UNVENTED (VENT-FREE)
CAST IRON GAS STOVE HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
Amity™ Models:
SCIVFB Azure Blue SCIVFR Burgundy Red
SCIVFGA Hunter Green SCIVFCA Charcoal
PSCIVFG Porcelain Enamel Hunter Green
PSCIVFR Porcelain Enamel Red
PSCIVFS Porcelain Enamel Sand
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable vapors
or liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier fr om a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed b y a qualified installer, service agency, or the gas supplier.
This stove may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or
local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer (i.e., Installation of this product is permitted after the
manufactured [mobile] home is sited).
Save this manual for future reference.
Sheraton™ Models:
NSCIVFC Charcoal
NSCIVFT Topaz
WARNING: Improper installa-
tion, adjustment, alteration, ser-
vice, or maintenance can cause
injury or property damage. Re-
fer to this manual for correct
installation and operational pro-
cedures. For assistance or ad-
ditional information consult a
qualified installer, service
agency or the gas supplier.
WARNING: The SCIVFB,
SCIVFGA, SCIVFCA, SCIVFR,
NSCIVFC, NSCIVFT, and
PSCIVFG, PSCIVFR, and
PSCIVFS Gas Stove Heaters
are to be used only with
SVYD18P/N/NR/PR vent-free
gas log heaters. Do not burn
wood or other materials in
these gas stove heaters.

SAFETY INFORMATION
WARNINGS
WARNING: Any change to this stove or its con-
trols can be dangerous.
1. This stove shall not be installed in a bedroom or bathroom.
2. Never install the stove
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable objects are less than 36 inches from the front, top or sides of
the stove
• in high traffic areas
• in windy or drafty areas
3. Do not use this stove as a wood-burning fireplace. Use only
SVYD18P/N/PR/NR Vent-Free Gas Log Heaters.
4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting.
5. Do not allow fans to blow directly into the stove. Avoid any
drafts that alter burner flame patterns. Altered burner patterns
can cause sooting.
6. Do not use a blower insert or heat exchanger insert with this
stove.
7. V ent-free gas log heaters installed in these stov es require fresh
air ventilation to run properly. See Air for Combustion and
Ventilation in the SVYD18P/N/PR/NR Owner’s Operation and
Installation manual.
8. Do not run stove
• where flammable liquids or vapors are used or stored
• under dusty conditions
9. Do not use this stove to cook food or burn paper or other
objects.
10. Never place any objects in the stove or on logs.
11. Stove sides, front and top become very hot when running stove.
Keep children, adults and pets away from hot surfaces to avoid
burns or clothing ignition. Stove will remain hot for a time
after shut-down. Allow surfaces to cool before touching.
12. Carefully supervise young children when they are in the room
with stove.
13. Turn stove off and let cool before servicing. Only a qualified
service person should service and repair stove.
14. Operating stove above elevations of 4,500 feet could cause
pilot outage.
IMPORTANT: Refer to the Owner’s Operation and Installation Manual included with
your SVYD18P/N/PR/NR Vent-Free Gas Log Heater for all assemb ly and installation
instructions and contents listing.
Amity™ and Sheraton™ are a registered trademark of NU-TEC Inc, East Greenwich, RI
2701 Industrial Drive
P.O. Box 90004
Bowling Green, KY 42102-9004
104680 01
NOT A UPC
104680-01
Rev . A
04/98