Viking CTG-1 User Manual

0 (0)

 

TECHNICAL

 

Clock Controlled

 

 

 

 

CTG-1

 

Practice

 

Tone Generator

TELECOM SOLUTIONS FOR THE 21ST CENTURY

 

February 27, 2007

 

 

 

 

 

 

 

Add Time Controlled Alert Tones and Emergency Tones to Your Paging System

Viking's model CTG-1 is a clock controlled tone generator designed to provide accurately timed bong alert tones or buzzer alert tone sounds over an existing paging system.

The CTG-1 can be programmed to output single, double or triple alert tones with up to 128 events in a 24 hour period. These bong/buzzer sounds are ideal for indicating the start and end of shifts, break times, lunch periods, etc. for factories, schools, or any busi-

ness requiring an audible indication of specified times. Each day of the week can be programmed to either on or off, allowing you to turn off the alert tones during specific days of the week (weekends, etc.)

The CTG-1 has three contact closure inputs for triggering an emergency siren, evacuation signal or a doorbell sound.

Features

Accurate 24 hour digital time clock displays hours and minutes

User programmable 24 hour, 128 event timer

Programmable day of week on/off feature

Programmable single, double or triple alert tone output (selectable bong or buzzer)

Three contact closure controlled sounds:

1)Emergency siren (yelp) sound

2)Temporal (slow whoop) evacuation signal

*NFPA/ANSI compliant when used with supporting equipment

3) Doorbell (chime) sound

Volume controllable, 600 ohm line level audio output

Non-volatile programming memory

Battery backup for maintaining clock time with factory installed 9V NiMh rechargeable battery

Two sets of DPDT relay contacts for muting paging or background music during alert tones

Applications

Signal the beginning and end of class periods, breaks, and lunch periods for schools

Signal the beginning and end of shifts, breaks, and lunch periods for factories and other businesses

Provides a doorbell and/or alarm sounds over an existing paging system, for such applications as door entry, fire, severe weather, etc.

Use with Viking's DVA-2WA to provide timed messages (Fax Back Document 110)

Phone...715.386.8861

http://www.vikingelectronics.com

Specifications

Power: 120V AC/13.8V AC 1.25A UL listed adapter provided Dimensions: 133mm x 91mm x 44mm (5.25” x 3.6” x 1.75”) Weight: 0.9 Kg (2 lbs)

Environmental: 0°C to 32°C (32°F to 90°F) with 5% to 95% non-condensing humidity

Connections: 12 position cage clamp terminal strip

Battery Backup: 9V NiMh rechargeable battery (factory installed) maintains clock time for over 8 hours

Time Base: 60Hz AC power line

Time Base Battery Backup Accuracy: +/- 50 ppm

Audio Output: 600 ohm with volume adjust potentiometer, maximum level = 17 dBm/5.4Vrms across 600 ohm load

Relay Output: DPDT rated 125V AC, 30 W (resistive load)

Viking CTG-1 User Manual

Features Overview

Mode Button: Press to place the CTG-1 in the

 

 

 

 

 

 

Display: Shows

 

 

DIP

Switches: See

Lock, Set Time, Set Day, Set Events or

 

 

 

 

 

 

clock, event time

 

 

Programming section

Review/Cancel modes.

 

 

 

 

 

 

and mode settings.

 

 

J.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clock and Event Time Setting Buttons: Press

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the + or -/CANCEL buttons to increase or

 

 

 

VIKING©

 

CLOCK CONTROLLED

 

 

 

 

 

 

 

 

decrease time. The -/CANCEL switch is also

 

 

 

 

TONE GENERATOR

 

 

 

 

 

 

 

 

 

 

 

MODEL CTG-1

 

 

 

 

 

 

 

 

ON

 

 

 

used to cancel an alert tone event when review-

 

 

 

PM

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing programming.

 

 

 

TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF

 

 

 

-/ CANCEL +

MODE

 

 

 

 

 

 

1 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alert Tones Programming Buttons: After set-

 

 

 

 

 

 

LOCK

 

 

 

 

 

 

 

 

 

 

SET TIME

 

 

 

ting an event time, press SINGLE, DOUBLE or

ALERT TONES

 

 

SET DAY

 

 

 

 

 

 

 

 

 

 

 

SINGLE

DOUBLE

 

TRIPLE

 

SET EVENTS

 

TRIPLE to program 1, 2 or 3 alert bongs/buzzer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REVIEW/CANCEL

 

sounds for that event time.

 

 

 

 

 

 

 

 

 

 

 

 

Secondary Button Functions While in the SET

 

VOL

1

2

3

4

5

6

7

8

9 10 11 12

 

DAY Mode: The SINGLE button is used to select

 

 

 

 

 

 

 

 

 

 

1

2

 

 

 

 

 

 

 

 

 

 

 

on

 

 

 

 

 

 

 

 

 

 

 

 

 

S1

between day (1-7) or on/off. The DOUBLE but-

9V BATTERY

 

 

 

 

 

 

 

 

 

 

BACKUP

 

 

 

 

 

 

 

 

 

 

 

ton is used as a one time setup to program

 

 

 

 

 

 

 

 

 

 

 

 

today’s day of the week.

 

 

 

 

 

 

 

 

 

 

 

 

12 - Common

9V Battery Backup Connection: A standard

 

 

 

 

 

 

 

11Emergency Siren (Yelp): Continuous while

 

 

 

 

 

rechargeable (NiMh) 9V battery is installed to

 

 

 

 

 

 

 

 

shorted to pin 12 (common).

 

 

 

 

 

 

 

 

 

 

 

 

 

maintain the clock time during power outages.

 

 

 

 

 

 

 

10 - Evacuation Sound (Temporal Slow Whoop):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Continuous while shorted to pin 12 (common).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

- Doorbell Chime Sound (Ding Dong): One

CTG-1 Output Volume Control: Turn clockwise

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

chime per closure.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to increase volume of alert bongs/buzzer sounds,

 

 

8

- N.O.

 

emergency and door bell (chime) sounds (see

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 - COM

Relay Contact

diagram below).

 

 

 

 

 

 

 

6 - N.C.

 

 

 

 

 

 

 

 

 

 

5

- N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

- COM

Relay Contact

* Note: When the buzzer alert tone is programmed, a double or

 

 

 

 

3

- N.C.

 

triple programmed event will be sounded twice, approximately

 

 

 

 

 

 

 

 

 

 

 

 

1

& 2 - 600 Ohm Audio Out Pair: Line level output,

 

 

 

 

 

three seconds apart.

 

 

 

 

 

 

 

 

connect to input of paging amplifier.

Installation

Connect the CTG-1 between your phone system and your paging amplifier as shown in the diagram below. The factory installed rechargeable 9V battery will maintain the clock time for over 8 hours.

IMPORTANT: The CTG-1 leaves the factory with the battery backup DIP switch turned OFF to avoid discharging the battery during shipment. The battery backup DIP switch MUST be set to ON (see Programming section J) to maintain clock time during a power outage.

PA-2A Paging/Loud Ringing

Amplifier System

VIKING©

MODEL PA-2A

 

 

PAGING

 

 

 

 

 

RINGING

 

 

 

VOLUME

VIKING

 

 

 

 

VOLUME

 

 

 

 

 

ELECTRONICS

 

 

 

 

 

 

 

 

 

 

HUDSON, WI 54016

 

 

 

 

 

 

 

AC

MIN

MAX

 

 

 

 

 

MIN

MAX

 

 

13.8V

 

PAGING - LOUD RINGING

 

 

 

 

 

 

 

AMPLIFIER SYSTEM

 

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

NIGHT TRANSFER

DRYCONTACT

CLOSUREIN

TRUNKOR

PAGINGPORT

600OHM

AUDIOOUT

PAGING

HORN

 

AUDIO LOADING

1

2

3

4

5

6

7

8

9

10

 

TALK BATTERY

 

 

 

 

 

 

 

 

 

 

 

 

ALERT TONE

 

 

 

 

 

 

 

 

 

 

 

WARBLE / CHIME

 

 

 

 

 

 

 

 

 

 

 

RINGING LINES

 

 

 

 

 

 

 

 

 

 

 

1 - 3

4 - 6

1 2 3 4 5 1

2

3

4

5

6

7

8

9

10

-or-

Input of

Paging Amp

VIKING©

 

TONE GENERATOR

 

 

 

 

CLOCK CONTROLLED

MODEL CTG-1

PM

 

TIME

 

 

 

- / CANCEL

+

MODE

 

 

 

 

 

LOCK

 

 

 

 

SET TIME

ALERT TONES

 

SET DAY

 

SET EVENTS

SINGLE

DOUBLE

TRIPLE

 

 

 

 

 

REVIEW/CANCEL

VOL 1

2

3

4

5

6

7

8

9 10 11 12

Dry Contact Closures from Alarm

9V BATTERY

 

 

 

 

 

 

 

 

Equipment, Doorbell Switch, Etc.

 

 

 

 

 

 

 

 

 

BACKUP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Common

 

 

 

 

 

 

 

 

 

Siren

 

 

 

 

 

 

 

 

 

Evacuation Signal

Paging port

 

 

 

 

 

 

 

 

output of

 

 

 

 

 

 

 

 

Doorbell

PABX/KSU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...
+ 2 hidden pages