Vaillant VRT 340f Operation Manual

Page 1
For the owner and heating engineer
VRT 340f
Operating and Installation Manual
VRT 340f
Room temperature thermostat
GB
Page 2
2
Operating and installation manual VRT 340f
Contents
Notes on the documentation . . . . . . 4
Storage of the documents .................... 4
Symbols used ........................................... 4
Safety . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating manual . . . . . . . . . . . . . . . . 6
1 Overview of the equipment . . . . . 6
2 Overview of the display . . . . . . . 7
3 Description of the appliance . . . 8
4 Operation . . . . . . . . . . . . . . . . . . . 8
4.1 Setting the operating modes ...... 9
4.2 Setting the current day and
time ................................................... 12
4.3 Setting the heating times ............ 13
4.4 Setting the room temperature ... 15
4.5 Activating special functions ........ 16
4.6 Info level ........................................... 18
4.7 Changing the battery .................... 19
5 Manufacturer’s warranty and
liability . . . . . . . . . . . . . . . . . . . . 20
6 Recycling and disposal . . . . . . . . 21
Page 3
3Operating and installation manual VRT 340f
Contents
GB
Installation instructions . . . . . . . . . . 22
7
Notes on the installation and
operation . . . . . . . . . . . . . . . . . . . 22
7.1 CE label ............................................. 22
7.2 Intended use .................................... 23
8 Safety instructions and
regulations . . . . . . . . . . . . . . . . . 24
8.1 Safety instructions ........................ 24
8.2 Regulations ...................................... 25
9 Installation . . . . . . . . . . . . . . . . . 25
9.1 Place of installation ....................... 25
9.2 Fitting the receiver ........................ 26
9.3 Mounting the room temperature
thermostat ....................................... 27
10 Electrical installation . . . . . . . . . 28
10.1 Connecting the receiver ............... 29
11 Start-up . . . . . . . . . . . . . . . . . . . . 29
11.1 Installer level ................................... 31
11.2 Service/diagnostics level .............. 34
11.3 Handing over the appliance
to the owner .................................... 36
12 Troubleshooting . . . . . . . . . . . . . 37
13 Technical data . . . . . . . . . . . . . . . 38
14 Vaillant Service . . . . . . . . . . . . . 39
Page 4
4 Operating and installation manual VRT 340f
Notes on the documentation
The following information is intended to help you throughout the entire documentation. Other documents apply in combination with this installation and operation manual.
We accept no liability for any damage caused by failure to observe these instructions.
Storage of the documents
Please pass on this operating and installation manual to the owner of the system in order for him/her to store it so
that it is available whenever it is required.
Symbols used
Please observe the safety instructions in this manual for the installation of the appliance.
Danger!
Immediate risk of serious injury or death
Caution!
Potentially dangerous situation for the product and environment.
Notes on the documentation
Page 5
5GBOperating and installation manual VRT 340f
Note!
Useful information and instructions.
• Symbol for a necessary task
Safety
The room temperature thermostat must be installed by a suitably qualified heating engineer, who is responsible for adhering to the existing standards and regulations.
We accept no liability for any damage caused by failure to observe these instructions.
Notes on the documentation, safety
Page 6
6 Operating manual VRT 340f
Operating manual
1 Overview of the equipment
1
2
Abb. 1.1 Overview of equipment
Key
1 Display 2 Dial (turn and click) I Info button F Special functions button P Programming key/installer level
1 Overview of the device
Page 7
7GBOperating manual VRT 340f
2 Overview of the display
4
1
2
3
5
6
7
8
9
10
Fig. 2.1 Overview of the display
Key
1 Installer level and service/diagnostics level 2 Info level 3 Timer programming 4 Time/temperature display 5 Days of the week 6 Actual temperature 7 Operating modes 8 Special functions 9 Heating circuit symbol 10 Hot water symbol
Overview of the display 2
Page 8
8 Operating manual VRT 340f
3 Description of the
appliance
The VRT 340f is a room temperature thermostat with a weekly heating program for connecting to modulating Vaillant boilers. The connection between the room temperature thermostat and the heating unit is by radio. The VRT 340f enables you to specify the room temperature using heating programs. In addition, you can set the special functions, such as the party function, as well as the time control of a hot water storage.
4 Operation
The operating principle is based on the three buttons and an dial (Vaillant "turn and click“ operating concept). The display normally shows the current operating mode (e.g.
and ), or, if activated, the respective special function and the current room temperature, the day of the week, the time and the heating circuit symbol, if heating is required.
3 Device description, 4 Operation
Page 9
9GBOperating manual VRT 340f
4.1 Setting the operating modes
T
able 4.1 provides you with an overview
of the operating modes you can select.
• When the room temperature thermostat is in normal display mode. press the dial once – the symbol for the selected mode flashes in the display.
• Turn the dial until the desired operating mode appears on the display.
The display switches back to normal mode after five seconds.
Operation 4
Page 10
10 Operating manual VRT 340f
Symbol Meaning
Heating Hot water Automatic:
The operation of the heating circuit changes between the operation modes Heating and Energy Saving in accordance with the time programme set on the room temperature thermostat.
The operation of the hot water storage cylinder changes between heating up and OFF according to the time programme set on the regulator. The hot water symbol is displayed if the time window is active.
Heating:
The heating circuit is operated according to the room temperature, regardless of the programme set on the room temperature thermostat.
Energy Saving:
The heating circuit is operated according to the energy saving temperature "ECO“, regardless of the programme set on the room temperature thermostat.
4 Operation
Page 11
11GBOperating manual VRT 340f
Symbol Meaning
Heating Hot water Off:
Off:The heating circuit is off, provided that the frost protection function (if the room temperature is below 5°C) is not activated.
The boiler is not heated up, regardless of the set timer programme. The hot water symbol is not displayed.
Table 4.1 Operating modes
Operation 4
Page 12
12 Operating manual VRT 340f
4.2 Setting the current day and
time
To set the current time and day of the week with the display in normal mode, you must perform the following steps:
• Press the dial until a day of the week starts flashing.
• Turn the dial until you see the current day of the week. MO = Monday TU = Tuesday WE = Wednesday TH = Thursday FR = Friday SA = Saturday SU = Sunday
• Press the dial. The hours start flashing.
• Turn the dial until the required hour is displayed.
• Press the dial. The minutes start flashing.
• Turn the dial until the required minutes are displayed.
The display switches back to normal mode after five seconds. If the calendar is activated on the installer level, you can set the day, month and year in the same way after you set the time. This allows automatic switching from winter to summer time.
4 Operation
Page 13
13GBOperating manual VRT 340f
4.3 Setting the heating times
T
he room temperature thermostat is
equipped with a basic program (see table
4.2).
Time window
Current day / Block of days
Start time
End time
H 1 M0 - FR 6:00 22:00 H 2 — H 3 — H 1 SA 7:30 23:30 H 2 — H 3 — H 1 SU 7:30 22:00 H 2 — H 3
Table 4.2 Default basic programme - heating
You can adapt the default basic programme to suit your needs. There are five steps to setting the times you want.
1. Press the programming button P
2. Select the timer programme (heating or hot water).
3. Select the time window
4. Select the current day or week block
5. Set the start time.
6. Set the end time.
You can define three time windows for each day.
Operation 4
Page 14
14 Operating manual VRT 340f
For clarification, the individual steps are shown again in the following table:
Display Required steps
Press the programming button P. The cursor (black triangle) marks the value which can be changed (
), which also flashes. Turn the dial until the tap symbol appears.
Press the dial. The cursor marks the value which can be changed (H1), which also flashes. Select the desired time window by turning the dial. Settings: H1, H2, H3
Display Required steps
Press the dial. The cursor marks the week block display, which also flashes. Select a block programme or a single day of the week by turning the dial. Settings: MO - SU MO - FR SA - SU MO = Monday TU = Tuesday WE = Wednesday TH = Thursday FR = Friday SA = Saturday SU = Sunday
4 Operation
Page 15
15GBOperating manual VRT 340f
Display Required steps
Press the dial. The cursor marks the start time and the hour display flashes. Select the start time by turning the dial. Press the dial again to set the minutes.
Press the dial. The cursor marks the end time and the hour display flashes. Select the end time by turning the dial. Press the dial again to set the minutes.
Table 4.3 Setting time windows
If necessary, you can switch the room temperature thermostat from the week programme to a daily programme.
• With the display in normal mode, press the F button for about 10 seconds. When you programme time windows, days of the week will no longer be displayed.
4.4 Setting the room temperature
The current room temperature is shown in the basic display. You can set the room temperature directly from the basic display. You can also set or change the set-back temperature "ECO“ in the basic display.
Operation 4
Page 16
16 Operating manual VRT 340f
Setting the required room temperature directly
• Turn the dial (with the display in normal mode).
The set temperature display disappears, the sun symbol is displayed in the operating mode level and the set room temperature is displayed in the multi­function level (e.g. TEMP 20 °C).
• You can set the required room temperature directly (after about 1 second) to the desired value by turning the dial.
The display switches back to normal mode after five seconds.
Setting the set-back temperature "ECO“
• Press the dial several times until ECO appears in the multifunction display along with a set value. The set-back temperature is displayed and starts flashing.
• Turn the dial until the required set­back temperature is displayed (e.g. ECO 15,0 °C).
The display switches back to normal mode after five seconds.
4.5 Activating special functions
You can access the special functions using the F button. You can activate the following functions:
4 Operation
Page 17
17GBOperating manual VRT 340f
Display Required steps
Quick veto
The quick veto function allows you to adjust the room temperature for a short time (until the next time window). Press the special function button F - the quick veto symbol appears in the display along with the quick veto room temperature. Turn the dial until the quick veto temperature you want is displayed. The display switches back to basic mode after 10 seconds and the function is activated. To deactivate the function, all you need to do is press the F button.
Display Required steps
Party function
When you activate the party function the heating phase is continued beyond the next set­back phase. Press the special function button three times
- the party symbol flashes in the display for ten seconds and the function is activated. The function is deactivated automatically by reaching the next heating phase. If you want to deactivate the function before, just press the F button. This function can only be activated in automatic mode
.
Operation 4
Page 18
18 Operating manual VRT 340f
Display Required steps
Holiday function
The holiday function deactivates the controller, but not the frost protection function. Press the special function button three times - the holiday function symbol flashes in the display. Turn the dial until the required number of day's holiday appears. After 10 seconds the function is activated and the mode is set to OFF for the selected period (see 4.1). If you want to deactivate the function before, just press the F button.
Table 4.4 Special functions
4.6 Info level
Press the info button to access the info level. The info symbol appears in the display as soon as you open the info level. Each time you press the button, different information is displayed:
- The name of the room temperature thermostat (VRT 340f )
- The quick veto room temperature (if active)
- The required room temperature (e.g. TEMP 20.0 °C)
- The current set-back temperature (e.g. ECO 15.0 °C)
4 Operation
Page 19
19GBOperating manual VRT 340f
- The day/month/year (if the calendar is activ
ated)
- The timer programmes set for heating (every single time window per day)
4.7 Changing the battery
The regulator checks the battery condition itself, and the normal working life of the battery is approx. 1.5 years. Approx. 4 weeks before the battery is fully discharged BATT appears in the multifunction display of the basic display. The battery chamber is located on the back of the regulator. The regulator must be taken off the wall plinth to change the battery.
• Carefully push the locking hook to the side using a screwdriver (Fig. 4.1) and pull the regulator off towards the front.
Fig. 4.1 Releasing the locking hook
Operation 4
Page 20
20 Operating manual VRT 340f
• The batteries can now be changed (2x AAA-LR03; Fig. 4.2). Make sure that the polarity of the batteries is correct.
Fig. 4.2 Changing the batteries
If the batteries are not changed in time, the regulator switches over to operating mode "Heating"
, to prevent the
installation from freezing up.
5 Manufacturer’s warranty
and liability
Vaillant warranty
We only grant a Vaillant manufacturers warranty if a suitably qualified engineer has installed the system in accordance with Vaillant instructions. The system owner will be granted a warranty in accordance with the Vaillant terms and conditions. All requests for work during the guarantee period must be made to Vaillant Service Solutions (0870 060 777).
4 Operation, 5 Works guarantee and liability
Page 21
21GBOperating manual VRT 340f
6 Recycling and disposal
Both your Valliant room temperature thermostat VRT 340f and its packaging consist mainly of recyclable raw materials.
Appliance
Do not dispose of your Valliant room temperature thermostat or any of its accessories with the household waste. Make sure the old appliance and any accessories are disposed of properly.
Packaging
Please leave the disposal of the transport packaging to the qualified servicing company which installed the appliance.
Recycling and disposal 6
Page 22
22 Installation instructions VRT 340f
Installation instructions
7 Notes on the installation
and operation
The assembly, electrical connection and the settings in the device as well as the commissioning must be carried out only by a suitably qualified heating engineer. Check the site of installation before fitting the unit with regard to possible radio interference by electrical equipment or building influences which may affect the functioning. If the radio signal route is compromised then an alternative installation site must be chosen.
7.1 CE label
The CE label shows that the VRT 340f room temperature thermostat, when connected to Vaillant boilers, meets the basic requirements of the Council of Europe's directive 89/336/EEC on electromagnetic compatibility and the low voltage directive 73/23/EEC.
7 Information on installation and operation
Page 23
23GBInstallation instructions VRT 340f
7.2 Intended use
T
he VRT 340f room temperature thermostat is a state-of-the-art appliance which has been constructed in accordance with recognised safety regulations. Nevertheless, there is still a risk of death or serious injury to the user or others or of damage to the device and other property in the event of improper use or use for which it is not intended. The VRT 340f room temperature thermostat is designed to control a heating system with or without a hot water system or circulation pump according to time and location, in connection with Vaillant modulating heating equipment.
The connection between the room temperature thermostat and the heating unit is by radio. Any other use or extended use is considered to be improper. The manufacturer or supplier is not liable for any resulting damage. The user alone bears the risk. Use includes observance of the operating and installation manuals and all other applicable documents, as well as adherence to the maintenance and inspection conditions.
Caution!
Any improper use is forbidden.
Information on installation and operation 7
Page 24
24 Installation instructions VRT 340f
8 Safety instructions and
regulations
The unit must be installed by a suitably qualified heating engineer, who is responsible for adhering to the existing standards and regulations. We accept no liability for any damage caused by failure to observe these instructions.
8.1 Safety instructions
Danger!
Risk of fatal electric shock from touching live connections. Before working on the appliance, turn off the power supply and secure against restart. Only remove the room temperature thermostat from the wall mounting or from the plinth when it is potential free.
8 Safety instructions and regulations
Page 25
25GBInstallation instructions VRT 340f
8.2 Regulations
Us
e standard commercial cables for
wiring.
- Minimum cross-section of the wires:
0.75 mm
2
The room temperature thermostat may only be installed in dry rooms.
All wiring must be in accordance with Building Regulations Part P and BS 7671 (IEE Wiring Regulations), and must be carried out by a suitably qualified per­son.
9 Installation
9.1 Place of installation
The room temperature thermostat must be installed to ensure that it can properly record the room temperature (away from heat traps, not mounted on cold walls etc.). The best place for installation is usually in the main living room on an inside wall at approx. 1.5 m height. There, the room temperature thermostat should able to record the circulating air, unhindered by furniture, curtains or other objects. Choose a location where the room temperature thermostat is not affected by draughts from doors or windows,
Safety instructions and regulations 8, Installation 9
Page 26
26 Installation instructions VRT 340f
or by heat sources such as radiators, chimney walls, televisions and direct sunlight. All the radiator valves in the room where the thermostat is installed must be fully open.
9.2 Fitting the receiver
The connection of the receiver with the heating unit is by a plug connector having four connections.
• Remove the blanking plate (1) in the
front of the switchgear cabinet and insert the receiver (2) into the chute which is revealed so that the pins on the back of the upper section fit into the receptacles.
• Push the receiver into the chute until it clicks in position.
bar
bar
2
1 3
0
VRC-VCC
-2
-3
VRC-VCC
-2
-3
2
1
Fig. 9.1 Heating unit and fitting the receiver in
the switchgear box
8 Safety instructions and regulations, 9 Installation
Page 27
27GBInstallation instructions VRT 340f
9.3 Mounting the room temperature thermostat
Check the site of installation before fitting the unit with regard to possible radio interference by electrical equipment or building influences which may affect the functioning. If the radio signal route is compromised then an alternative installation site must be chosen.
• Pull the room temperature thermostat
(1) off the wall plinth (3).
• Drill two holes (2) of 6 mm diameter
(as shown in fig. 9.2) and put in the supplied wall plugs.
• Attach the wall plinth to the wall with
the two screws provided.
• Insert the batteries supplied into the battery compartment at the back of the regulator (Fig. 9.2, Item 4). Make sure that the polarity of the batteries is correct.
Installation 9
Page 28
28 Installation instructions VRT 340f
1
2
4
3
Fig. 9.2 Mounting the room temperature
thermostat
10 Electrical installation
The electrical connection may only be carried out by a suitably qualified heating engineer.
Danger!
Risk of fatal electric shock from touching live connections. Before carrying out work on the controller, switch off the power supply and secure it against being switched on again.
9 Installation, 10 Electrical installation
Page 29
29GBInstallation instructions VRT 340f
10.1 Connecting the receiver
T
he boiler is controlled via a four-core connecting cable. After correct insersion of the receiver into the front of the switchgear box, the room temperature thermostat is ready for operation. Also follow the instructions for the boiler. Do not remove the jumper between terminals 3 and 4 on the boiler.
11 Start-up
Certain system parameters have to be set in order for them to comply with the prevailing conditions. These system parameters are all together on one operating level and should only be set by the heating engineer. The service/diagnostics level is also intended for the engineer and is designed to help during servicing. The receiver is fitted with three status LEDs which provides the following information to the system:
Electrical installation 10, Start-up 11
Page 30
30 Installation instructions VRT 340f
LED Display Condition Function
green
OK
ON normal function off Fault (e.g. no power supply or fault see red LED)
no radio signal
flashing No radio connection with the sender for more than one hour (e.g. poor
connection, weak battery in the sender...) Operation in frost protection function:
- Hot water function switched on:
- Setting point for heating mode: 50 °C
red off normal function
flashing Manual mode:
- Hot water function switched on
- Setting point for heating mode: 50 °C (the manual mode automatically switches to normal mode if a correct radio connection is made with the sender.
yellow flashing Radio connection is made with the sender
Table 11.1 Status display of the receiver
11 Start-up
Page 31
31GBInstallation instructions VRT 340f
Use the button to switch from automatic to manual operation in the event of a fault. The hot water system is released and the feed temperature set value for the heating is 50 °C. Manual operation mode is retained until the next time the radio signal is received.
11.1 Installer level
Press the P button to access the installer level.
• Press the P button for approx. 10
seconds. The spanner symbol and the first parameter appear in the display.
• Press the dial. You can select all the
system parameters in turn.
Turn the dial to set the values you want. When you press the P button the display returns to basic mode.
Start-up 11
Page 32
32 Installation instructions VRT 340f
You can select and change the following parameters:
Display Set by turning the dial
Set-back temperature
Factory setting: 15 °C Setting range: 5 ... 30° C
Correction of current room temperature
Adjustment of the displayed value by up to max. +/- 3 °C Factory setting: 0 °C
Display Set by turning the dial
Two-point/analogue operation
2-point/analogue mode change-over. The room temperature thermostat is set in the factory as a 2-point regulation system (set value 0). You can set it to analogue mode by changing the parameter to 1.
11 Start-up
Page 33
33GBInstallation instructions VRT 340f
Display Set by turning the dial
Control characteristics/ route adjustment
For optimum adaptation to the room size or radiator configuration Factory setting: 0 Adjustment range: -5 ... +5 (positive values: slow reaction speed of the room temperature thermostat; negative values: faster reaction speed of the room temperature thermostat)
Display Set by turning the dial
Day setting
For activation of the calendar
Month setting
For activation of the calendar
Year setting
For activation of the calendar
Table 11.2 System parameters
Start-up 11
Page 34
34 Installation instructions VRT 340f
11.2 Service/diagnostics level
Access the service/diagnostics level by pressing the P button and the dial.
• Press the P button and the dial
simultaneously for approx. 3 seconds. First, a heating request for 50 °C is triggered to test communication with the boiler. Then you can select all the test options by pressing or rotating the dial. When you press the P button the display returns to basic mode.
11 Start-up
Page 35
35GBInstallation instructions VRT 340f
You can select the following tests:
Dial Test Test procedure
Press and push P button for 3 seconds.
Heating request A preset value of 50°C is simulated. The burner on the boiler
starts up and the pump starts (only up to the maximum supply temperature of the boiler).
Press Radio route Display RF On
Press Display test All display elements are displayed.
Press Software version The software version is displayed.
Table 11.3 Service/diagnostic level
Start-up 11
Page 36
36 Installation instructions VRT 340f
Restoring the default settings
• To restore the controller to its default
condition, press the P button for 15
seconds.
11.3 Handing over the appliance to
the owner
The owner of the room temperature thermostat must be instructed about its functions and how to operate it.
• Hand over the manuals intended for
the owner as well as the documents of
the appliance.
• Go through the operating manual with
him and answer his questions.
• Draw special attention to the safety instructions which the owner must follow.
• Tell the owner to keep the manuals near the room temperature thermostat.
11 Start-up
Page 37
37GBInstallation instructions VRT 340f
12 Troubleshooting
The room temperature thermostat signals the following fault conditions:
Fault signal Meaning Troubleshooting
RF Err No radio connection to the radio
receiver on the heating unit
Check the site of installation
BATT low battery condition, replacement
required
Replace the batteries.
Table 12.1 Fault signals
Troubleshooting 12
Page 38
38 Installation instructions VRT 340f
13 Technical data
Description Unit Sender Receiver
Operating voltage V 3V (2xAAA) 24 Maximum permissible ambient temperature °C 50 50 Battery working life Months approx. 18 Transmission frequency MHz 868,35 868,35 Transmission capacity mW 0,5 Current consumption mA
1 (readiness) 15 (readiness) Minimum cross-section of the connection lines mm2 0,75 Level of protection IP 20 IP 20 Protection rating for regulator III III
Dimensions Height/width/depth mm 97/146/27 85/148/30
Table 13.1 Technical data
13 Technical data
Page 39
39GBInstallation instructions VRT 340f
14 Vaillant Service
Vaillant Service
To ensure regular servicing, it is strongly recommended that arrangements are made for a Maintenance Agreement. Please contact Vaillant Service Solutions (0870 6060 777) for further details.
Vaillant Service 14
Page 40
0020029346_00 GB 07 2006
Vaillant Ltd
Vaillant House Medway City Estate Trident Close Rochester Kent ME2 4EZ Tele
p
hone 01634 292300 Fax 01634 290166 www.vaillant.co.uk info@vaillant.co.uk
Loading...