Vogt P118F User Manual

Vogt Tube - Ice machines P118
In 1938, Vogt Ice revolutionized the ice making industry by introducing
machines enjoy as well-earned reputation as the most energy
ecient , dependable ice machines on the market.
Heavy-duty industrial construction, automatic operation, and the best
warranty in the business make the Vogt ice machines the only “clear” choice for your ice making needs.
P118 Features
25 Year Life expectancy 5 Year compressor warranty* 25 Year evaporator warranty Highly Ecient Copeland Discus Compressor Manufactured in accordance with the A.S.M.E. code Environmentally friendly Refrigerant R404A
Controls U.L. Approved
Three settings are available:
Cylinder (Tube-Ice) only
7/8’’ Ice Diameter X 3/4’’ long 1 1/8’’ Ice Diameter X 1’’ long
1 3/8’’ Ice Diameter X 1’’ long
Crushed Ice only
3/16’’ to 1/4’’ thick on all models (approx.)
Dual Ice Option
Both Cylinder and crushed ice for split bins
:
*U.S. Domestic installations only.
www.vogtice.com
Voltage
Energy
Usage
Operating Conditions:
Lbs
Lbs
Air-Cooled Condensers:
In
Out
Return
Out
Shipping Weight
Line Size Connections
Air Cooled
Make-Up Temperature
Machine Weights
Water Cooled
Fan Motor(s)
Ice Making
Water Usage
Motor Information
Ice Machine Electrical Information
Machine Capacity
H.P.
Refrigerant Line Sizes from
Ice Machine to Condenser
13"
13 3/8"
10"
85"
1 -1/4" FPT
7 -1/2"
6 -5/8"
1 -1/4" FPT
-
28 3/8"
60"
11 3/4"
WATER IN
WATER OUT
1/2 MPT MAKE
UP WATER IN
P118
27 7/8"
49 -1/4"
106 - 1/8"
45 -1/2"
F.L.A. Ampacity Size (Amps) F.L.A. Ampacity Size (Amps)
208/230V, 3ph, 60hz 80.9 95.8 160 66.9 81.8 145
460V, 3ph, 60hz 39.7 46.9 80 32.7 39.9 70
200V, 3ph, 50hz 80.9 95.7 155 66.9 81.7 145
400V, 3ph, 50hz 40.2 47.4 80 33.2 40.4 70
Model Lbs
P118F - 1" 11,670 5293 11,000 4990 9,315 4225 2.92 1 3.79
P118F - 1 1/4" 11,200 5080 10,000 4536 8,400 3810 3.15 14.5 54.9 0.94 3.56 15 56.8
P118F - 1 1/2" 10,700 4853 9,500 4309 7,900 3583 3.23 0.93 3.52
NOTE: ENERGY USAGE AND WATER REQUIREMENTS BASED ON MAKEUP W ATER TEMPERATURE OF 70 O F AMBIENT (AIR) TEMPERATURE OF 90 O F AND 60HZ POWER.
CAPACITY RATING IS AV
MAKE-UP WATER USAGE INCLUDES 20 % BLOWDOW N. KWH VALUES BASED ON WATER COOLED UNITS.
The ice machine shall not be subjected to an atmospheric temperature lower than 50 oF nor
higher than 90 non-corrosive. The water shall be at a constant pressure of not less than 30 psig at the ice machine location. The condition of the water to make satisfactory responsibility of the purchaser.
o
F, without effect on performance. Water for ice making purposes shall be
Min. Max. Fuse Min. Max. Fuse Pump Motor
50oF (10oC) 70oF (21oC) 90oF (32 oC)
Kg
ERAGE FOR THE MODEL. INDIVIDUAL MACHINES MAY VARY +/- 5% . REDUCE 15% FOR 50HZ.
Lbs
Kg
ice shall be the
Lbs
127"
KWH/ Gal/ Liters/
Kg 100 lbs 100lbs 100lbs
Operating Weight
20 -1/2"
Water Cutter
1 1/2 1/2 (qty 2) @ 1 1/2
Ice Making Water
32"
Condenser
GPM
3300 1497 805 365
2975 1349 680 308
LPM
Kg
Compressor
Condenser
GPM
CondenserIce Machine
1/2" MPT
Drain Connections
The air-cooled condensers are available as remote units only, with 50/50 split coil and low ambient controls. Vogt requires that the air-cooled condensers be purchased from the Vogt factory for warranty consideration and in order to assure proper sizing and operation. The ice capacity with an air-cooled unit will be the same as a water-cooled unit as long a
ambient temperature does not exceed 90
o
above 90
F, the ice capacity will be decreased by approximately 3%.
o
F. For each 5 oF increase in ambient temperature
s the
Condenser Water Lines
CE FOR P112 & P118 AVAILABLE WITH 380V ONLY.
1 1/4" FPT
1 1/8" IDS
1 3/8" IDS
10
10
LPM
Kg
1" FPT
Revision 10/12/2012
Loading...