4 independent relay contacts, 5A each
various timer possibilities per channel
pulse or toggle operation
can learn up to 31 transmitters
automated learning function for transmitters
use 32-bit code technology
more than 1.000.000.000 unique codes
open field range of up to 30m possible
SPECIFICATIONS
frequency: 433MHz
power supply: 230Vac
relay contacts N.O.: 5A (3A inductive load)
receiver dimensions: 108 x 102 x 45mm
WARRANTY : Th is product is guaranteed ag ainst defects in components and construction from th e moment it is purchased and for a p eriod of TWO YEAR starting from th e date of sale. This guarantee is onl y valid if the
unit is submitted together with t he original purchase inv oice. VELLE MAN components Ltd limits its responsi bility to the reparat ion of defects or, as VELLEMAN compon ents Ltd deems nec essary, to the replac ement or
reparation of d efective comp onents. Costs and risks con nected to the transport, rem oval or placement of the product , or any other costs directl y or indirectly con nected to the repair, will not be reimburs ed by VELLEMAN
components L td. VELLEMAN comp onents Ltd will not be held responsibl e for any damages c aused by the malf unctioning of a unit.
The transmitters VM160DT and VM160T comes with a factory set default code. However, for security reasons, it might be
wise not to use the default code.
Program your unique code :
1. Hold button "1"
2. Briefly press button "4" 3 times. The LED will flash 3 times.
3. Release button "1".
1 2
4. Your unique 32-bit code has been generated and stored.
4
1
2
3
4
Return to the default code :
1. Hold button "1"
2. Hold button "4". After +/- 10s the led will flash 5 times.
3. Release both buttons.
4. Your code has been erased.
3
4
Instructions for VM160
How to learn a remote?
1- Press and hold “Setup” button.
2- Press and hold remote channel 1 button.
3- All LEDs light = remote accepted.
4- Release “Setup” button.
How to set the output function for each channel?
Select a timer function between “Moment” and “On/
Off”. A function is indicated by LEDs 1 to 4 and
column LED*.
1- Press and hold “Setup” button.
To remove all remotes from memory :
On a transmitter:
2- Press channel 1 button repeatedly to
select function for channel 1.
3- Press channel 2 button repeatedly to
select function for channel 2.
4- Press channel 3 button repeatedly to
select function for channel 3.
5- Press channel 4 button repeatedly to
select function for channel 4.
6- Release “setup” button.
* Note: LED on = left column selection.
Turn off the power (disconnect power supply)
Hold 'setup' button
Turn on power (connect power supply)
Mode led will blink.
Release 'setup' when LED turns off
This process takes about 10 seconds.
If the button is released before the LED’s turn off, the memory will not be cleared.
The unit will now respond to the default code only >> please also reset the transmitter code.
Instructions
5
Eigenschappen en technische gegevens
Hartelijk dank voor de aanschaf van deze module.
Eigenschappen & technische gegevens
Optie:
EIGENSCHAPPEN
4 afzonderlijke relaiscontacten, elk 3A
meerdere timermogelijkheden per kanaal
impuls of schakeling
kan tot 31 zenders aanleren
automatische aanleerfunctie voor zenders
32-bit code technologie
meer dan 1.000.000.000 codes
bereik: tot 30m in open veld
TECHNISCHE GEGEVENS
frequentie: 433MHz
voeding: 230Vac
NO relaiscontacten: 5A (3A inductieve last)
afmetingen ontvanger: 108 x 102 x 45mm
WAARBORG
Dit produkt is gew aarborgd wat betr eft gebreken in mat erialen en vakm anschap op het ogen blik van de aank oop en dit gedurend e een periode van TWEE JAAR vanaf de aankoop. De w aarborg geldt enkel indien het
produkt voorg elegd wordt samen met het origin eel aankoop bewijs. De verplichtingen van VELLEMAN N.V. beperken zich tot het herstellen van defecten of, naar vrije keuze van VELLEMAN N.V., tot het vervangen of
herstellen van def ecte onderdelen. Kosten en risic o’s van transport; het wegnem en en terugplaatsen van het produ kt, evenals om het even welke ander e kosten die rechts treeks of onrechtstreeks ver band houden met de
herstelling, wor den niet door VELLEMAN N.V. ver goed. VELLEMAN N.V. is niet v erantwoordelijk voor sch ade van gelijk welke aard, veroo rzaakt door het falen van een pr oduct.
ZENDER
4 kanalen
frequentie: 433MHz
voeding: 12V-batterij (V23GA of GP23GAC)
afmetingen: 88 x 37 x 13mm
6
T
D
0
6
1
M
V
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.