VMB1RY
Relay Module for
ELB
Velbus manual VMB1RY– edition 1 – rev.1.0
m
1
INDEX
Features ......................................................................................................................................... 3
Velbus data.................................................................................................................................... 4
Connection .................................................................................................................................... 5
Direct control with several push buttons.................................................................................. 6
Control via VELBUS system.................................................................................................... 6
Combination of direct push button control and VELBUS control............................................. 7
Use ................................................................................................................................................. 8
Termination ............................................................................................................................. 8
Addressing .............................................................................................................................. 9
Timer setting ........................................................................................................................... 9
Operation mode/ timer2 ..........................................................................................................9
Operation .............................................................................................................................. 11
LED indication....................................................................................................................... 11
Learning mode ...................................................................................................................... 11
Velbus manual VMB1RY– edition 1 – rev.1.0
2
Features:
◊ Relay output: changeover contact (N.O. and N.C.)
◊ Switching capacity with a resistive load: 16A/230Vac max.
◊ Switching capacity with an inductive load: 8A/230Vac max.
◊ Suppressed relay contacts.
◊ Manual control on the module
◊ LED indicators for:
• Relay output
• Operation modes (slow, fast, very fast or 2 x blinking and continuously ON)
• Power voltage
• Data reception and forwarding through VELBUS
◊ 10 different operation modes (adjustable through ‘mode’l rotary switch):
• Moment control
• On/off control
• Start/stop timer
• Staircase lighting timer
• Non-restartable timer
• Switch-off delay
• Switch-on delay
• Start timer by releasing push button
• Timer with blinking effect
• 2-way timer (short press will start timer 1/ long press will start timer2)
◊ 16 possible time settings (adjustable through ‘time1’ rotary switch): moment - 5s - 10s - 15s - 30s - 1min - 2 min
- 5min - 10min - 15min - 30min – 1h – 2h – 5h – 1day – on/off
◊ 9 possible time settings for timer 2 (adjustable through ‘time2’ rotary switch): 5min - 10min - 15min - 30min – 1h
– 2h – 5h – 1day – on/off
◊ Controllable by connecting several push buttons in parallel.
◊ Push button input debounce: 65ms.
◊ Control through VELBUS.
◊ Programmable without PC.
◊ Easy learning process by controlling the push buttons in the learning mode.
◊ 8 different control possibilities:
• Using push buttons turning on the relay.
• Using push buttons turning off the relay.
• Using push buttons turning the relay on or off.
• Using push buttons activating the set mode on the module.
• Using push buttons starting or stopping the timer.
• Using push buttons starting or stopping the 2nd timer.
• Using push buttons starting or restarting the timer.
• Using push buttons starting or restarting the 2nd timer.
◊ Memory for 7 different push buttons per command
◊ Learned push buttons are saved in case of a power failure.
◊ Report to control modules for LED status modification.
◊ 247 possible addresses (adjustable through ‘ADDR” rotary switch)
◊ Required power voltage: 12 to 18VDC
◊ Consumption in standby: 35mA at 18V (15mA at 16V)
◊ Consumption activated relay: 85mA at 18V (60mA at 16VDC)
◊ Max. consumption (activated relay and push button input): 100mA at 18V (75mA at 16VDC)
◊ Standard DIN-rail housing (2 modules)
◊ Dimensions (L x W x H): 90 x 36 x 58mm.
◊ Weight: 100g.
Velbus manual VMB1RY– edition 1 – rev.1.0
3
VELBUS:
2-wire communication for VELBUS data and 2 wires for power.
Data transfer: 16,6Kbit/s.
Serial data protocol: CAN (Controller Area Network)
Short-circuit proof (towards negative or positive of power)
Bus error indication: 2 x short flash of the operation mode led.
Self restoring after 25 seconds in case of a bus error.
Possibility to assign a name (max. 16 characters) which can be saved in the non-volatile memory.
The module can react to push button messages sent over the VELBUS.
A modification of the relay status will be reported on the VELBUS.
When modifying the relay status, the module will send instructions to adjust the status of the leds on the control
modules. Instructions will be accepted when calling up the module type, module name, module status, reading
from or writing to the non-volatile memory, switching on or off the relay and when starting or stopping the timer.
The module can respond with the module type, module name, module status or the contents from the memory.
.
Velbus manual VMB1RY– edition 1 – rev.1.0
4