5. Speaker
6. Angle Adjust
7. Monitor Port
8. Unlock Port LB
145 cm
5. Connect an electron lock(power-ON-to-open)
Remove the JS/LK jumper on Monitor
Safety Type: Power-on-to-open
The lock consumption must not
greater than 12V 500mA.
The lock consumption must not
greater than DC 48V 1.5A.
Safety Type: Power-off-to-open
Keep the JS/LK jumper on Monitor
Safety Type: Power-on-to-open
Keep the JS/LK jumper on Monitor
The lock consumption must not
greater than 48V 1.5A.
1. When connecting an electric lock, an
external power supp ly is needed (not
included).
VT584
2. The rating of the lock must be less than
DC 48V 1.5A.
3. Connect the 2 Black wire to the power
(+), connect 1 Red wire to lock(+), and
connect the power (-) to the lock (-).
Adaptor
+ +
-
Electronic lock
6. Connect an electro-magnetic lock(power-OFF-to-open)
1. When connecting an electro-magnetic
lock, an external power supply is needed
(not included with this product).
VT584
2. The rating of the lock must be less than
DC 48V 1.5A.
Electron-Magnetic lock
3. Connect the 2 Black wire to the power
(+), connect 3 White wire to lock (+), and
connect the power (-) to the lock (-).
Adaptor
+
-
+
-
7. Connect a lock using the Monitor power only
1. When using the power solely from the
Monitor, only the Power-on-to-unlock type
electronic lock can be supported. The
rating of the lock must be less than 12V
500mA.
2. Connect the 2 Black wire to the 1 Red
wire from Monitor, connect 1 Red wire to
the lock (+), connect 2 White wire from
Monitor to the lock (-).
8. Specications:
● Power Supply: DC 10~12V (Powered by Monitors)
● Consumption: 150mA in working state (latch not included)
● Video Output: 75Ohm, 1Vp-p, CCIR standard (unless specied)
● Camera: 76 degree, CCD or CMOS camera with IR-LED
● Working temperature: -10 ~ 40 degree
VT584
Electronic lock
VT-ENG-584-V2 090S817