VEGA BAR14 User Manual

Operating Instruction
VEGABAR 14
s
Document ID:
22441
Process pressur
e

Contents

Contents
1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Target group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Symbolism used . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 For your safety
2.1 Authorised personnel . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . .
2.4 General safety instructions . . . . . . . . . . . . . . . . . . . .
2.5 Safety label on the instrument . . . . . . . . . . . . . . . . . .
2.6 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.7 Measuring range - permissible process pressure . . . .
2.8 Fulllment of NAMUR recommendations . . . . . . . . . .
2.9 Safety instructions for Ex areas . . . . . . . . . . . . . . . . .
2.10 Environmental instructions. . . . . . . . . . . . . . . . . . . . .
3 Product description
3.1 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Principle of operation . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4 Packaging, transport and storage . . . . . . . . . . . . . . .
4 Mounting
4.1 General instructions . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Instructions for installation . . . . . . . . . . . . . . . . . . . . .
4.3 Mounting steps. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Connecting to power supply
5.1 Preparing the connection . . . . . . . . . . . . . . . . . . . . .
5.2 Connection procedure. . . . . . . . . . . . . . . . . . . . . . . .
5.3 Wiring plan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Switch-on phase. . . . . . . . . . . . . . . . . . . . . . . . . . . .
document
4 4 4
5 5 5 5 6 6 6 6 6 6
7 7 8 8
9 9 9
11 12 15 16
6 Set up
6.1 Setup steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Maintenance and fault rectication
7.1 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Remove interferences . . . . . . . . . . . . . . . . . . . . . . . .
7.3 Instrument repair . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Dismounting
8.1 Dismounting steps . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Supplement
9.1 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 VEGABAR 14
17
18 18 19
20 20
21
22441-EN-111006
Contents
9.2 Dimensions .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
26
Supplementary documentation
Information:
Suppleme
ntary documents appropriate to the ordered version come
with the delivery. You can nd them listed in chapter "Product
description".
Instructions manuals for accessories and replacement parts
Tip:
re reliable setup and operation of your VEGABAR 14, we oer
To ensu
accessories and replacement parts. The corresponding documenta­tions are:
l 32036 - Welded socket and seals
Editing status: 2011-09-23
22441-EN-111006
VEGABAR 14 3

1 About this document

1 About this document

1.1 Function

is operating instructions manual provides all the information you
Th need for mounting, connection and setup as well as important instructions for maintenance and fault rectication. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained qualied personnel. The contents of this manual should be made available to these personnel and put into practice by them.
1.3 Symbolism used
Information, tip, note
This
symbol indicates helpful additional information.
Caution: If this result. Warning: If this warning is ignored, injury to persons and/or serious damage to the instrument can result. Danger: If this warning is ignored, serious injury to persons and/or destruction of the instrument can result.
applications
Ex
Th
symbol indicates special instructions for Ex applications.
is
l List
The dot set in front indicates a list with no implied sequence.
warning is ignored, faults or malfunctions can
à Action
This a
rrow indicates a single action.
1 Sequence
Numbers set in front indicate successive steps in a procedure.
22441-EN-111006
4 VEGABAR 14

2 For your safety

2 For your safety
2.1 Auth
All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.
During work on and with the device the required personal protective equipment must always be worn.
orised personnel

2.2 Appropriate use

VEGABAR 14 is a pressure transmitter for measurement of gauge pressure, absolute pressure and vacuum.
You can nd detailed information on the application range in chapter
"Product description".
Operational reliability is ensured only if the instrument is properly used according to the specications in the operating instructions manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device beyond that described in the operating instructions manual may be carried out only by personnel authorised by the manufacturer. Arbitrary conversions or modications are explicitly forbidden.

2.3 Warning about misuse

Inappropriate or incorrect use of the instrument can give rise to application-specic hazards, e.g. vessel overll or damage to system components through incorrect mounting or adjustment.

2.4 General safety instructions

This is a high-tech instrument requiring the strict observance of standard regulations and guidelines. The user must take note of the safety instructions in this operating instructions manual, the country­specic installation standards as well as all prevailing safety regulations and accident prevention rules.
The instrument must only be operated in a technically awless and reliable condition. The operator is responsible for trouble-free operation of the instrument.
During the entire duration of use, the user is obliged to determine the compliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new regulations.
22441-EN-111006
VEGABAR 14 5
2 For your safety
2.5 Safety label
The safety approval markings and safety tips on the device must be observed.
on the instrument

2.6 CE conformity

This device fullls the legal requirements of the applicable EC guidelines. By attaching the CE mark, VEGA provides a conrmation of successful testing. You can nd the CE conformity declaration in the download area of
2.7 Measuring range - permi
www.vega.com.
ssible process pres-
sure
Due to the application, a measuring cell with a measuring range higher than the permissible pressure range of the process tting may have been integrated. The permissible process pressure is stated with
"Process pressure" on the type label, see chapter 3.1 "Conguration". For safety reasons, this range must not be exceeded.
2.8 Fulllment of NAMUR recommendations
With respect to interference resistance and emitted interference, the NAMUR recommendation NE 21 is fullled.

2.9 Safety instructions for Ex areas

Please note the Ex-specic safety information for installation and operation in Ex areas. These safety instructions are part of the operating instructions manual and come with the Ex-approved instruments.

2.10 Environmental instructions

Protection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental protection.
The environment management system is certied according to DIN EN ISO 14001.
Please help us full this obligation by observing the environmental
instructions in this manual:
l Chapter "Packaging, transport and storage" l Chapter "Disposal"
6 VEGABAR 14
22441-EN-111006

3 Product description

3
1
2

3.1 Structure

3 Product description
pe of delivery
Sco
Structure
Type label
e scope of delivery encompasses:
Th
l VEGABAR 14 process pressure transmitter l depending on the version, with plug connector, direct cable outlet
or plug connector with connection cable
l Documentation
- this operating instructions manual
- Ex-specic "Safety instructions" (with Ex versions)
- if necessary, further certicates
Fig. 1: VEGABAR 14 with
1 Process tting 2 Housing 3 Cable outlet
with electronics
cable
outlet
The type label contains the most important data for identication and use of the instrument:
l Article number l Serial number l Technical data l Article numbers, documentation
With the serial number, you can access the delivery data of the instrument via
www.vega.com, "VEGA T
ools" and "serial number
search". In addition to the type label outside, you can also nd the
serial number on the inside of the instrument.

3.2 Principle of operation

Application area
22441-EN-111006
VEGABAR 14 7
VEGABAR 14 is a pressure transmitter for measurement of gauge
pressure, absolute pressure or vacuum. Measured products are gases, vapours and liquids.
3 Product description
Func
tional principle
Voltage supply
Packaging
Transport
Transport inspection
®
The sensor element is the CERTEC
measuring cell with rugged ceramic diaphragm. The process pressure causes a capacitance change in the measuring cell via the ceramic diaphragm. This change is converted into an appropriate output signal and outputted as measured value.
Two-wire electronics 4 … 20 mA for power supply and measured value transmission over the same cable.

3.3 Operation

The instrument oers no adjustment options.

3.4 Packaging, transport and storage

The device was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
The packaging of standard instruments consists of environment­friendly, recyclable cardboard. For special versions, PE foam or PE foil is also used. Dispose of the packaging material via specialised recycling companies.
Transport must be carried out under consideration of the notes on the transport packaging. Nonobservance of these instructions can cause damage to the device.
The delivery must be checked for completeness and possible transit damage immediately at receipt. Ascertained transit damage or concealed defects must be appropriately dealt with.
Storage
Up to the time of installation, the packages must be left closed and stored according to the orientation and storage markings on the outside.
Unless otherwise indicated, the packages must be stored only under the following conditions:
l Not in the open l Dry and dust free l Not exposed to corrosive media l Protected against solar radiation l Avoiding mechanical shock and vibration
Storage and transport temp
erature
l Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
l Relative humidity 20 85 %
8 VEGABAR 14
22441-EN-111006

4 Mounting

4 Mounting
bility for the pro-
Suita cess condition
Mounting position
Welding the socket
Sealing/Screw
s
ing
4.1 General ins
Make sure that all parts of the instrument exposed to the process, in particular the sensor element, process seal and process tting, are suitable for the existing process conditions. These include above all the process pressure, process temperature as well as the chemical properties of the medium.
You can nd the specications in chapter "Technical data" or on the type label.
tructions

4.2 Instructions for installation

VEGABAR 14 functions in any installation position. It is mounted according to the same directives as a manometer (DIN EN 839-2).
Information:
We recommen siphons from our line of accessories.
d using lock ttings, measuring instrument holders and

4.3 Mounting steps

For mounting VEGABAR 14, a welded socket is required. You can nd these components in the supplementary instructions manual "Welded
socket and seals".
in
Use the attached seal:
l Process tting GV, GB and GP
- or -
Seal the thread with teon, hemp or a similar resistant seal material:
l Process tting GN
à Screw VEGABAR 14 into the welded socket. Tighten the hexagon
screw on the process tting. Wrench size, see chapter "Dimen- sions", torque see chapter "Technical data".