Usl DAX-802 Instruction Manual

DAX-602/802
Digital to Analog Converter
INSTRUCTION
MANUAL
181 Bonetti Drive
San Luis Obispo CA 93401
Ph. 805-549-0161
email: uslinc@uslinc.com
www
.uslinc.com
Warranty ..........................................................................3
Safety Instr
uctions...........................................................4
DAX Background..............................................................5
Front Panel Designations ................................................6
Rear Panel Designations.................................................6
Delay Settings..................................................................7
Channel Assignments .....................................................7
Difference Between 602, 802 .........................................7
AES Channel Assignments .............................................8
Connector Tables........................................................9-10
Software:
lntroduction-Configuration.............................................10
DHCP/NETBIOS.................................................................10
Configuration Page.........................................................11
Surround Delay .............................................................12
Auditorium Data.............................................................12
Password Change..........................................................12
Firmware Update ...........................................................13
Restoring Factory Defaults ............................................14
TABLE OF CONTENTS
DAX-602/802 INSTRUCTIONAL MANUAL
Ultra
H Stereo Labs, Inc.
One Year Limited Warranty
HHHHH
DAX-602/802 INSTRUCTIONAL MANUAL
Ultra
H Stereo Labs, Inc.
USL, lnc. warrants that each product manufactured by it will be free from defects in material and workmanship under normal usage for a period of one (1) year after its purchase new from an authorized dealer. Our obligation under this warranty is limited to repairing or replacing any product or component which, we are satisfied does not conform with the foregoing warranty and which is returned to our factory, freight paid, or serviced by one of our authorized contractors. The forgoing warranty 'is exclusive and in lien of all other warranties, whether expressed or implied. Such warranty shall not apply to any product or component (A) repaired or altered by anyone other than USL, Inc. or an authorized service contractor, (B) tampered with or altered in any way or subjected to misuse, negligence or accident or (C) which has been improperly connected installed or adjusted other than in accordance with USL, Inc.'s instruction.
- 3 -
Important Safety Instructions
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9) Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
10) Only use attachments/accessories specified by the manufacturer.
11) Unplug this apparatus during lightning storms or when unused for long periods of time.
12) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
13) WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
14) DO NOT EXPOSE TO DRIPPING OR SPLASHING. DO NOT PLACE OBJECTS FILLED WITH LIQUID, SUCH AS VASES,ON THIS APPARATUS.
WATCH FOR THESE SYMBOLS:
DAX-602/802 INSTRUCTIONAL MANUAL
Ultra H Stereo Labs, Inc.
The lightning bolt triangle is used to alert the user to the risk of electric shock.
The exclamation point triangle is used to aler
t the user to
Impor
tant operating or maintenance instr
uctions.
!
- 4 -
DAX Background
The DAX unit was designed as a simple Digital to Analog Converter which would accept up to 10AES-EBU conforming signals and convert them into multi­channel analog audio. There are two versions available. The DAX-802 converts 5 screen channels, 2 surrounds and the subwoofer/LFE. The DAX-602 is almost the same but does not convert LC and RC screen channels. Both versions convert the Hearing Impaired/Visual Narration channels without sacrificing any of the normal cinema channels. The output of the DAX unit may connect to any cinema processor that has a multi-channel analog input.
Additionally, the surround channels may be delayed by up to 150ms to accommodate different size theaters.
DAX-602/802 INSTRUCTIONAL MANUAL
Ultra H Stereo Labs, Inc.
ACTIVE
Ls/Rs
DELAY/MS
Although the DAX unit is designed to be a stand atone type of device, a web browser can be used to monitor and control the device.
20
40
120
140
100
80
60
0
- 5 -
Loading...