Vogt P118 Specifications

Vogt Tube - Ice machines P118
In 1938, Vogt Ice revolutionized the ice making industry by introducing
Heavy-duty industrial construction, automatic operation, and the best
warranty in the business make the Vogt ice machines the only “clear” choice for your ice making needs.
Three settings are available:
Cylinder (Tube-Ice) only
7/8’’ Ice Diameter X 3/4’’ long 1 1/8’’ Ice Diameter X 1’’ long
1 3/8’’ Ice Diameter X 1’’ long
Crushed Ice only
3/16’’ to 1/4’’ thick on all models (approx.)
Dual Ice Option
Both Cylinder and crushed ice for split bins
P118 Features
25 Year Life expectancy 5 Year compressor warranty* 25 Year evaporator warranty
Manufactured in accordance with the A.S.M.E. code Environmentally friendly Refrigerant R404A
Controls U.L. Approved
:
*U.S. Domestic installations only.
www.vogtice.com
VOGT TUBE-ICE MACHINES
®
Model
Ice Machine
Condenser
KNOCKOUTS FOR
CONNECTIONS
CENTER TO CENTER
ELECTRICAL
14 5/8"
10 1/2"
1/2" MPT MAKE-UP WATER IN
177 7/8"
BETWEEN MOUNTING HOLE CENTERS
147 5/8"
11/16" MOUNTING HOLES
10"
10 1/2"
CENTER TO CENTER
41 5/8"
BETWEEN MOUNTING
HOLE CENTERS
P118
28 3/4"
27"
Ice Machine Electrical Information
Air Cooled
Voltage
208/230V, 3ph, 60hz 76.9 91.8 155 66.9 81.8 145
460V, 3ph, 60hz 37.2 44.4 75 32.7 39.9 70
200V, 3ph, 50hz 83.9 100.4 170 73.1 89.6 160
400V, 3ph, 50hz 42.2 50.4 85 37.2 45.4 80
F.L.A. Ampacity Size (Amps) F.L.A. Ampacity Size (Amps)
Min. Max. Fuse Min. Max. Fuse Pump Motor
Machine Capacity
Make-Up Temperature
50oF (10oC) 70oF (21oC) 90oF (32 oC)
Model Lbs
P118F - 1" 9 7 . 3 12 9 . 23 7 1 40 0 2 , 9 0 9 9 40 0 0 , 1 15 2 6 5 0 0 4 , 2 1
P118F - 1 1/4" 11,200 5080 10,000 4536 8,400 3810 3.15 14.5 54.9 0.94 3.56 15 56.8
P118F - 1 1/2" 2 5 . 3 3 9 . 03 2 . 33 8 5 30 0 9 , 7 9 0 3 40 0 5 , 93 5 8 4 0 0 7 , 0 1
NOTE: ENERGY USAGE AND WATER REQUIREMENTS BASED ON MAKEUP WATER TEMPERATURE OF 70 O F AMBIENT (AIR) TEMPERATURE OF 90 O F AND 60HZ POWER.
CAPACITY RATING IS AVERAGE FOR THE MODEL. INDIVIDUAL MACHINES MAY VARY +/- 5% .
MAKE-UP WATER USAGE INCLUDES 20 % BLOWDOWN. KWH VALUES BASED ON WATER COOLED UNITS.
Kg
Lbs
Water Cooled
Kg
Lbs
Energy
Usage
KWH/ Gal/ Liters/
Kg 100 lbs 100lbs 100lbs
Motor Information
Water Cutter
1 1/2 1/2 (qty 5) 1/2
Condenser
Fan Motor(s)
H.P.
Water Usage
Ice Making
GPM
Compressor
Condenser
LPM
GPM
Machine Weights
CondenserIce Machine
Operating Conditions: Lbs
The ice machine shall not be subjected to an atmospheric temperature lower than 50 oF nor
higher than 90 non-corrosive. The water shall be at a constant pressure of not less than 30 psig at the ice machine location. The condition of the water to make satisfactory ice shall be the responsibility of the purchaser.
o
F, without effect on performance. Water for ice making purposes shall be
Shipping Weight
Operating Weight
Line Size Connections
Ice Making Water
3300 1497 700 318
2975 1349 667 303
Kg
Lbs
Drain Connections
Air-Cooled Condensers:
The air-cooled condensers are available as remote units only, with 50/50 split coil and low ambient controls. Vogt requires that the air-cooled condensers be purchased from the Vogt factory for warranty consideration and in order to assure proper sizing and operation. The ice capacity with an air-cooled unit will be the same as a water-cooled unit as long as the
ambient temperature does not exceed 90 oF. For each 5 oF increase in ambient
temperature above 90
o
F, the ice capacity will be decreased by approximately 3%.
Condenser Water Lines
Refrigerant Line Sizes from
Ice Machine to Condenser
In
Out
Return
Out
Vogt Ice, LLC
Revision 10/2009
1000 West Ormsby Ave., Louisville KY 40210 Phone: 502-635-3000
Engineered to Endure
E-mail: info@vogtice.com
10
15
LPM
Kg
1/2" MPT
1" FPT
1 1/4" FPT
1 1/8" IDS
1 3/8" IDS
Loading...