Vaisala CMP6 Technical data

CMP6 Solar Radiation Sensor
www.vaisala.com
Features/Benefits
First Class standard (ISO
9060/WMO)
Reliable all weather
performance
For atmospheric research and
meteorology
The CMP6 pyranometer is intended for routine global solar radiation measurement research on a plane/ level surface.
Fully compliant with ISO-9060 specication for a First Class pyranometer, the CMP6 features a sixty-four thermocouple junction (series connected) sensing element.
The sensing element is coated with a highly stable carbon based non organic coating, which delivers excellent spectral absorption and long-term stability characteristics.
CMP6 has improved performance due to the increased thermal mass and the double glass dome construction. It is ideal for good quality measurements in meteorological networks.
Technical data
General
Spectral range 285 to 2800 nm Sensitivity 5 to 20 µV/W/m² Response time 18 s Zero offset A ± 15 W/m² Zero offset B ± 4 W/m² Directional error (up to 80 ° with 1000 W/m² beam) < 20 W/m² Temperature dependence of sensitivity (-10 ºC to +40 ºC) ± 4 % Operating temperature range -40 °C to +80 °C Maximum solar irradiance 2000 W/m² Field of view 180 °
The integral bubble level is raised to the top of the housing and can be viewed without removing the redesigned snap-on sun shield, which also covers the connector. The connector with gold-plated contacts allows for easy exchange and re­calibration.
The screw-in drying cartridge is easy to remove and the replacement desiccant is supplied in convenient rell packets.
For more information, visit www.vaisala.com or contact us at sales@vaisala.com
Ref. 2010-17-11 ©Vaisala 2010
This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners. All rights reserved. Any logos and/or product names are trademarks of Vaisala or its individual partners. The reproduction, transfer, distribution or storage of information contained in this brochure in any form without the prior written consent of Vaisala is strictly prohibited. All specifications — technical included — are subject to change without notice.