Viking CVER53014BKA, CVER53014BRE, CVER53014BSS, CVER53014BSM, CVER53014BFW Installation Guide

...
0 (0)

Installation

GUIDE

5 Series

Freestanding 30” W Electric & 30” W Induction Ranges

VER5301 / CVER5301 VIR5301 / CVIR5301

Table of Contents

Warnings & Important Safety Instructions ____________________________________________________2 Dimensions______________________________________________________________________________4 Specifications ____________________________________________________________________________5 Clearance Dimensions (Proximity to Cabinets) ________________________________________________6 Clearance Dimensions (Wood/Composite Overlay)_____________________________________________7 Electrical Requirements ___________________________________________________________________8 General Information ______________________________________________________________________9 Installation _____________________________________________________________________________10

Door Removal____________________________________________________________________10 Leg Installation___________________________________________________________________10 Electrical Connection (3-wire) ______________________________________________________11 Electrical Connection (4-wire) ______________________________________________________12 Leveling/Adjustments/Alignment ___________________________________________________13 Anti-tip Device Installation _________________________________________________________14 Final Installation _________________________________________________________________16 Door Replacement and Adjustment _________________________________________________16

Performance Checklist ___________________________________________________________________17 Final Preparation ________________________________________________________________________18 Service & Registration____________________________________________________________________18

Important –Read and Follow!

Before beginning, please read these instructions completely and carefully.

Do not remove permanently affixed labels, warnings, or plates from product. This may void the warranty.

All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of codes, the National Fuel Gas Code ANSIZ223.1/NFPA-54 –latest edition.

The installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

In Canada: Installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes Part 1 and/or local codes.

2

Important –Read and Follow!

Your safety and the safety of others is very important.

We have provided many important safety

messages in this manual and on your appliance. Always read and obey all

safety messages.

This is the safety alert symbol.

This symbol alerts you to hazards that can kill or hurt you and others.

All safety messages will be preceded by the safety alert symbol and the word “DANGER,”“WARNING” or “CAUTION.” These words mean:

DANGER

Hazards or unsafe practices

which WILL result in severe personal injury or death

WARNING

Hazards or unsafe practices

which COULD result in severe personal injury or death

CAUTION

Hazards or unsafe practices which COULD result in minor personal injury or property damage.

All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

WARNING

To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194°F (90°C). Heat resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements.

DANGER

ELECTRICAL SHOCK HAZARD

To avoid risk of electrical shock, personal injury or death; verify your appliance has been properly grounded in accordance

with local codes or in absence of codes, with the National Electrical Code (NEC). ANSI/NFPA 70-latest edition.

WARNING

TIPPING HAZARD

To reduce the risk of the appliance tipping, it must be secured by a properly installed anti-tip bracket(s). To make sure the bracket has been installed properly, look behind the range with a flashlight to verify proper installation engaged in the rear top left corner of the range.

This range can tip.

A child or adult can tip the range and be killed.

Failure to install the device can result in death or serious burns

If the range is moved, the device must be re-engaged.

WARNING

MOVING HAZARD

To avoid risk of severe personal injury; this appliance requires two or more personnel while handling and moving.

Possible use of appliance moving devices is recommended.

3

Dimensions

29-

 

7/8”

(75.

 

9

cm)

 

1”

(2.

 

5

cm

 

 

)*

35-

 

(91.

 

7/8”

1

cm)

 

 

 

 

(940cm) min.

.

 

to

 

 

37”

max.

 

 

 

28-1/16” (71.2 cm)

26-7/16” (67.2 cm)

8-1/8”

(20.6 cm)

19-3/8”25-3/4” (65.4 cm) (49.2 cm)

45-1/8” (114.6 cm)

24-5/16” (61.8 cm)

*Note: Units shown with standard island trim.

1-5/8”

(4.1 cm)

1” (2.5 cm)

35-7/8”

(91.1 cm) min. to

37”

(94.0 cm) max.

4

Specifications

 

 

 

 

Description

 

VER/CVER5301

VIR/CVIR5301

 

 

 

 

Overall width

 

29-7/8” (75.9 cm)

Overall height

 

To top of glass frame

 

 

35-7/8” (91.1 cm) min.

 

 

37” (94.0 cm) max.

 

 

Legs adjust 1-1/8” (2.9 cm)

Overall depth from

 

To end of side panel—24-5/16” (61.8 cm)

rear

 

To front of door—25-3/4” (65.4 cm)

 

 

To end of landing ledge—28-1/16” (71.3 cm)

 

 

To end of door handle—28-11/16” (72.9 cm)

Additions to base

 

To top of island trim—add 1” (2.5 cm)

height

 

To top of backguard—add 8” (20.3 cm)

 

 

To top of high-shelf—add 23-1/2” (59.7 cm)

Electrical

 

See Electrical Requirements information.

requirements

 

 

 

 

 

 

Maximum amp usage

240V—62.8 amps

240V—60.0 amps

 

208V—54.6 amps

208V—52.0 amps

Surface element rating

Left Front

1,500 watts

(4) 9” Magna Quick Induction Elements

 

 

Left Rear

3,000 watts/1,400 watts

2300 W / 3700W

 

Right Front 1,800 watts

 

 

Bridge

800 watts

 

 

Right Rear

1,800 watts

 

 

 

 

 

Oven interior width

 

25-5/16” (64.6 cm)

Oven interior height

 

16-1/2” (41.9 cm)

Oven interior depth

 

AHAM 16-13/16” (42.7 cm) Overall—19-1/2” (49.5 cm)

Oven volume

 

Total oven capacity—4.7 cu. ft.

 

 

Measure to AHAM standards 4.1 cu. ft.

Approximate

 

426 lbs. (193.2 kg)

shipping weight

 

 

 

 

 

 

 

 

Minimum clearances from adjacent combustible construction

Cooking surface and below, i.e., 36” (91.4 cm) and below o Sides—0”

Above cooking surface, i.e. above 36" (91.4 cm) o Sides—6” (15.2 cm)

o Within 6” (15.2 cm) side clearance, wall cabinets no deeper than 13” (33.0 cm) must be minimum 18” (45.7 cm) above cooking surface.

o Wall cabinets directly above product must be minimum 36” (91.4 cm) for open top burners above cooking surface.

o Rear—0” with backguard or highshelf; 0” with island trim and noncombustible rear wall; 6” (15.2 cm) with island trim and combustible rear wall.

5

Viking CVER53014BKA, CVER53014BRE, CVER53014BSS, CVER53014BSM, CVER53014BFW Installation Guide

Clearance Dimensions (Proximity to Cabinets)

This range may be installed directly adjacent to existing 36” (91.4 cm) high base cabinets.

IMPORTANT: The side trim MUST be 3/8” (.95 cm) above the adjacent base cabinet countertop. This can be accomplished by raising the unit using the adjustment spindles on the legs.

The range CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36” (91.4 cm) high. There must be a minimum of 6” (15.2 cm) side clearance from the range to such combustible surfaces above the 36” (91.4 cm) counter height.

Within the 6” (15.2 cm) side clearance to combustible vertical surfaces above 36” (91.4 cm), the maximum wall cabinet depth must be 13” (33.0 cm) and wall cabinets within this 6” (15.2 cm) side clearance must be 18” (45.7 cm) above the 36” (91.4 cm) high countertop.

Wall cabinets above the range must be a minimum of 42” (106.7 cm) above the range cooking surface for the full width of the range. This minimum requirement does not apply if a range hood is installed over the cooking surface.

CAUTION

To prevent possible damage to cabinets and cabinet finishes, use only materials and finishes that will not discolor or delaminate and will withstand temperatures up to 194°F (90°C). Heat and moisture resistant adhesive must be used if the product is to be installed in laminated cabinetry. Check with your builder or cabinet supplier to make sure that the materials meet these requirements.

 

 

 

 

 

29-

 

 

 

 

 

 

 

 

 

7/8”

 

 

 

 

 

(75.

 

 

 

 

 

 

 

 

 

.

9

cm)

 

 

 

max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13”

0

cm)

 

 

 

 

 

(33

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min

6”

 

 

 

 

42”

.

7

cm)

 

 

 

 

 

 

 

 

 

(106

 

 

 

 

 

 

 

 

 

 

 

(15.min.

 

 

 

 

 

 

2

cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

Burn hazard.

To avoid risk of personal injury; the use of cabinets for storage above the appliance may result in a potential burn hazard.

Combustible items may ignite, metallic items may become hot and cause burns. If a cabinet storage is to be provided the risk can be reduced by installing a rangehood that projects horizontally a minimum 5” (12.7 cm) beyond the bottom of cabinets.

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

min

 

 

 

 

 

18”

 

cm

)

 

 

 

 

 

 

 

 

 

 

 

 

.7

 

 

 

36”

 

(45

 

 

 

 

91

.4

cm)

3/8”

 

 

 

(

 

 

 

 

 

 

 

 

cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0

.95

 

 

 

 

 

 

 

 

 

 

 

(7630” (opening.2 cm) width)

Note: Minimum clearance for back wall is 0” with backguard or high-shelf.

Note: If a range hood is installed, wall cabinets above the range have a different minimum clearance height.