Vermont Casting 1610 User Manual

Defiant
Non-Catalytic Woodburning Stove
Model 1610
Homeowner’s Installation and Operating Manual
For use in the United States and Canada
SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERLY INSTALLED, OPERATED AND MAINTAINED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT LOCAL BUILDING OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
Do Not Discard This Manual: Retain for Future Use
30002850 7/06 Rev. 2
Defiant 1610 Non-Catalytic Woodburning Stove
Welcome
Congratulations on your choice of a Vermont Castings Defiant stove. With this purchase you have made a commit­ment to make the hearth a place of warmth, beauty and comfort in your home. At CFM Corporation, we share that joy and appreciation for the hearth. We assure you that your cast-iron Vermont Castings stove has been made with the utmost care and will provide you with many years of service.
As you become acquainted with your new stove, you will find that its appearance is matched by its functionality, due to cast iron’s unique ability to absorb and radiate heat.
Also, CFM Corporation products are among the cleanest-burning wood stoves and fireplaces available today. As an owner of a Vermont Castings stove, you make a strong statement for pollution-free energy. However, clean burning depends on both the manufacturer and the operator. Please read this manual carefully to understand how to properly operate and maintain your stove.
At CFM Corporation, we are equally committed to your satisfaction as a customer. That is why we maintain an ex clusive network of the finest dealers in the industry. Our dealers are chosen for their expertise and dedication to customer service. They are factory-trained and knowledgeable about every CFM Corporation product. Feel free to contact your Authorized Vermont Castings Dealer anytime you have a particular question about your stove or its performance.
This manual contains valuable instructions on the installation and operation of your Vermont Castings Defiant. It also contains useful information on maintenance. Please read the manual thoroughly and keep it as a reference.
Sincerely,
-
All of Us at CFM Corporation
This manual describes the installation, operation, and maintenance of the Vermont Castings Defiant Model 1610 non-catalytic wood burning heater. This heater meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold on or after July 1, 1990. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 9,700 to 26,600 Btu/hr.
The Defiant Model #1610 has been tested and is listed by OMNI-Test Laboratories of Beaverton, Oregon. The test standards are ANSI/UL-1482 and ANSI/UL-737 for the United States, and ULC S627 for Canada. The Defiant is listed for burning wood only. Do not burn other fuels. The Defiant is not approved for use in manufactured (mobile) homes.
We recommend that you hire a professional installer certified by the Wood Heat Education and Research Foundation (WHERF) or the Wood Energy Technical Training (WETT) to install your stove, or to advise you on the installation should you attempt to install it yourself.
Please read this entire manual before you install and use your new stove. Failure to follow instructions may result in property damage, bodily injury, or even death.
Save These Instructions for Future Reference
2
30002850
Defiant 1610 Non-Catalytic Woodburning Stove
The Story of the Defiant
No wood-burning appliance, save for Ben Franklin’s Pennsylvania Fireplace, has a stronger heritage than the Ver­mont Castings Defiant. Named for a 19th-century steamship, the original Vermont Castings Defiant Wood Stove came to epitomize America’s resolve and independence during the Energy Crisis of the 1970s.
The year was 1975. With energy prices going through the roof, without an attractive or efficient wood stove to be found anywhere, two entrepreneurs set out to create a stove that was both beautiful and highly functional. Finely crafted from cast iron, the Defiant was the first wood stove to combine an artistically designed exterior with a methodi­cally engineered interior, using new technologies for efficient combustion.
Americans purchased over a quarter-million Defiants, as they rediscovered the common sense of heating with wood, a home-grown fuel with none of the political and economic entanglements of foreign oil.
Thirteen years later, in 1988, Vermont Castings ‘retired’ the Defiant, replacing it with modern wood-burners such as the Encore.
With its 1998 return, a new Defiant incorporated all the finest aesthetic, convenience, and performance features to be found on any wood stove. After continued development, this Defiant model 1610 non-catalytic model continues the tradition of the original Defiant while incorporating the very latest combustion technology. In a sense, the new Defiant has been 23 years in the making.
Due to its significant role in American history, the original model Defiant is in the permanent collection of the Smithso nian Institution. Each new purchase of the Defiant stove continues that history.
-
Table of Contents
Specifications .................................................4
Installation ......................................................5
Clearance Charts ......................................... 14
Assembly ...................................................... 20
Operation ......................................................22
Draft Management ........................................28
Maintenance ................................................. 31
Parts Diagram .............................................. 35
Warranty .......................................................
Proposition 65 Warning: Fuels used in gas, wood­burning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6
39
Installation Accessories
Warming Shelf #0210 Classic Black #0211 Biscuit #0212 Midnight Blue #0213 Ebony #0214 Bordeaux #0215 Chestnut Brown #0216 Vt. Classic Green #3265 Outside Air Kit #1907 Firescreen #1860 6” x 12” Oval Starter Pipe #2767 Fan Kit #0178 Flue Collar Heat Shield #0168 Connector Pipe Heat Shield
A line of porcelain enamel stove pipe is available in Biscuit, Bordeaux, Chestnut Brown, Ebony, Midnight Blue, Vt.Classic Green colors.
30002850
3
Defiant 1610 Non-Catalytic Woodburning Stove
D E F I A N T
32"
(822 mm)
28
"
(733 mm)
31"
(800 mm)
5"
(130 mm)
19"
(483 mm)
18"
(457 mm)
23"
(603 mm)
29"
(759 mm)
D E F I A N T
23"
(600 mm)
19"
(483 mm)
26"
(660 mm)
C
L
28"
(733 mm)
Rear Venting
Specifications
Defiant, Model 1610
EPA Emissions rating ................................... 0.75 g/hr*
Range of heat output ........... 10,000 to 30,300 BTU/hr.*
Maximum heat output .........................60,000 BTU/hr.**
Area heated .........................Up to 2,400 Square feet***
Fuel length ................................................................24”
Fuel capacity .............................. 50 pounds, hardwood
Loading .....................................................Front and top
Chimney Connector:
for 8” flue collar .................... 8” (203 mm) diameter
Chimney Flue Size: with 8” Chimney Connector ..8” (203 mm) minimum with 6” Chimney Connector ..6” (152 mm) minimum
Flue exit position ........................................ Top or Rear
Primary Air ...............................................Manual contol
Secondary Air ...............................Fixed, self-regulating
Ash handling system .....................Removable ash pan
Glass panels ........................ High-temperature ceramic
Weight ............................................... 490 lbs. (222 kg.)
Width (leg to leg) .................................. 32³⁄₈” (822 mm)
Depth (leg to leg) ..................................... 19” (483 mm)
Height to top of flue collar ..................... 29⁷⁄₈” (759 mm)
*Under specific conditions during EPA emissions test­ing.
** This value can vary depending on how the stove is operated, the type and moisture content of the fuel used, as well as the design, construction and climatic location of your home. Figures shown are based on maximum fuel consumption rates obtained under labo­ratory conditions and on average efficiencies.
*** These values are based on operation in building code-conforming homes under typical winter climate conditions in New England. If your home is of nonstan­dard construction (e.g. unusually well insulated, not in­sulated, built underground, etc.) or if you live in a more severe or more temperate climate, these figures may not apply. Since so many variables affect performance consult your Authorized Dealer to determine realistic expectations for your home.
Drawing Not to Scale
Fig. 1 Defiant NC dimensions.
4
30002850
Defiant 1610 Non-Catalytic Woodburning Stove
30
25
20
15
0 2000 4000 6000 8000 10000 12000
Height
Altitude
Installation
SAFETY NOTICE: IF YOUR DEFIANT IS NOT PROP­ERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC­TIONS AND INSTALLATION INSPECTION REQUIRE­MENTS IN YOUR AREA.
Before you begin an installation, be sure that:
Your stove and chimney connector will be far
enough from combustible material to meet all clear­ance requirements.
The floor protector is large enough and is construct-
ed properly to meet all requirements.
You have all necessary permits from local authori-
ties.
Your local building official is the final authority for ap­proving your installation as safe and determining that it meets local and state codes.
The metal label permanently attached to the back of every Vermont Castings’ stove indicates that the stove has been tested to current UL and ULC standards, and gives the name of the testing laboratory. Clearance and installation information also is printed on the label. When the stove is installed according to the information both on the label and in this manual, local authorities usually will accept the label as evidence that the instal­lation meets codes and can be approved.
However, codes vary in different areas. Before starting the installation, review your plans with the local building authority. Your local dealer can provide any additional information needed.
For any unresolved installation issues, refer to the National Fire Protection Association’s publication ANSI/NFPA 211 Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances. For Canada, the equivalent publication is CSA CAN-B365 Installation Code for Solid Fuel Burning Appliances and Equipment. These standards are the basis for many national codes. They are nationally recognized and are accepted by most local authorities. Your local dealer or your local
building official may have a copy of these regulations.
IMPORTANT: Failure to follow these installation instructions may result in a dangerous situation, in­cluding a chimney or house fire. Follow all instruc­tions exactly, and do not allow makeshift compro­mises to endanger property and personal safety.
Outside Air
In some modern, super-insulated homes, there may be inadequate air supply for combustion because of insuf­ficient air infiltration into the building. Such air enters a home through unsealed cracks and openings. Exhaust fans in kitchens or bathrooms can compete with the stove for available air and compound the problem.
When poor draft is caused by a low infiltration rate, opening a ground floor window on the windward side of the house and near the stove will usually alleviate the problem.
A better solution is to install a permanent outside air supply to the stove and/or room. In fact, bringing air for combustion from outside the home directly to the air inlet of the stove is required for new construction in some areas. The Defiant NC stove is equipped with an outside air connection as standard equipment.
Pressure variations within the house do not affect a stove equipped with an outside air supply, and im­proved stove performance often results. An Outside Air Kit for the Defiant is available from your local dealer.
Chimney Height
Altitude affects chimney performance. When using an 8” oval to 6” flue collar adapter on the Defiant, refer to Figure 1 for suggested chimney heights at various altitudes. Chimney height should be measured from the flue collar to the top of the chimney. The recommended minimum chimney height is 16 feet (5 meters).
ST491
Fig. 2 Chimney height requirements with 6” chimney and/or chimney connector.
30002850
5
Defiant 1610 Non-Catalytic Woodburning Stove
2' Min.
2' Min.
3'
Min.
0 To 10'
3'
Min.
0 To 10'
What Kind of Chimney to Use
You must connect the Defiant to a code-approved masonry chimney with a flue liner, to a relined masonry chimney that meets local codes, or to a prefabricated metal chimney that complies with the requirements for Type HT chimneys in the Standard for Chimneys, Factory-Built, Residential Type and Building Heating Appliance, UL 103. Figure 3 illustrates the two types. The chimney and chimney connector must be in good condition and kept clean.
If you use an existing masonry chimney, it must be inspected to ensure it is in a safe condition before the stove is installed. Your local professional chimney sweep, building inspector, or fire department official will be able to inspect the chimney or provide a refer­ral to someone who can. See “Chimney and Fireplace hazards”, in the appendix, for particulars.
A prefabricated double­wall insulated chimney
Masonry Chimneys
An inspection of the chimney must confirm that it has a lining. Do not use an unlined chimney. The chimney should have no cracks, loose mortar, other signs of deterioration, and blockage. Repair any defects before the chimney is used with your stove.
Unused openings in an existing masonry chimney must be sealed with masonry to the thickness of the chimney wall, and the chimney liner should be repaired. Open­ings sealed with pie plates or wallpaper are a hazard and should be sealed with mortar or refractory cement. In the event of a chimney fire, flames and smoke may be forced out of these unused thimbles.
The chimney should be thoroughly cleaned before use.
A newly-built masonry chimney must conform to the standards of your local building code or, in the absence of a local code, to a recognized national code. Mason­ry chimneys must be lined, either with code-approved masonry or pre-cast refractory tiles, stainless steel pipe, or a code-approved, “poured-in-place” liner. The chimney’s clean-out door must seal tightly. A loose or leaky clean-out door can weaken chimney draft, caus­ing performance problems.
A tile-lined masonry chimney
ST241
Fig. 3 Approved chimney types.
The chimney must extend at least 3’ (914 mm) above the highest point where it passes through or near a roof, and at least 2’ (610 mm) higher than any part of a building within 10’ (3 m) horizontally. (Fig. 4)
For proper draft and good performance, any chimney used with a Defiant should extend at least 16’ (5 m) above the flue collar of the stove.
Reference Point
Fig. 4 The 2’-3’10’ Chimney Rule.
AC617
6
Prefabricated Chimneys
A prefabricated metal chimney must be one tested and listed for use with solid-fuel burning appliances to the High-Temperature (H.T.) Chimney Standard UL-103­1985 (2100°F) for the United States, and High Temper­ature (650°C) Standard ULC S-629 for Canada.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
Chimney Size
A Defiant with an 8” (203 mm) flue collar is approved for venting into a masonry chimney with a nominal flue size of 8” x 8” (203 x 203 mm) or 8” x 12” (203 x 305 mm), and into a round flue with nominal flue size of 8” (203 mm). A Defiant with a 6” (152 mm) flue connector is approved for venting into a masonry chimney with a nominal flue size of 8” x 8” (203 x 203 mm), and into a round flue with nominal flue of 6” (152 mm).
NOTE: When installed with a 6” flue collar, the Defi­ant may not be operated with the front doors open.
Whatever the flue collar size, a Defiant may be vented into larger chimneys as well. However, chimneys with liners larger than 8” x 12” (203 x 305 mm) may experience rapid cooling of smoke and reduction in draft, especially if the chimneys are located outside the home. These large chimneys may need to be insulated or have their flues relined for proper stove performance.
30002850
Defiant 1610 Non-Catalytic Woodburning Stove
Accessories to help make the connection between stainless steel chimney liners and your Defiant are available through your local dealer.
Chimney Connector Guidelines
A chimney connector is the single-wall pipe that con­nects the stove to the chimney. The chimney itself is the masonry or prefabricated structure that encloses the flue. Chimney connectors are used only to connect the stove to the chimney.
Single-wall connectors should be made of 24 gauge or heavier steel. Do not use galvanized connector; it cannot withstand the high temperatures that can be reached by smoke and exhaust gases, and may re­lease toxic fumes under high heat. The connector may be 6” (152 mm) or 8 “ (203 mm) in diameter.
If possible, do not pass the chimney connector through a combustible wall or ceiling. If passage through a com­bustible wall is unavoidable, refer to the section on Wall Pass-Throughs. Do not pass the connector through an attic, a closet or similar concealed space. The whole connector should be exposed and accessible for in­spection and cleaning.
In horizontal runs of un shielded chimney connector, maintain a distance of 30” (762 mm) from the ceiling. Keep it as short and direct as possible, with no more than two 90° turns. Slope horizontal runs of connector upward 1/4” per foot (6mm per meter) going from the stove toward the chimney. The recommended maxi­mum length of a horizontal run is 3’ (1 m), and the total length should be no longer than 8’ (2.4 m). In cathedral ceiling installations, extend the prefabricated chimney downward to within 8’ (2.4 m) of the stove. This will help maintain a good draft by keeping the smoke warm, so that it rises readily.
Wear gloves and protective eyewear when drilling, cut ting or joining sections of chimney connector.
-
Single-wall Chimney Connectors
Begin assembly at the flue collar of the stove. Insert
the first crimped end into the stove’s flue collar, and keep each crimped end pointing toward the stove. (Fig. 5) Using the holes in the flue collar as guides, drill 1/8” (3mm) holes in the bottom of the first sec­tion of chimney connector and secure it to the flue collar with three #10 x 1/2” sheet metal screws. Lift off the griddle, and shield the stove’s surface between the griddle opening and the front of the flue collar to protect the finish when you drill the front hole.
Fasten each joint between sections of chimney
connector, including telescoping joints, with at least three (3) sheet metal screws. The pre-drilled holes in the top of each section of chimney connector serve
as guides when you drill 1/8” (3mm) holes in the bot­tom of the next section.
Fasten the chimney connector to the chimney.
Instructions for various installations follow. Figure 6 illustrates the general layout of chimney connector parts.
Be sure the installed stove and chimney connector
are correct dis­tances from nearby combustible materi­als.
NOTE: Special slip pipes and thimble sleeves that form tele­scoping joints between sections of chimney connector are avail­able to simplify instal­lations. They often eliminate the need to cut individual con­nector sections. Consult your local dealer about these special pieces.
Toward Stove
Flue Gas Direction
ST242
Fig. 5 Chimney connector.
Securing the Single-wall Connector to a
Prefabricated Chimney
Follow the installation instructions of the chimney manufacturer exactly as you install the chimney. The manufacturer of the chimney will supply the acces­sories to support the chimney, either from the roof of the house, at the ceiling of the room where the stove is installed, or from an exterior wall.
Special adapters are available from your local dealer to make the connection between the prefabricated chimney and the chimney connector. The top of such adapters attaches directly to the chimney or to the chimney’s ceiling support package, while the bottom of the adapter is screwed to the chimney connector.
These adapters are designed so the top end will fit out­side the inner wall of the chimney, and the bottom end will fit inside the first section of chimney connector.
Securing the Single-wall Connector to a
Masonry Chimney
Both freestanding masonry chimneys and fireplace ma­sonry chimneys may be used for your installation.
Freestanding Installations
If the chimney connector must pass through a combus­tible wall to reach the chimney, follow the recommen­dations in the Wall Pass-Through section that follows. The opening through the chimney wall to the flue (the “breech”) must be lined with either a ceramic or metal cylinder, called the “thimble”, which is cemented
30002850
7
Defiant 1610 Non-Catalytic Woodburning Stove
DE FI AN T
*
*
Chimney
Elbow
Flue
Flue In­ner
Without a thimble, a suitable length of chimney con­nector can be extended through the breech to the inner face of the flue liner, and cemented securely in place. Additional pieces of connector are then attached with
sheet metal screws.
Slip Pipe
Standard Connector
Oval to Round Adapter
Flue Collar
Fig. 6 An exploded view of the chimney connection in a free­standing masonry installation.
Thimble
ST492
securely in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the joint between the thimble and the chimney wall must be cemented firmly.
A special piece called the “thimble sleeve,” slightly smaller in diameter than standard connectors and most thimbles, will facilitate the removal of the chimney connector system for inspection and cleaning. (fig. 7) Thimble sleeves are available from your local dealer.
To install a thimble sleeve, slide it into the breech until it is flush with the inner flue wall. Do not extend it into the actual flue passage, as this could interfere with the draft.
Fireplace Installations
The chimney connector may be connected to the chimney above the fireplace opening or through the fireplace.
Above the Fireplace
The Defiant may be connected to a chimney above a fireplace opening. (Fig. 8) In such installations, the stove is positioned on the hearth in front of the fireplace and the chimney connector rises from the stove top and then angles ninety degrees back into the chimney. The chimney liner should extend to the point at which the chimney connector enters the chimney.
Check These Clearances
Mantel
Seal This Off
Thimble Sleeve
Flue
Chimney Connector
Keep sleeve end flush with flue tile
ST243
Fig. 7 The thimble, made of either ceramic or metal, must be cemented securely in place.
The thimble sleeve should protrude 1-2” (25-50 mm) into the room. Use furnace cement and thin gasketing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws.
8
ST244a
Fig. 8 In this installation, the chimney connector attaches to the chimney above the fireplace opening.
If the chimney connector in your installation enters the chimney above a fireplace, follow all the guidelines mentioned above for freestanding installations. In addi­tion, give special consideration to the following points:
Check the clearance between the stove and the
chimney connector, and any combustible trim or the mantel.
Check the clearance between the chimney connec-
tor and the ceiling. The clearance should be at least 30” (762 mm) with unshielded connectors. Consult the clearance charts for other installation options.
The fireplace damper must be sealed to prevent
room air from escaping up the flue. However, it
30002850
Defiant 1610 Non-Catalytic Woodburning Stove
D
E
F
I
A
N
must be possible to re-open the damper to inspect or clean the chimney.
Through the Fireplace
If your fireplace opening height is at least 29" (737 mm), you may install a Defiant through the opening using a “positive connection” kit, available from your local deal­er. Positive connection kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig. 9)
Fireplace installations, whether connected to the flue above or through the fireplace opening, have special clearance requirements to adjacent trim and the mantel. You’ll find the required safe clearances for Defiant fire place installations on Page 12.
Floor protection requirements also apply to fireplace installations. This information is on Page 10.
Flexible Connector
-
Figure 10 shows one NFPA-recommended method. All combustible material in the wall is cut away from the single-wall connector to provide the required 12” (305 mm) clearance. Any material used to close up the open­ing must be noncombustible.
Wall Stud
Chimney Connector
12” of Noncombustible Material
Floor Protec­tion
ST493
Mantel Shield
Fireplace Adapter Kit “Positive Connection”
ST245
Fig. 9 Through the fireplace installation.
Wall Pass-Throughs
Whenever possible, design your installation so the con­nector does not pass through a combustible wall. If you are considering a wall pass-through in your installation, check with your building inspector before you begin. Also, check with the chimney connector manufacturer for any specific requirements.
Accessories are available for use as wall pass­throughs. If using one of these, make sure it has been tested and listed for use as a wall pass-through.
In the United States, the National Fire Protection As­sociation (NFPA) has established guidelines for passing chimney connectors through combustible walls. Many building code inspectors follow these guidelines when approving installations.
Fig. 10 An approved wall pass-through for the United States.
Three other methods are also approved by the NFPA:
Placing a section of chimney connector inside a
ventilated thimble, which in turn is separated from combustibles by 6” (152mm) of fiberglass insulating material.
Placing a section of chimney connector inside a
section of 9” (230mm) diameter, solid-insulated, factory-built chimney, with 2” (50mm) of air space between the chimney section and combustibles.
Using a section of solid-insulated double-wall high
temperature chimney, with an inside diameter the same as the chimney connector, at least one inch of solid insulation, and a minimum of 9” (229 mm) air space between the outer wall of the chimney section and combustibles.
In Canada, The Canadian Standards Association has established different guidelines for wall pass-throughs. Figure 11 shows one method, in which all combustible material in the wall is cut away to provide the required 18” (457mm) clearance for the connector. The resulting space must remain empty. A flush-mounted sheet metal cover may be used on one side only. If covers must be used on both sides, each cover must be mounted on noncombustible spacers at least 1” (25mm) clear of the wall.
30002850
9
Defiant 1610 Non-Catalytic Woodburning Stove
D
E
F
I
A
N
T
18” (460mm) clear­ance between pipe and sides/top/bottom of opening
ST494
Fig. 11 An approved wall pass-through for Canada.
Your local dealer or your local building inspector can provide details for other approved methods of passing a chimney connector through a combustible wall in your area. In Canada, this type of installation must conform to CAN/CSA-B365, Installation Code for Solid Fuel Burning Appliances and Equipment.
NOTE: Do not vent your Defiant into a factory-built (zero-clearance) fireplace. These appliances and their chimneys are specifically designed as a unit for use as fireplaces. It may void the listing or be hazardous to adapt them for any other use.
DO NOT CONNECT THE DEFIANT TO ANY AIR DIS­TRIBUTION DUCT OR SYSTEM.
Floor Protection
A tremendous amount of heat radiates from the bottom plate of your stove. The floor area directly under and around the stove will require protection from radiant heat as well as from stray sparks or embers that may escape the firebox.
Heat protection is provided with the use of the Bottom Heat Shield and ash door heat shield supplied with the stove.
Most installations will require the bottom heat shield to be attached. Only when the stove is placed on a completely noncombustible surface such as unpainted concrete over earth may it be used without the heat shield.
Even when the bottom heat shield and ash door heat shields are installed, most installations require special thermal protection (insulation) for the floor beneath. Use an approved 1/2” (13 mm) noncombustible hearth pad with k = 0.84 BTU/in ft2 hr °F or an equivalent material with an R-value of at least 0.59. (Refer to “How to Determine if Alternate Floor Protection Materials are Acceptable” section.) The floor protector may be covered with a decorative noncombustible material if desired. Do not obstruct the space under the heater.
10
NOTE: There is only one stove configuration that does not require thermal protection for a com­bustible floor. This is when the stove is installed using an 8” connector pipe and chimney AND when the provided ash door and bottom heat shield are installed. Spark and ember protection is still neces­sary even if insulated hearth pad is not used. Use 24 gauge sheet metal or other noncombustible ma­terial sized according to the instructions below. All other installations require the use of thermal floor protection as described above.
There is only one stove configuration where the supplied ash door heat shield is not required over a combustible floor. This is when the stove is vented with an 8” connector and chimney AND thermal protection is installed as described above.
Important: All installations on a combustible floor require the use of the supplied bottom heat shield. This is true whether or not extra thermal protection (insulation) is installed.
Protection requirements vary somewhat between the Untied States and Canada as follows:
In U. S. installations the floor protector is required under the stove and must extend at least 16” (not including the ash lip) from the front of the stove (“F”, Fig. 12), and at least 6” from the sides and rear. (“D” and “E”, Fig. 12)
In rear venting configurations, floor protection must also extend under the chimney connector and 2” to either side. (“C”, Fig. 12) For the 8” (203 mm) connector, the protector must be a minimum of 12” (305 mm) wide. For the 6” (152 mm) connector, the protector must be 10” (254 mm) wide. The protector must be centered under the connector.
To meet these requirements, a floor protector must be at least 44” wide and 46” deep.
In Canada: A noncombustible floor protector is required under the stove as well. The floor protector must extend 18” (457 mm) to the front (“F”, Fig. 12), and 8” (203 mm) from the sides and rear. (“D” and “E”, Fig. 12)
To meet these requirements, a floor protector must be at least 46” (1168 mm) wide and 50” (1270 mm) deep.
How to Determine if Alternate Floor Protection Materials are Acceptable
All floor protection must be noncombustible (i.e. met­als, brick, stone, mineral fiber boards, etc.). Any organic materials (i.e. plastics, wood paper products, etc.) are combustible and must not be used. The floor protection specified includes some form of thermal designation such as R-value (thermal resistance) or k-factor (ther­mal conductivity).
30002850
Defiant 1610 Non-Catalytic Woodburning Stove
D
E
A
B
A
E
C
E
F
E
F
Step c: Compare proposed system Rtotal of 1.231 to
specified R of 0.59. Since proposed system Rtotal is greater than required, the system is acceptable.
Definitions
R =
(ft2)(hr)(°F)
Btu
k = = K x 12
(Btu)(in)
(ft2)(hr)(°F)
K =
(Btu)(ft)
(ft2)(hr)(°F)
(ft2)(hr)(°F)
r = =
(Btu)(in)
1 k
Floor Protection for Fireplace Installation
U.S. Canada
A. 44” 48” (1219 mm) B. 46” 50” (1270 mm) C. 12” 12” (305 mm) 8” Connector 10” 10” (250 mm) 6” Connector D. 6” 8” (203 mm) E. 6” 8” (203 mm) F. 16” 18” (460 mm)
Fig. 12 Required floor protection dimensions.
ST500
Procedure:
1. Convert specifications to R-value:
i. R-value given - no conversion needed. ii. k-factor is given with a required thickness (T) in
inches:
1
R = x T
k
iii. K-factor is given with a required thickness (T) in
inches:
R = x T
1
K x 12
iv. r-factor is given with a required thickness (T) in
inches: R = r x T
2. Determine the R-value of the proposed alternate floor protector:
i. Use the formula in Step 1 to convert values not
expressed as R.
ii. For multiple layers, add R-values of each layer to
determine overall R-value.
3. If the overall R-value of the system is greater than the R-value of the specified floor protector, the alter
-
nate is acceptable.
EXAMPLE: The specified floor protector should be 1/2­inch thick material with k-factor of 0.84. The proposed alternate is 4” brick with an r-factor of 0.2 over 1/8” mineral board with a k-factor of 0.29
Step a: Use formula above to convert specification to
R-value:
1
R = x T = x 0.5 = 0.59
k
1
0.84
Step b: Calculate R of proposed system. 4” brick of r = 0.2, therefore: R
= 0.2 x 4 = 0.8
brick
1/8” mineral board of k = 0.29, therefore R
mineralboard
R
total
= R
1
= x 0.125 = 0.431
0.29
+ R
brick
mineralboard
= 0.8 + 0.431 = 1.231
30002850
Do not assume that your fireplace hearth is completely noncombustible. Many fireplace hearths do not satisfy the “completely noncombustible” requirement because the brick or concrete in front of the fireplace opening is supported by heavy wood framing. Because heat passes readily through brick or concrete, it can easily pass through to the wood. As a result, such fireplace hearths can be a fire hazard and are considered a com­bustible floor.
For all fireplace installations, follow the floor protec­tion guidelines described above, including the need for bottom and ash door heat shields. Keep in mind that many raised hearths will extend less than the required clearance from the front of the heater. In such cases, sufficient floor protection as described above must be added in front of the hearth to satisfy the minimum floor protector requirement from the front of the stove: 16” (410 mm) in the United States and 18” (460 mm) in Canada. Hearth rugs do not satisfy the requirement for floor protection as they are not fire proof.
Fireplace installations also have special clearance requirements to the side walls, side decorative trim and fireplace mantel. Refer to the information on fireplace and mantel trim shields in this section.
Keep the Stove a Safe Distance
From Surrounding Materials
Both a stove and its chimney connector radiate heat in all directions when operating, and nearby combustible materials can overheat dangerously if they are too close to the heat source. A safe installation requires that ad­equate clearance be maintained between the hot stove and its connector and nearby combustibles.
Clearance is the distance between either your stove or chimney connector, and nearby walls, floors, the ceiling, and any other fixed combustible surface. The Defiant has specific clearance requirements that have been established after careful research and testing. These clearance requirements must be strictly observed.
In addition, keep furnishings and other combustible materials away from the stove. In general, a distance of 48” (1219 mm) must be maintained between the stove and moveable combustible items such as drying
11
Defiant 1610 Non-Catalytic Woodburning Stove
1" (25mm)
1/4" (6mm)
clothes, furniture, newspapers, firewood, etc. Keep­ing those clearance areas empty assures that nearby surfaces and objects will not overheat.
Safe Ways to Reduce Clearances
Clearance requirements are established to meet every installation possibility, and they involve the combination of these variables:
When the stove pipe has no listed heat shield
mounted on it.
When the wall has no heat shield mounted on it.
When the wall has a heat shield mounted on it.
When the wall and stove pipe have heat shields.
In general, the greatest clearance is required when you place a stove and its connector near a wall with no heat shield.
For example, when the Defiant is installed parallel to the rear wall with 8” pipe and no connector shield is used, it must be at least 35” (889 mm) from the wall behind it and at least 23” (584 mm) from walls on either side. These dimensions are measured from the top edge of the stove to the combustible wall.
If the Defiant is installed in a corner and no shield is used, the corners of the stove top must be at least 25” (635 mm) from nearby walls when using 8” connector pipe.
Clearances may be reduced only by means approved by the regulatory authority, and in accordance with the clearances listed in this manual. Refer to Pages 10 - 13 for approved clearance reduction specifications.
NOTE: Clearance requirements differ for 8” and 6” con­nector pipe installation. A minimum ceiling height of 8 feet (2.4 m) is required for all installations of the Defiant NC.
NOTE: Installation of the Defiant is not permitted in alcoves.
Wall Shields
One way to reduce clearances is with a wall shield constructed of 24 gauge or heavier sheet metal, or of another noncombustible material such as 1/2” (13 mm) insulation board such as Durock® or Wonderboard®, or common brick “laid on flat,” with the 3¹⁄₂" (90 mm) side down.
Shields must be spaced out from the combustible surface 1" (25 mm) on noncombustible spacers, as in Figure 13. The spacers should not be directly behind the stove or chimney connector.
Air must be able to flow between the wall and the shield. At least 50% of the bottom 1" (25 mm) of the shield must be open, and the shield must be open at the top. Metal screening across the top will keep small stray objects from being trapped behind the shield. (Fig.
13)
With 6” connections and chimneys, the shield must be a minimum of 48" (1219 mm) tall, and must extend at least 19" (483 mm) higher than the top of the stove, whichever is higher. The shield behind the chimney connector must be 30" (760 mm) wide, centered behind the pipe; for installations that use an approved prefab­ricated chimney to pass through the ceiling, the shield behind the chimney connector must stop 1" (25 mm) below the ceiling.
With 8” connections and chimneys, because of poten­tially higher pipe temperatures, the shield must extend the full height of the wall (up to 9’ (2.7 m)) and stop 1” (25 mm) below the ceiling.
Air Flow
Screen
Wall Shield
Stud Wall Framing
Noncombus­tible Spacers and Fasteners
Drywall
Air Flow
Fig. 13 Approved wall shield construction.
Shield
Metal Spacer
ST248
Fireplace and Mantel Trim Shields
A fireplace installation requires special clearance between the side of the stove and the right and left walls, between the side of the stove and the decorative side trim on the fireplace face, and between the top of the stove and the mantel.
Noncombustible shields installed 1” (25 mm) away from the combustible surface on noncombustible spacers, called ventilated shields, may be used to reduce clearances.
To protect a mantel from the heat of a stove in a fireplace installation, use a custom­made ventilated mantel shield that is at least 48” (1220 mm) long, centered over the stove. (Fig. 14) Ventilated shields for side trim must extend the full length of the trim.
ST501
Fig. 14 A custom-formed mantel shield.
12
30002850