The CPA-7B is a cost effective, multi- purpose, telecom
paging system.
The CPA-7B features a low noise, high fidelity amplifier,
providing 6 watts of power for a variety of telecom paging
applications. It can also provide background music and
night bell/common audible. In addition, multiple units
may be daisy-chained for larger paging applications.
Compatible with ringing C.O. lines, Centrex lines and
analog PABX/KSU station ports as well as unused trunk inputs, the CPA-7B will also
interface directly with standard paging ports. For loud ringing, the CPA-7B generates
an adjustable loud warble from a dry contact closure, a ringing C.O. or a ringing analog
PABX/KSU station.
The CPA-7B is easy to install and can eliminate the installation of multiple bells, relays
and paging cards.
• 6 watts of paging power (powers up to (8) 8
ohm horns/speakers)
• Increased audio fidelity with low noise
amplifier
• Interfaces with ringing C.O. lines, Centrex lines,
paging ports, unused phone system trunk
inputs, or ringing analog station ports
• 600 ohm audio output to connect multiple
CPA-7B’s for larger paging applications
• (1) 8 ohm 25AE paging horn included
• Day/night switchable for paging/loud ring
• Ringing/alert tone volume adjustment
• Paging volume adjustment
• Selectable ring trip paging and night bell
• Background music is muted during page
• 10 pin cage clamp terminal strip for easier
wiring
• Provides “Night Bell” warble tone via contact
closure or ringing analog circuit
• Provides page “Alert” tone before paging
• Adjustable ring trip paging time out for auto
disconnect
• Audio patch cord provided
• Paging and loud ringing for Centrex systems
• Paging and loud ringing for phone systems with
paging ports, unused analog station ports or
unused trunk inputs
Sales...(715) 386 - 8861
Made in the U.S.A.
Specifications
Power: 120V AC/13.8V AC 1.25 A, UL listed adapter provided
Amplifier: 6 watts - to power up to (8) 8 ohm speakers
(cascadable to drive additional speakers)
Dimensions: 133 mm x 89 mm x 44 mm (5.25” x 3.5” x 1.75”)
Shipping Weight: 1.36 kg (3 lbs)
Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-
Paging Horn (included), each additional horn will drop the output
level of all horns by 1dB
Maximum Speaker Cable Length: 91 m (300 ft) 18 AWG
Connections: (1) RJ11 jack, (1) 3.5mm (1/8”) audio jack, (1)
2.1mm barrel jack
Talk Battery Output: 19V DC (loop current 36mA nominal)
Page 2
Installation/Applications
A. Ring Trip Paging with or without Night Bell
1. Set the MODE SWITCH to the RING TRIP position.
2. Adjust the RING TRIP TIME OUT POT as required (adjustable from approximately 10 - 25 seconds).
3. Plug a C.O. line, Centrex line or analog PABX/KSU station into the PAGING INPUT PORT.
4. Make a sample page adjusting paging and alert tone volume.
5. With the night transfer switch off (open), the CPA-7B will answer and page, then disconnect on CPC or time out.
6. With the night transfer switch on (closed), the CPA-7B will broadcast a night bell ring (electronic warble tone)
during each incoming ring.
Caution: Do NOT connect speakers with a combined parallel impedance of less than 1 ohm. To power more
speakers, see Installation/Applications section F.
Up to (8) 8 ohm
speakers may
be connected
in parallel
B. Ring Trip Paging with Night Bell/Common Audible from Contact Closure
1. Set the MODE switch to the RING TRIP position.
2. Adjust the RING TRIP TIME OUT POT as required (adjustable from approximately 10 to 25 seconds).
3. Connect the phone system’s dry contacts to pins 5 and 7 and jumper terminal 6 to 10 as shown below.
Note: Common audible (night bell) takes precedence over ring trip paging.
Caution: Do NOT connect speakers with a combined parallel impedance of less than 1 ohm. To power more
speakers, see Installation/Applications section F.
Note: The “Common Audible” contact
closure (below) will activate during
incoming ring on the phone system’s
line inputs (programmable on many
systems). Night bell (electronic warble
tone) will then be broadcast in
cadence with the incoming ring.
Night Transfer Switch
(not included)
25AE
30AE
Phone System
Common Audible
N.O.
Dry Contact
Closure
(see Note above)
Up to (8) 8 ohm
speakers may
be connected
in parallel.
1. Set the MODE SWITCH to the TRUNK/PAGING PORT position.
2. Adjust the RING TRIP TIME OUT POT to its maximum (fully clockwise) position.
3. Connect terminal 8 to 5 to provide talk battery on the PAGING INPUT PORT.
4. Connect the unused trunk port to the PAGING INPUT PORT.
Note: If both paging and loud common audible are required, connect the night transfer switch (optional), the phonesystem common audible dry contacts and jumper terminal 6 to 7 as shown below.
Caution: Do NOT connect speakers with a combined parallel impedance of less than 1 ohm. To power morespeakers, see Installation/Applications section F.
Note: The “Common Audible” contact
closure (below) will activate during
incoming ring on the phone system’s
line inputs (programmable on many
systems). Night bell (electronic warble
tone) will then be broadcast in
cadence with the incoming ring.
Night Transfer Switch
(not included)
25AE
30AE
Phone System
Common Audible
Dry Contact
N.O.
Closure
(see Note above)
Up to (8) 8 ohm
speakers may
be connected
in parallel.
D. Paging from a Phone System’s 600 Ohm Paging Port (with page dry contact closure provided)
1. Set the MODE SWITCH to the TRUNK/PAGING PORT position.
2. Adjust the RING TRIP TIME OUT POT to its maximum (fully clockwise) position.
3. Connect the phone system’s paging port to the PAGING INPUT PORT.
4. Connect the phone system’s paging dry contacts to terminals 5 and 7. The contact closure will activate the alert
tone for paging and mute the background music.
Note: If both paging and loud common audible are required, wire the night transfer switch (optional) to the phone
system’s common audible dry contacts and jumper terminals 9 to 6 as shown below.
Caution: Do NOT connect speakers with a combined parallel impedance of less than 1 ohm. To power more
speakers, see Installation/Applications section F.
Note: The “Page” contact closure
(below) will initiate paging from the
phone system’s paging port. The
“Common Audible” contact closure
(below) will activate during incoming
ring on the phone system’s line inputs
(programmable on many systems).
Night bell (electronic warble tone) will
then be broadcast in cadence with the
incoming ring.
Page
N.O.
(see
Note
above)
Phone System
Dry Contact
Closures.
Common Audible
N.O.
(see
Note
above)
(not included)
Background
Music Source
6 ft audio
patch cord (included)
Up to (8) 8 ohm
speakers may
be connected
in parallel.
E. Paging from a Phone System’s 600 Ohm Paging Port
1. If the phone system does NOT provide a dry contact closure on “Page”, connect the paging port to the 3.5mm (1/8”) music inputjack.
2. If loud common audible is required, connect the night transfer switch (optional), the phone system’s common audible dry contacts and jumper terminals 6 to 7 as shown below.
Note: The CPA-7B can NOT provide background music or alert tones in this application.
Caution: Do NOT connect speakers with a combined parallel impedance of less than 1 ohm. To power morespeakers, see Installation/Applications section F.
closure (below) will activate during
incoming ring on the phone system’s
line inputs (programmable on many
systems). Night bell (electronic warble
tone) will then be broadcast in
cadence with the incoming ring.
Night Transfer Switch
(not included)
RING TRIP
TIME OUT
Adjustment
6 ft audio
POT
patch cord (included)
Note: For a RCA to stereo plug adapter,
order Radio Shack part #274-387.
25AE
30AE
25AE
30AE
Phone System
Common Audible
N.O.
Dry Contact
Closure
(see Note above)
Up to (8) 8 ohm
speakers may
be connected
in parallel.
F. Cascading Multiple CPA-7B’s to Drive Additional Speakers
An infinite number of CPA-7B’s may be daisy-chained together to a master CPA-7B to drive additional speakers as
required. Only the master CPA-7B should be connected to the paging source, background music, phone system’s
dry contact closures, etc. The master CPA-7B controls the paging and ring/alert tone volume for all units. Set
paging control volume on all slave units to the maximum position. Connect as shown below.
Up to (8) 8 ohm speakers
may be connected in parallel
Adjust
according
to your
application
Connect according
to your application
6 ft audio patch cord
(included)
Note: One end of the Audio Cord must be cut and
wired directly to pins 3 and 4 to use multiple CPA-7B’s.
Additional
Horns or
Speakers
Up to (8) 8 ohm speakers
may be connected in parallel
Note: One end of the Audio Cord must be cut and
wired directly to pins 3 and 4 to use multiple CPA-7B’s.
Not UsedNot Used
To
6 ft audio patch cord
(included)
Additional
Horns or
Speakers
Note: If a lower volume
setting is desired on one
slave unit, it must be
connected as the last unit
in the chain.
Additional
CPA-7B’s
Up to (8) 8 ohm speakers
may be connected in parallel
Product Support Line...(715) 386-8666 Fax Back Line...(715) 386-4345
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking
Electronics, its affiliates and/or subsidiaries assume no responsibility for errors and/or omissions contained in this information. Revisions of
this document or new editions of it may be issued to incorporate such changes.
Fax Back Doc # 455Printed in the U.S.A.
ZF301200 Rev A
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.