No part of this publication covered by the copyrights herein may be
reproduced or copied in any form or by any means — graphic,
electronic, or mechanical, including photocopying, taping, or
information storage and retrieval systems — without written permission
of the publisher.
The content of this document is subject to change without notice. The
information contained herein does not represent a commitment on the
part of VeriFone, a division of Hewlett-Packard.
Publications are not stocked at the address given above. Requests for
VeriFone publications should be made to your VeriFone representative.
VeriFone is a registered trademark of Hewlett-Packard Company. All
other products mentioned in this manual are tradem arks or registered
trademarks of their respective owners.
VeriFone Indoor VeriPASS
Terminal Installation Guide
Revision History
RevisionDateComments
AAugust 15, 1999Initial release of software
and documentation.
FCC Compliance
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
■
Reorient or relocate the receiving antenna.
■
Increase the separation between the equipment and
receiver.
■
Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
■
Consult the dealer or an experienced radio/TV technician
for help.
Safety Instructions
■
Read all instructions contained in this guide be fore making
any equipment connections.
■
Save these instructions for later use.
■
Unplug the unit before servicing or cleaning. Do not use
liquid or aerosol cleaners. Use only a damp cloth for
cleaning.
■
Do not use any attachments not specifically recommended
by VeriFone as they may result in the risk of fire, electric
shock, or injury to persons.
■
Do not use the unit near water.
■
Do not place the unit on an unstable cart, stand, or table.
The unit may fall, causing serious personal injury and/or
damage to the equipment.
This document provides the information necessary to install your
VeriFone Indoor VeriPASS Terminal System.
mobilind.wmf 125%
VeriFone Indoor
VeriPASS Terminal
Introduction
Everest
Base Cable
Ferrite Bead
Base Unit
Cable Tie
Installation
Manual
Multicable
Optional Power Supply*
(VFI P/N: 04250-05)
* Optional Power Supply not required
when used with a Ruby SuperSystem
The VeriFone Indoor VeriP ASS Terminal System is a self-contained
device, when properly installed, becomes an integral part of the
Ruby SuperSystem. It has the ability to read a retail customer’s tag
when placed near an antenna mounted on the face of the equipment.
Information from the tag is processed and transferred to the Ruby.
Introduction ◆
1
◆ Introduction
2
2
Carefully inspect the shipping carton and its contents for any
damage that may have occurred during shipment. If anything
appears damaged, immediately file a claim with the shipping
company or carrier and notify your VeriFone representative.
Warning:Never use damaged equipment. A shock or fire
Remove the following items from the shipping carton:
Remove any protective plastic wrapping from the components and
place the components on a table or countertop.
Retain the shipping carton and any packing material in case it is
necessary to move components from one location to another or to
return the equipment for service.
Unpacking
hazard may exist if equipment is energized in a
damaged condit ion.
VeriFone Indoor VeriPASS Terminal Unit with attached
■
Mulitcable
Power Supply (opt io nal )
■
Ferrite Bead
■
Unpacking ◆
3
◆ Unpacking
4
3
Unpack equipment in accordance with instructions listed in Chapter
2.
Warning:To reduce the risk of fire, do not place this unit near
When selecting a location for your VeriFone Indoor VeriPASS
Terminal equipment, avoid areas having:
Installation
any heat producing source.
Direct sunlight or objects that produce heat.
■
Moist areas.
■
Excessive dust.
■
Electrical “noise” or devices that cause excessive voltage
■
variations such as air con diti oners, f ans, or high fr equenc y
security systems.
Installation Procedures
Note:If not present, install the Ferrite Bead on the
Multicable, as close to the Base Unit as possible. This
filters out any interference generated by the
equipment. Refer to the diagram on page 1 for
location.
Use the following procedure to install and power up the VeriFone
Indoor VeriPASS Terminal in a VFI Ruby environment.
Installation ◆
5
1.Ensure power to the Ruby is disconne cted
2.Place the unit close to the Ruby.
3.Uncoil the Multicable and ensure that it does not kink or is
not placed under heavy equipment.
4.Mount the unit on a custom stand, if applicable.
5.Insert the RS232 cable connector from the Ruby into the
Multicable jack labeled PORT 1.
6.Apply power to the Ruby.
Ferrite Bead
VeriFone
Indoor
VeriPASS
Terminal
Multicable
Equipment Power Up
PORT 1
Serial C abl e
P/N: 13836-01
* Consult VASC Service Manual to
determine the correct com port for
your application.
Ruby
Com Port*
The Verifone VeriPASS Terminal is powered from the Ruby
T erminal through a serial cable. This feature eliminates the need for
an optional power supply.
Note:The VeriPASS Terminal may be powered by an
optional external power supply (VeriFone P/N:
04250-05).
Use the following procedures to power up the VeriFone Indoor
Veri PASS Terminal unit using the optional power supply:
◆ Installation
6
1.Insert the Power Cable connector into the Multicable jack
labeled POWER.
Note:Use a locally available cable tie to secure the Power
Cable jack to the Multicable connector as shown in
the diagram on page 1. This c onfiguration maintains
the integrity of the connection and provides additional
connection security.
Warning:When the optional Power Supply is plugged into th e
AC power outlet, voltage is immediately available to
the VeriFone Indoor VeriPASS Terminal. Avoid
handling the exposed power cable connector.
Note:The AC power outlet should be easily accessible
should the user desire quick power disconnect.
2.Connect the Power Supply to the AC power outlet or
appropriately configured power connector.
3.Verify the customer display is activated.
4.Verify the logo illum in a tes momentarily when power is
applied.
5.Verify the display is illuminated and the display is
activated.
Warning:To turn off your VeriFone Indoor VeriPASS Terminal,
always unplug the power supply from the AC power
outlet first. This eliminates the presence of voltage at
the Multicable power receptacle and the potential
shock hazard.
Installation ◆
7
◆ Installation
8
4
Specifications
Power Requirements
Input: 120VAC 60Hz 18 W
■
Output: 12VDC 1000 mA
■
Operating Environment
Temperature: 0 to 40oC (32 to 104oF)
■
Humidity: 20% to 90%, noncondensing
■
Service and Repair
Do not, under any circumstances, attempt to repair, service, or
adjust your VeriFone Indoor VeriPASS Terminal equipment . If yo u
have any problems with your unit, contact your VeriFone
Authorized Service Contractor.
Note:Changes or modifications not expressly approved by
VeriFone could void the user's authority to operate
this equipment.
Specifications ◆
9
Cleaning
Warning:Disconnect power before cleaning this equipment.
Routine cleaning can be accomplished by removing dust or dirt
with a clean, damp cloth and mild soap or detergent. Use a cloth
dampened with alcohol for more stubborn stains.
Warning:Never use thinner, trichloroethylene, or ketone based
solvents to clean this equipment or cabling as they
may deteriorate plastic parts.
◆ Specifications