KM900CO/P • Combustion Analyzer
Copyright © 2007 UEi Specifications are subject to change without notice. L773 1/07
Distributed By:
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: info@ueitest.com
IN CANADA
Vancouver: Phone: 1-877-475-0648 • (604) 278-4511 • Fax: (604) 278-8299
Toronto: Phone: 1-877-475-0648 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
The KM900CO/P hand-held range of analyzers
are easy to use for domestic and industrial flue gas
measurement and analysis. They operate on all
boiler types and display up to eight parameters
simultaneously, showing measurements and
calculations of boiler efficiency and pollution.
KM900CO/P has enough memory to store up to
150 readings and can transfer data to a printer or
PC. The printout displays the time and date of each
measurement as well as personalized information
such as company name and telephone number.
The KM900CO/P
has the following features:
• Measures O2 and CO
• Calculates CO2, efficiency and excess air
• 0 to 10,000 ppm H2 compensated CO sensor
• Large 4 line display
• Long life rechargeable battery
• Large cordura case
• 150 memory positions
• One year limited warranty
• Two year limited warranty on O2 sensor
Standard Accessories:
Battery Charger/Main Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMCU900/110
Flue Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMCP10
Water Trap/Particle Filter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .WT700
Replacement Particle Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16345
Optional Accessories:
Infrared Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMIRP2
Pressure Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMPS4
Communications & Graphing Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMFR1
Optional Sensor Upgrades
• NO Sensor for NOx Measurement
• Pressure Sensor for Draft Measurement
Specifications
Parameter Resolution Accuracy Range
Temp. Measure m e n t
Flue Measurement 1. 0 ˚ F / C ±2.0˚F/C, ±0.3% of rdg 32˚ - 1112 ˚ F
with probe (0˚ - 600˚C)
Inlet Te m p e r a t u r e 0 .1 ˚ F / C ± 1.0˚F/C, ±0.3% of rdg 32˚ - 122 ˚ F
(0˚ - 50 ˚ C )
Gas Measure m e n t
Oxygen (02) 0 .1 % ± 0 . 2 % 0 - 21 %
Carbon Monoxide (CO ) 1 ppm, mg/m3± 2 0 ppm <400 ppm 0 - 4000 ppm
±5% >400 ppm 0 - 5000 mg/m
3
Nitric Oxide (NO) 1 ppm, mg/m3±5 ppm <100 ppm 0 - 5000 ppm
( o p t i o n a l )
D r aught (optional) 0 .1 mbar ±5.0% full sca l e 0 .150 mbar
Carbon Dioxide (CO2) 0 .1 % ±0.3% reading 0 - 99.9%
Lo s s e s 0 .1 % ± 1 .0% reading 0 - 99.9%
E f f i c i e n c y 0 .1 % ± 1 .0% reading 0 - 99.9%
Excess Air 0 .1 % ± 0 . 2 % 0 - infinite
Temp. (Net) 1. 0 ˚ F / C ± 12˚F/C, ±0.3% of rdg 32˚ - 1112 ˚ F
(0˚ - 600˚C)
CO / CO2ra t i o 0 . 0 0 01 % ± 0 . 0 0 01% rdg 0 - 0.9999%
Poison index 0 . 01 + 0 . 01 0 - 99.9
P r e - p r o g rammed fuels N a t u ral gas, Town gas, Gascor, light oil, heavy oil, Propane,
Butane, Anthrocite, Coke, Coal, KM sales gas, 2 user fuel choices
D i m e n s i o n s
We i g h t 2.2 pounds
H a n d s e t 8.8” x 2.2” x 4.8”
P r o b e 16.5” x 0.3” Dia. with stainless steel shaft, type K thermocouple
and 5’ neoprene hose
Ambient Opera t i n g 32˚ - 104˚F (0˚ - 40˚C)
R a n g e 20% to 80% RH non condensing
Power Supply Input: 110V AC/ 220V AC nominal
( b a t t e ry charger) Output: 12V AC off load
B a t t e ry Life >8 hours from full charge
PLEASE