USL CM-10 User Manual

CM SERIES
Ten Channel
Monitor / Crossover
181 Bonetti Drive San Luis Obispo, CA 93401 ph: 805-549-0161 fax: 805-549-0163 e-mail:usl@uslinc.com
One Year Limited Warranty
USL, Inc. warrants that each product manufactured by it will be free from defects in material and workmanship under normal usage for a period of one (1) year after its purchase new from an authorized dealer. Our obligation under this warranty is limited to repairing or replacing any product or component which we are satisfied does not conform with the foregoing warranty and which is returned to our factory, freight paid, or serviced by one of our authorized contractors. The forgoing warranty is exclusive and in lieu of all other warranties, whether expressed or implied. Such warranty shall not apply to any product or component (A) repaired or altered by anyone other than USL, Inc. or an authorized service contractor; (B) tampered with or altered in any way or subjected to misuse, negligence or accident or (C) which has been improperly connected installed or adjusted other than in accordance with USL, Inc.’s instruction.
Table of Contents
Introduction .........................................................4
Front Panel Description........................................5
Rear Panel Description.........................................7
Installation............................................................9
Monitor and Bargraph Setup...............................13
Monitor and bargraph Levels..............................14
Specifications.....................................................15
Pinouts...............................................................17
Please record the following information for your records: Model: ___________________ Serial Number: ___________ Date of Purchase: ________________ Purchased from: ____________________________________
Introduction
Please read this entire manual before commencing your installation.
The Ultra Stereo CM Series Projection Booth Monitor has been designed for high performance, ease of use, and years of trouble free service. Installation and setup of the monitors has been considerably simplified. No special tools are required. The built in VU meter and test jack give the technician immediate information about the status of the processor and all power amplifiers. All controls necessary for daily operation of the processor are easily accessible on the front panel. The components that make up the CM Series monitors are of computer grade for reliability. All front panel controls are individually sealed for long life. All Ultra Stereo equipment has been “burned-in” at the factory for an extended period in order to eliminate the possibility of premature failure. Unpack the unit carefully. If the container has been damaged, thoroughly inspect the equipment to make certain that there is no hidden damage. File a claim immediately with the carrier if any damage is found. Also advise your dealer or the factory.
TOOLS REQUIRED
Trimpot
adjustment
tool
Small, standard
screwdriver
No. 2 Phillips
screwdriver
Wire
Strippers
You will need to supply the following materials:
• Shielded audio cable for connecting the CM Series to the cinema processor and power amplifier outputs.
• Four 10-32 x 1/2" screws to mount the CM Series in the audio equipment rack.
FEATURES
The CM Series monitor has the following standard features:
• Ten-Channel Monitoring - allows you to monitor either the processor or power amplifier outputs to left, left center, center, right center, right,surround left, surround right, back surround left, back surround right and subwoofer channels, in any combination via the switches on the front panel (see illustration on pg. 5)
• Input levels from processor and power amplifier can be adjusted independently - no huge level jumps when switching between processor and power amplifiers.
• Bargraph display may be calibrated to the reference level for your theatre – the projectionist can see auditorium levels instantly.
• Designed to work with bi or tri-amplified sound systems to monitor the high, mid and low frequency outputs from the left, left center*, center, right center* and right channels.
• Line output for remote monitoring with an external amplifier and speaker.
*Left center, right center only available with inst allation of optional card.
9
7 8 6
5
4
3
2
1. Channel select buttons - pressing a Channel Select Button causes the corresponding LED to illuminate
and the signal from that channel to be monitored. Any combination of ten channels can be selected.
2. Internal Digital or Analog Crossover Access Cover.
3. Crossover Bypass Switch - Switching this will cause the internal crossover to be bypassed or engaged
and the condition will be indicated by its appropriate LED.
4. Volume Control - controls the volume of the internal speaker and test jack (7). The volume control
has no effect on the VU Bargraph display.
5. Processor/Amplifier Selector Switch - selects either the inputs from the cinema processor or power
amplifiers for monitoring.
6. VU Bargraph - displays the level of the selected channels. The VU Bargraph may be calibrated by
the rear panel trim adjustment (Figure 2). The VU Bargraph operates independently of the volume
control (4).
7. Test Jack - permits monitoring of the audio output of the CM Series. Inserting a mono or stereo 1/4”
1
phone plug here disables the internal speaker and routes the audio output to the Test Jack. Do
not connect any device here with less than 8 Ohms impedance.
8. Internal Speaker
9. Power Switch
Loading...