Universal Enterprise KM900CO User Manual

Page 1
MAXIMIZE COMBUSTION
P
ERFORMANCE
& S
AFETY
KM900CO/P
Combustion A n a l y z e r
Measures O2 and CO
0 to 10,000 ppm H2 compensated CO sensor
Large 4 line display
Long life rechargeable battery
Large cordura case
150 memory positions
Page 2
KM900CO/P • Combustion Analyzer
Copyright © 2007 UEi Specifications are subject to change without notice. L773 1/07
Distributed By:
1-800-547-5740 • Fax: (503) 643-6322 www.ueitest.com • Email: info@ueitest.com
IN CANADA
Vancouver: Phone: 1-877-475-0648 • (604) 278-4511 • Fax: (604) 278-8299 Toronto: Phone: 1-877-475-0648 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
The KM900CO/P hand-held range of analyzers are easy to use for domestic and industrial flue gas measurement and analysis. They operate on all boiler types and display up to eight parameters simultaneously, showing measurements and calculations of boiler efficiency and pollution.
KM900CO/P has enough memory to store up to 150 readings and can transfer data to a printer or PC. The printout displays the time and date of each measurement as well as personalized information such as company name and telephone number.
The KM900CO/P has the following features:
• Measures O2 and CO
• Calculates CO2, efficiency and excess air
• 0 to 10,000 ppm H2 compensated CO sensor
• Large 4 line display
• Long life rechargeable battery
• Large cordura case
• 150 memory positions
• One year limited warranty
• Two year limited warranty on O2 sensor
Standard Accessories:
Battery Charger/Main Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMCU900/110
Flue Probe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMCP10
Water Trap/Particle Filter Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .WT700
Replacement Particle Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16345
Optional Accessories:
Infrared Printer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMIRP2
Pressure Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMPS4
Communications & Graphing Software . . . . . . . . . . . . . . . . . . . . . . . . . . . .KMFR1
Optional Sensor Upgrades
• NO Sensor for NOx Measurement
• Pressure Sensor for Draft Measurement
Specifications
Parameter Resolution Accuracy Range
Temp. Measure m e n t
Flue Measurement 1. 0 ˚ F / C ±2.0˚F/C, ±0.3% of rdg 32˚ - 1112 ˚ F with probe (0˚ - 600˚C) Inlet Te m p e r a t u r e 0 .1 ˚ F / C ± 1.0˚F/C, ±0.3% of rdg 32˚ - 122 ˚ F
(0˚ - 50 ˚ C )
Gas Measure m e n t
Oxygen (02) 0 .1 % ± 0 . 2 % 0 - 21 % Carbon Monoxide (CO ) 1 ppm, mg/m3± 2 0 ppm <400 ppm 0 - 4000 ppm
±5% >400 ppm 0 - 5000 mg/m
3
Nitric Oxide (NO) 1 ppm, mg/m3±5 ppm <100 ppm 0 - 5000 ppm ( o p t i o n a l ) D r aught (optional) 0 .1 mbar ±5.0% full sca l e 0 .150 mbar Carbon Dioxide (CO2) 0 .1 % ±0.3% reading 0 - 99.9% Lo s s e s 0 .1 % ± 1 .0% reading 0 - 99.9% E f f i c i e n c y 0 .1 % ± 1 .0% reading 0 - 99.9% Excess Air 0 .1 % ± 0 . 2 % 0 - infinite Temp. (Net) 1. 0 ˚ F / C ± 12˚F/C, ±0.3% of rdg 32˚ - 1112 ˚ F
(0˚ - 600˚C) CO / CO2ra t i o 0 . 0 0 01 % ± 0 . 0 0 01% rdg 0 - 0.9999% Poison index 0 . 01 + 0 . 01 0 - 99.9 P r e - p r o g rammed fuels N a t u ral gas, Town gas, Gascor, light oil, heavy oil, Propane,
Butane, Anthrocite, Coke, Coal, KM sales gas, 2 user fuel choices D i m e n s i o n s We i g h t 2.2 pounds H a n d s e t 8.8” x 2.2” x 4.8” P r o b e 16.5” x 0.3” Dia. with stainless steel shaft, type K thermocouple
and 5’ neoprene hose Ambient Opera t i n g 32˚ - 104˚F (0˚ - 40˚C) R a n g e 20% to 80% RH non condensing Power Supply Input: 110V AC/ 220V AC nominal ( b a t t e ry charger) Output: 12V AC off load B a t t e ry Life >8 hours from full charge