VEGA HAN 8D User Manual

Supplementary instructions
Plug connector Harting HAN 8D
for
continuously measuring sensors

Content

1 For your safety
1.1 Appropriate
3
1.2 Impermissible use . . . . . . . . . . . . . . . . . . . . . .
3
1.3 General safety instructions . . . . . . . . . . . . . . . .
3
1.4 Safety instructions for Ex areas . . . . . . . . . . . .
3
2 Connecting to power supply
2.1 Wiring plan . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
3 Supplement
3.1 Technical data. . . . . . . . . . . . . . . . . . . . . . . . .
5
2 Plug connector Harting HAN 8D for continuously measuring sensors
Content
30376-EN-080307

1 For your safety

1.1 Appropriate use

P
lug connectors belong to the accessories for level, switching and pressure sensors. They provide a detachable connection to power supply/signal processing for two-wire sensors. Those are sensors whose power supply as well as measurement signal are transmitted over one pair of wires.

1.2 Impermissible use

As a rule, plug connectors are not allowed to be used with four­wire instruments. Those are sensors whose power supply and measurement signal are transmitted over two separate pairs of wires.

1.3 General safety instructions

The safety information in the operating instructions manual of the respective sensor must be noted.

1.4 Safety instructions for Ex areas

Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex­approved instruments.
For instruments with Exd or StEx approval, the use of plug connectors is not allowed.
Plug connector Harting HAN 8D for continuously measuring sensors 3
For your safety
30376-EN-080307

2 Connecting to power supply

2.1 Wiring plan

Each
respective wiring plan shows the assignment of the
individual pins of the plug connector depending on the signal output. The chart shows the assignment of the individual contact pins to the terminals of the sensor electronics.
4
3
5
1
2
678
21
8
Fig. 1: Top view of the plug connector 1 + (Pin 1) 2 - (Pin 2) 8 Screen (Pin 8)
Contact pin plug Colour, connection
cable
1)
Terminal, elec­tronics
Pin 1 Black 1
Pin 2 Blue 2
Pin 8 Green/yellow
1)
Instrument-internal, from plug to electronics module
4 Plug connector Harting HAN 8D for continuously measuring sensors
Connecting to power supply
30376-EN-080307

3 Supplement

3.1 Technical
data
Materials
Contact support Polyamide Contact copper alloy, hard silver plated 0.3 µm Ag Plug housing Aluminium die-casting Housing seal NBR
Temperature range
Plug connector - separate -25 +125 °C (-13 +257 °F) Plug - mounted on the sensor the lowest temperature is applicable
Electrical data
Operating current
2)
10 A
Reference
voltage 50 V
Isolation
resistor > 10000 Ω
Reference surge voltage 0.8 kV, 1.2 µs, 50 µs
Protection
Plug connector - separate (locked status)
IP 65 (with seal screw)
Plug connector - mounted on the
sensor (connected status)
the lowest protection is applicable
2)
Up to 45 °C (113 °F) ambient temperature, see derating of the manufacturer.
Plug connector Harting HAN 8D for continuously measuring sensors 5
Supplement
30376-EN-080307
6 Plug connector Harting HAN 8D for continuously measuring sensors
Supplement
30376-EN-080307
Plug connector Harting HAN 8D for continuously measuring sensors 7
Supplement
30376-EN-080307
VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info@de.vega.com
www.vega.com
Printing date:
ISO 9001
All statements concerning scope of delivery, application,
practical use and operating conditions of the sensors and
processing systems correspond to the information avail-
able at the time of printing.
© VEGA Grieshaber KG, Schiltach/Germany 2008
Subject to change without prior notice 30376-EN-080307
Loading...