Unified Brands Avtec 2000, EA2-DDLLL-30 User Manual

The Avtec EcoArch 2000 Series
Model Number Hood Section Dimensions Application CFM/Ft
The Most Energy Efficient Ventilation System.
The Avtec EcoArch combines both an economical and environmentally safe solution for the need for high-quality, cost­eective ventilation performance in today’s foodservice kitchens.
The EcoArch ventilation system addresses the growing need to reduce the amount of conditioned air from a kitchen space. The combination of the patent pending arch top and the front mounted high velocity exhaust slot reduces the amount of exhausted CFM by 45% compared to traditional CFM rates. This translates into an annual
electric and gas savings of up to 40%.
EA2-DDLLL-30
EA2-DDLLL-30
 DD = Depth in inches, LLL=Length in inches, 30=Height in inches. Example: EA2-54120-30 stands for a 54” deep x 120” long x 30” high unit.  For hood lengths longer than 192”, multiple sections can be grouped together.  Minimum CFM may vary based on cooking equipment application.
Available length of 48” to 192”
x 30” high
Available length of 48” to 192”
x 30” high
600˚F 150
400˚F 130
Constructed of High Grade Non-Corrosive Stainless Steel
Up to 40% Annual Energy Savings Using Exclusive Design Features
Exclusive Aerodynamic Arch – Dramatically reduces the amount of turbulence
within the canopy reservoir. About 70% of the contaminated air is exhausted immediately out of the reservoir.
High Velocity Exhaust Slot – The higher rate of speed at the slot in addition to its
location at the top of the canopy eectively removes the contaminated air working in conjunction with the arch top.
Easier and Safer Removal of Filter Medium
Unlike tradition rear lter locations, EcoArch exhaust plenum and lters are located in the front of the hood eliminating the need to climb on top of cooking equipment for daily removal and cleaning.
Recessed Fluorescent Light Fixtures
EcoArch comes standard with recessed uorescent light xtures to maximize light foot candles at the cooking surfaces with the least amount of energy consumption.
Now that’s maximizing your energy and cost savings!
Sample Energy Savings
150 cfm/ft (EcoArch) vs. 250 cfm/ft (traditional unit)
12’ Hood, 400°F, Gas & Electric, Based on 2006 Utility Rates
Location cfm/ft Annual Gas Annual Electric Total Energy Annually Savings %
New York, NY 250 $5425 $1364 $6789
New York, NY 150 $3255 $828 $4083
Total Savings $2170 $536 $2706 40%
Atlanta, GA 250 $3728 $943 $4671
Atlanta, GA 150 $2237 $571 $2808
Total Savings $1491 $371 $1863 40%