AW-IHT-0600 Industrial PoE Switch
AW-IHT-0601
Quick Installation Guide
INTRODUCTION
The AW-IHT-0600 series is a rugged media PoE switch designed for delivering a max. of 30 watts to powered devices.
The optional TX or FX uplink port can be used to extend the connection to a remote site. With its multi-purpose design, it
is t for IP surveillance, trafc monitoring, and security applications in critical environments. The machine features a total
budget of 126 watts and a wide range of operating temperatures ranging from -40°C to 75°C.
PACKAGE CONTENTS
* 1x PoE switch * 1x Quick Installation Guide * 1x 6-pin terminal block
* 2x wall mount brackets * 1x DIN rail bracket
IMPORTANT:
1. Install the switch in a ventilated and dry place that is free of electromagnetic source, vibration, moisture, and dust.
2. Make sure the ventilation openings on the switch are not blocked.
3. Use ber optic cables and transceiver compliant with the following: Multi-mode: 50/125um, 62.5/125um, 850nm;
Single-mode): 9/125um ,1310nm.
4. DC input: (AW-IHT-0600 - 44V~56VDC; AW-IHT-0601 - 12~56VDC). Follow the printed polarity for V+, V-, and Ground.
CONNECTION
1. Pull out the 6-pin terminal block.
2. Connect positive wires to V+, negative wires to V-, and
neutral wire to the ground screw.
Connect the 24V@1A pins to external devices. When 2
power pins are connected, the relay is shorted. When
any of them is diconnected, the relay connection is
open.
3. Connect SFP transceivers and ber cables to the ber
ports.
4. Install the 6-pin terminal block.
WARNING - Always ground the power source to maintain a clean power input.
F5 1000M
1 2
ON
T5 100M
LAN/WAN
IMPORTANT - You can either use the F5 ber or the T5 Ethernet port. These ports can not be
used at the same time. Use the DIP switch to make the selection.
Note that the conguration change only takes effect after a power cycle.
DIP 1 F5 Enable the F5 ber port (default)
T5 Enable the T5 Ethernet port
DIP 2 1000M ber port in the Gigabit mode
100M ber port in the 100Mbit mode
LED DEFINITIONS
PW1 ON When power is connected.
PW2 ON When power is connected.
ERR (relay) ON When both PW1 and PW2 are
connected.
OFF Only PW1 or PW2 is connected.
F5 ON Port 5 ber is detected.
OFF Port 5 ber is not detected.
Flashing Data is being transmitted or received.
F6 ON Port 6 ber is detected.
- OR -
Link ON TX link is detected.
SPD ON 1000M speed is detected.
P1,P2,P3,P4ON PD is detected on the designated port.
OFF Port 6 ber is not detected.
Flashing Data is being transmitted or received.
OFF Link is not detected.
Flashing Port is active.
OFF 10/100M speed is detected.
OFF No PD is detected.