Overview of the controls for the VMB1TC temperature controller (rev. 4)
2
Location
5
Living
Ma 14:23 21
Mode
Menu
Direct control
Button Action
Location
Mode
’ ‘’ Menu
Modify sensor or zone. The previous/next room (zone) can be selected with the ““ or “” button as long as the LED of these buttons blinks.
Temporarily switch between antifreeze -, night
, day or comfort
Remark: a long press will deactivate the temporary mode (sleep timer)
Display and/or modify desired temperature Short press: call abridged menu
Long press: call full menu
Menu control
Navigate through the menu with the “” and “↓” buttons. Select an item with the “” button. Confirm a setting with the “” button or clear the setting with the “” button. Quit the menu at any time without saving the modifications with the “5” button.
Short menu
Press the “Menu” button shortly to call the menu.
Sleep timer1
Temp. settings
Comfort Day temp Night temp To main menu
Alarm clock set
Clock set
Exit
Extended menu
Hold the “Menu” button pressed to call the extended menu. Enter the PIN code if necessary.
Program
Sensor Settings
Operating mode Button lock Sleep timer Low temp. alarm High temp. alarm Anti-freeze temp Upper heat temp Lower cool temp Upper cool temp Hysteresis Temp difference Unjam pump Unjam valve Local program
Zone number2 Diff. sensor2 Sensor cal. Change name3 To main menu
Configuration
Language Temp. Read-out Master clock Global alarm clk Battery backup Change PIN code Firmware version
Address2 Link wake-up2 Link go-to-bed2 Scan sensors2 To main menu
Display
Contrast Backlight To main menu
Statistics2
Min temp 16.0° Max temp 23.0°
- 0m/5m
0m/5m 8m/1h10m 10m/1h15m 18m/2h35m To main menu
Exit
Remarks:
1. This menu is only accessible if the temporary mode (sleep timer) is activated.
2. This menu is not accessible if a zone or “all rooms” are selected.
3. This menu is not accessible if “all rooms” are selected.