Vaillant VRT 360f Operation Manual

For the owner and heating engineer
VRT 360f
Operating and Installation Manual
VRT 360f
Room temperature thermostat
GB
2
Operating and installation manual VRT 360f
Inhaltsverzeichnis
Notes on the documentation . . . . . . 4
Storage of the documents .................... 4
Symbols used ........................................... 4
Safety . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating manual . . . . . . . . . . . . . . . . 6
1
Overview of the equipment . . . . . 6
2 Overview of the display . . . . . . . 7
3 Description of the appliance . . . 8
4 Operation . . . . . . . . . . . . . . . . . . . 8
4.1 Setting the operating modes ...... 9
4.2 Setting the current day and
time ................................................... 12
4.3 Setting timer programmes .......... 13
4.4 Setting the room temperature ... 16
4.5 Setting the hot water
temperature .................................... 18
4.6 Activating special functions ........ 19
4.7 Info level ........................................... 22
4.8 Changing the battery .................... 23
5 Manufacturer’s warranty and
liability . . . . . . . . . . . . . . . . . . . . 25
6 Recycling and disposal . . . . . . . . 25
3Operating and installation manual VRT 360f
Contents
GB
Installation instructions . . . . . . . . . . 27
7
Notes on the installation and
operation . . . . . . . . . . . . . . . . . . . 27
7.1 CE label ............................................. 27
7.2 Intended use .................................... 28
8 Safety instructions and regulati-
ons . . . . . . . . . . . . . . . . . . . . . . . . 29
8.1 Safety instructions ........................ 29
8.2 Regulations ...................................... 30
9 Installation . . . . . . . . . . . . . . . . . 31
9.1 Place of installation ....................... 31
9.2 Fitting the receiver ........................ 31
9.3 Mounting the room temperature
thermostat ....................................... 33
10 Electrical installation . . . . . . . . . 35
10.1 Connecting the receiver ............... 35
11 Start-up . . . . . . . . . . . . . . . . . . . . 36
11.1 Installer level ................................... 37
11.2 Service/diagnostics level .............. 41
11.3 Handing over the appliance to
the owner ......................................... 43
12 Troubleshooting . . . . . . . . . . . . . 44
13 Technical data . . . . . . . . . . . . . . . 45
14 Vaillant Service . . . . . . . . . . . . . 46
4 Operating and installation manual VRT 360f
Notes on the documentation
The following information is intended to help you throughout the entire documentation. Other documents apply in combination with this installation and operation manual.
We accept no liability for any damage caused by failure to observe these instructions.
Storage of the documents
Please pass on this operating and installation manual to the owner of the system in order for him/her to store it so that it is available whenever it is required.
Symbols used
Please observe the safety instructions in this manual for the installation of the appliance.
Danger!
Immediate risk of serious injury or death
Caution!
Potentially dangerous situation for the product and environment.
Notes on the documentation
5GBOperating and installation manual VRT 360f
Note!
Useful information and instructions.
• Symbol for a necessary task
Safety
The room temperature thermostat must be installed by a suitably qualified heating engineer, who is responsible for adhering to the existing standards and regulations.
We accept no liability for any damage caused by failure to observe these instructions.
Notes on the documentation, safety
6 Operating manual VRT 360f
Operating manual
1
Overview of the equipment
1
2
Abb. 1.1 Overview of equipment
Key
1 Display 2 Dial (turn and click) I Info button F Special functions button P Programming key/installer level
1 Overview of the device
7GBOperating manual VRT 360f
2 Overview of the display
1
2
3
4
5
6
7
8
9
11
10
Fig. 2.1 Overview of the display
Key
1 Installer level and Service/Diagnosis level (Chapter 11.1) 2 Info level (see 4.7) 3 Hot water symbol 4 Circulation pump symbol 5 Heating circuit symbol 6 Time/temperature display 7 Days of the week 8 Actual temperature 9 Operating modes (see 4.1) 10 Special functions (see 4.6) 11 Setting timer programmes (see 4.3)
Overview of the display 2
8 Operating manual VRT 360f
3 Description of the
appliance
The VRT 360f is a programmable room temperature thermostat with weekly programme for heating, hot water and circulation pump for connection to Vaillant heating equipment with eBus. The connection between the room temperature thermostat and the heating unit is by radio link. The VRT 360f enables you to specify the room temperature using heating programs. In addition, you can select special functions such as the party function, and control the timed
operation of a boiler and a circulation pump.
4 Operation
The operating principle is based on the three buttons and an dial (Vaillant "turn and click“ operating concept). The display normally shows the current operating mode (e.g.
), or, if activated, the special function and the current room temperature, the day of the week, the time and the symbol for heating, hot water and/or the circulation pump, depending on which is requested.
3 Device description, 4 Operation
9GBOperating manual VRT 360f
4.1 Setting the operating modes
T
able 4.1 provides you with an overview of the operating modes you can select. The selected operating mode affects the timer programmes both for heating and for hot water and the circulation pump.
• When the room temperature
thermostat is in normal display mode. press the dial once – the symbol for the selected mode flashes in the display.
• Turn the dial until the desired
operating mode appears on the
display. The display switches back to normal mode after five seconds.
Operation 4
10 Operating manual VRT 360f
Symbol Meaning
Heating Hot water Automatic:
The operation of the heating circuit changes between the operation modes Heating and Energy Saving
. The heating circuit symbol is displayed if a heating
requirement is detected.
The operation of the hot water storage cylinder/circulation pump changes between heating/ON and OFF depending upon the time programme set on the room temperature thermostat. The hot water symbol and the circulation pump symbol are displayed if the time window is active.
Heating:
The heating circuit is operated according to the room temperature, regardless of the programme set on the room temperature thermostat. The heating circuit symbol is displayed if a heating requirement is detected.
Energy Saving:
The heating circuit is operated according to the energy saving temperature "ECO“, regardless of the programme set on the room temperature thermostat. The heating circuit symbol is displayed if a heating requirement is detected.
Table 4.1 Operating modes
4 Operation
11GBOperating manual VRT 360f
Symbol Meaning
Heating Hot water Off:
The heating circuit is off, provided that the frost protection function (if the room temperature is below 5°C) is not activated. If the frost protection function is activated, the heating circuit symbol is displayed.
The boiler is not heated up, regardless of the set timer programme. The circulation pump is switched off. The hot water and circulation pump symbols are not displayed.
Table 4.1 Operating modes (contd.)
Operation 4
12 Operating manual VRT 360f
4.2 Setting the current day and
time
To set the current time and day of the week with the display in normal mode, you must perform the following steps:
• Press the dial until a day of the week
starts flashing.
• Turn the dial until you see the current
day of the week.
MO = Monday
TU = Tuesday
WE = Wednesday
TH = Thursday
FR = Friday
SA = Saturday
SU = Sunday
• Press the dial. The hours start flashing.
• Turn the dial until you see the current hour.
• Press the dial. The minutes start flashing.
• Turn the dial until you see the current minute.
The display switches back to normal mode after five seconds. If the calendar is activated on the installer level (see 11.1), you can set the day, month and year in the same way after you set the time. This allows automatic switching from winter to summer time.
4 Operation
13GBOperating manual VRT 360f
4.3 Setting timer programmes
T
he room temperature thermostat is
equipped with a basic program (see table
4.2).
Time window
Current day / Block of days
Start time
End time
H1 M0 - FR 6:00 22:00 H2 — H3 — H1 SA 7:30 23:30 H2 — H3 — H1 SU 7:30 22:00 H2 — H3
Table 4.2 Default heating, hot water and
circulation pump programmes
You can adapt the default programmes to suit your needs. There are six steps to setting the times you want.
1. Press the programming button P
2. Select the timer programme (heating, hot water or circulation pump)
3. Select the time window
4. Select the current day or week block
5. Set the start time.
6. Set the end time.
Operation 4
14 Operating manual VRT 360f
You can define three time windows for each day. When you press the P button the display returns to basic mode. The table below illustrates the individual steps again, using the example of the hot water timer programme. If you want to change the timer programme for heating or the circulation pump, after pressing the programming button P, select the corresponding symbol (heating circuit or circulation pump) and continue as shown in the example.
Display Required steps
Press the programming button P. The cursor (black triangle) marks the value which can be changed ( ), which also flashes. Turn the dial until the tap symbol appears.
Press the dial. The cursor marks the adjustable value (H1), which also flashes. Select the desired time window by turning the dial. Settings: H1, H2, H3
4 Operation
15GBOperating manual VRT 360f
Display Required steps
Press the dial. The cursor marks the week block display, which also flashes. Select a block programme or a single day of the week by turning the dial. Settings: MO - SU MO - FR SA - SU MO = Monday TU = Tuesday WE = Wednesday TH = Thursday FR = Friday SA = Saturday SU = Sunday
Display Required steps
Press the dial. The cursor marks the start time and the hour display flashes. Select the start time by turning the dial. Press the dial again to set the minutes.
Press the dial. The cursor marks the end time and the hour display flashes. Select the end time by turning the dial. Press the dial again to set the minutes.
Table 4.3 Setting time windows