WSP150 Surge Protector
WSP150 - powerful technology in a compact size.
Features/Benefits
Superior three-stage, transient
▪
surge protection
Tolerates up to 10 kA surge
▪
currents
Noise filtering against HF and
▪
RF interference
Robust structure, IP66 housing
▪
Both dierential and common
▪
mode protection on each
channel
2 power and 2 data channels
▪
Can be used with all Vaisala
▪
wind and weather instruments
Applications: mast installations
▪
of weather measurement
networks, MET stations in wind
parks
WSP150
The Vaisala Surge Protector WSP150
is a compact transient overvoltage
suppressor designed for outdoor use.
It can be used with all Vaisala wind
and weather instruments.
Superior protection
A lightning strike nearby may
induce a high voltage surge, which
the integral transient suppressor
of the instrument may not tolerate.
Therefore, additional protection is
needed, especially where frequent
and severe thunderstorms are
common and where long cables of
more than 30 m are used.
www.vaisala.com
The WSP150 offers three-stage
protection against surge currents up
to 10 kA entering through the power
and signal cables.
Powerful technology
The WSP150 has four channels, two
of which are dedicated to power lines
and two for data lines. Each channel
uses a three-stage protection scheme
as follows: rst there are discharge
tubes, then voltage dependent
resistors (VDR), and nally transient
zener diodes. Between each stage,
there are either series inductors or
resistors.
Both differential and common mode
protection is provided for each
channel: across the wire pairs,
against the operating voltage ground,
and against the earth.
The WSP150 also includes noise
ltering against HF and RF
interference.
Applications
Vaisala recommends using the
WSP150 when wind and weather
instruments are installed on top of
high buildings or masts and in open
grounds, that is, anywhere with an
elevated risk of lightning.
Also use the WSP150 if your cable
length exceeds 30 m or you have
unshielded, open-wire lines.
69
58
94
130
120
Line cable Device cable,
max. 3 meters
16 mm
2
copper wire
Technical data
Maximum characteristics
Dimensions
Input voltage
(across channel line pair and from line to GND, terminals #3)
power channels max. ±43 V
data channels max. ±13 V
Input common mode voltage
any line to earth max. ±72 V
Throughput current
power lines max. 1.5 A
data lines max. 0.16 A
Throughput resistance (per line)
power lines 0.3 ohms
data lines 15 ohms
Turn-on voltage
power channels max. ±60 V
data channels max. ±16 V
Surge current
to earth max. 10 kA
differential max. 5 kA
EMC surge tolerance EN 61000-4-5, (4 kV, 2kA)
IEEE C62.45 (6 kV, 3 kA)
General
Operating and storage temperature -52 ... +70 °C
(-60 ... +158 °F)
Installation and maintenance work temperature -40 ... +70 °C
(-40 ... +158 °F)
Environmental protection class IP66 (NEMA 4X)
Dimensions
housing (w x h x d) 130 x 94 x 58 mm
with cable glands and mounting assembly 130 x 120 x 69 mm
cables ø 4 ... 8 mm
wires ø 0.4 ... 1.7 mm
(AWG 26 ... 14)
Housing material polycarbonate, stainless steel
Weight 0.65 kg
WSP150 CAN BE USED WITH, FOR EXAMPLE, THE FOLLOWING
VAISALA INSTRUMENTS:
WXT520
WMT52
WM30
WS425
WA15 + WAC151/WAC155/WAT12
WA25 + WAC151/WAC155/WAT12
For more information, visit
www.vaisala.com or contact
us at sales@vaisala.com
Ref. B210654EN-B ©Vaisala 2009
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.