Vanguard Aristocrat V42E, Aristocrat V42EC2 Installation Instructions Manual

®
INSTALLATION INSTRUCTIONS
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers.
23 5/16''
1
13
/8''
ROUND TOP TERMINATION
ARISTOCRAT™
42" WOODBURNING FIREPLACES
Model V42E Non-Circulating (Smooth Face)
Model V42EC2 Circulating (Louvered)
22"
17 1/2"
3
37
/8"
13
41
/16"
STORM COLLAR
43
1
13/16''
/4"
38
12
7
/16"
3
1
/8"
OPENING FOR
OUTSIDE
AIR KIT
3
/4''
1
8
/2"
42''
9
/16"
44
GAS LINE CONDUIT SLEEVE (BOTH SIDES)
22"
(LEFT SIDE ONLY)
1
/4"
12
1
22
/16''
3
7
/8"
0" TO TOP OF SPACER
3/4" AIR SPACE BACK AND SIDES
OUTSIDE AIR
0" TO BOTTOM
12" EACH
SIDE
FLASHING
FIRESTOP
2" AIR SPACE TO COMBUSTIBLE MATERIALS
HEARTH EXTENSION 66" X 20"
COMBUSTIBLE WALL BOARD
NO COMBUSTIBLE MATERIAL ON FACE
NOT LESS
THAN 24" TO
PERPENDICULAR
SIDEWALL
f i r e - p a r t s . c o m
®
DESA INTERNATIONAL, 2701 INDUSTRIAL DRIVE P.O. BOX 90004 BOWLING GREEN, KY 42102-9004
Model Serial No. Date Purchased
55510 Rev. B 08/99
FOR YOUR SAFETY
• Do not store or use gasoline or any other flam­mable vapors or liquids in the vicinity of this or any other appliance.
• Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
• Do not place clothing or other flammable materials on or near the appliance.
• NEVER leave children unattended when a fire is burning in the fireplace.
WARNING: IMPROPER INSTALLATION, ADJUST­MENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY, PROPERTY DAMAGE, OR LOSS OF LIFE. REFER TO THIS MANUAL. FOR ASSIS­TANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER OR LOCAL DISTRIBUTOR.
WARNING: THIS FIREPLACE IS INTENDED FOR USE WITH WOOD, OR IF A VENT-FREE OR DECORATIVE GAS APPLIANCE IS INSTALLED, BURN PROPANE/ LP OR NATURAL GAS ONLY.
CHECK LOCAL CODES PRIOR TO INSTALLATION
INSTALLATION INSTRUCTIONS INTRODUCTION
Before beginning the installation of your fireplace, read these
f i r e - p a r t s . c o m
instructions through completely. These Vanguard components and fireplaces are safe when installed
according to this Installation Manual. Unless you use Vanguard components, which have been designed and tested for the fireplace systems, you may cause a fire hazard.
The DESA International warranty will be voided by, and DESA International disclaims any responsibility for the following actions.
a) Modification of the fireplace, components, doors, air inlet sys-
tem and the damper control.
b) Use of any component part not manufactured or approved by
DESA International in writing, in combination with DESA In­ternational fireplace systems.
Refer to your Home owners guide for warranty information.
This wood burning fireplace complies with UL 127 as a FACTORY BUILT FIREPLACE and is listed and tested by
Underwriters Laboratory Inc.
This model is not for use in mobile homes.
WARNING: DO NOT USE A FIREPLACE INSERT IN THIS FIREPLACE UNLESS THE MANUFACTURER’S INSTRUCTIONS WITH THE INSERT SPECIFICALLY STATE THIS FIREPLACE HAS BEEN TESTED FOR USE WITH THE INSERT.
PROPER INSTALLATION is the most important step in ensuring safe and continuous operation of this fireplace. Consult the local building codes as to the particular requirements concerned with the installation of all factory-built fireplaces. Although grounding may not be required by code the manufacturer recommends it.
This fireplace is not intended to be used as a substi­tute for a furnace to heat an entire home. Use for supplementary heating only.
MINIMUM CLEARANCES TO COMBUSTIBLES
Framing and enclosures may safely make direct contact with the spacers on the top of the fireplace. The fireplace may sit directly on combustible flooring. The fireplace opening must not be less than 24 inches from combustible materials and the chimney must be abso­lutely maintained. A 16 mended as a minimum size. A 3/4 inch air space required around back and sides of fireplace.
Keep all combustible furnishings a considerable distance from the fireplace.
WARNING: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liq­uids to start or “freshen up” a fire in this fireplace. Keep all such liquids well away from the fireplace.
WARNING: DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS.
1
/2 inch inside chase dimension is recom-
HEIGHT
The minimum height of the chimney, measured from the base of the fireplace to the flue gas outlet, is 16 feet for a straight chimney with one elbow set. For systems with 2 elbow sets, the minimum height is 30 feet. The maximum height of any system is 40 feet. This measurement includes the fireplace, chimney sections and the effec­tive height of the termination assembly.
GENERAL
Read the Warranty and Operating guidelines supplied with this fireplace. Following these simple guidelines will ensure years of trouble free and safe usage of your fireplace. If the Warranty and Operating instructions are not in your fireplace, write to the address listed on the front cover.
2
55510
INSTALLING THE FIREPLACE
STEP 1: Frame the opening for the fireplace using the dimensions shown in Figures 1 or 2.
STEP 2: Set the fireplace directly in front of this opening and slide the unit back until the mounting flanges touch the side framing.
STEP 3: Check the level of the fireplace and shim with sheet metal if necessary.
STEP 4: When the fireplace is installed upon a combustible floor a galvanized sheet ember protector (provided) must be installed be­tween the fireplace and the hearth extension as illustrated in Figures 15 and 16, page 7.
STEP 5: Secure the fireplace to the framing through the nailingflanges located on the sides on the fireplace with nails or sheet rock screws.
NOTE: The 3/4" clearance is not required at the nailing flange (see Figure 12, page 6).
3
/16"
11
1
/2"
43
ASSEMBLING AND INSTALLING YOUR DOUBLEWALL CHIMNEY SYSTEM
Each double wall chimney section consists of an outer pipe, flue pipe and one wire spacer. The pipe sections are not unitized and must be assembled independently as the chimney is installed. When starting the chimney directly on the fireplace, the flue pipe section must be installed first, with lanced side up. The outer pipe section can then be installed over the flue pipe section with the hemmed end up (see Figure 3).
Press down on each pipe section until the lances securely engage the hem on the fireplace starter. The wire spacer will assure the proper spacing between the inner and outer pipe sections.
LINEAL GAIN: THE ACTUAL MEASURABLE LENGTH OF A PART AFTER TWO OR MORE
PARTS ARE CONNECTED.
3
12
/8 GALVANIZED
OUTER PIPE
HEMMED
END
8 IN.
STAINLESS
INNER PIPE
Figure 3
PART NO. DESCRIPTION GAIN (IN) V42 E/EC FIREPLACE 42
V12-8DM PIPE SECTION 10 5/ V18-8DM PIPE SECTION 16 5/ V24-8DM PIPE SECTION 23 5/ V36-8DM PIPE SECTION 34 5/ V48-8DM PIPE SECTION 46 5/
VRTL-8DM ROUND 6
VRTTL-8DM TERMINATION
VETO-8DM CHASE 1 to 2
VETLO-8DM TERMINATION
LINEAL GAIN
8
8
8
8
8
45 1/4"
Figure 1
FRAMING DIMENSIONS
f i r e - p a r t s . c o m
23 5/8"
Continue to assemble chimney sections as outlined above, making sure both inner and outer pipe sections are locked together. When installing double wall "snap lock" chimney together, it is important to assure the joint between the chimney sections are locked. Check
15
3
/8"
by pulling chimney upward after locking. The chimney will not come apart if properly locked. It is not necessary to add screws to
46 5/8"
33"
12
5
/8"
keep the chimney together.
WARNING: THE OPENING IN THE COLLAR AROUND THE TOP OF THE FIREPLACE MUST NOT BE OB­STRUCTED. NEVER USE BLOWN INSULATION TO FILL THE CHIMNEY ENCLOSURE (SEE FIGURE 4).
66"
Figure 2
FRAMING DIMENSIONS