U-line U1224WCS13B User Manual

USER GUIDE & SERVICE MANUAL
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
1000 Series 1224WC 24" Single Zone Wine Captain® Model
USER GUIDE
u-line.com
Contents
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Intro
Safety
Safety and Warning Disposal and Recycling
Installation
Environmental Requirements Electrical Cutout Dimensions Product Dimensions Side by Side Installation Anti-Tip Bracket General Installation Integrated Panel Dimensions Integrated Panel Installation
Maintenance
Cleaning Cleaning Condenser Wine Rack Installation Extended Non-Use
Service
Troubleshooting Warranty
Service Extended
Wire Diagram Product Liability Warranty Claims Parts Ordering Replacement Parts
Grille / Plinth Installation Door Swing Door Stop Door Adjust Wood Trim Finishing Free Standing Kit
Operating Instructions
First Use Control Operation Sabbath Mode Airflow and Product Loading U-Line Wine Guide Recommended Wine Storage
System Diagnosis Guide Compressor Specifications Troubleshooting Extended Control Quick Guide Thermistor Defrost
USER GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades of premium modular
ice making, refrigeration, and wine preservation experience. U-Line continues to be the American leader, delivering versatility
and flexibility for multiple applications including residential, light commercial, outdoor and marine use. U-Lines complete
product collection includes Wine Captain
Door Refrigerators, Drawer Models, Freezers, Combo® Models, and more.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin and has shipped product to five continents for over
two decades and is proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Spec Sheets, CAD Drawings, Compliance Documentation,
and Product Warranty information are all available for reference and download at u-line.com.
®
Models, Beverage Centers, Clear Ice Machines, Crescent Ice Makers, Glass & Solid
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.800.779.2547
F: +1.414.354.5696
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
Introduction 1
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Safety and Warning
Please read all instructions before installing, operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type:
DANGER
!
Danger means that failure to follow this safety statement will result in severe personal injury or death.
DANGER
!
This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the “R600a specifications” section included in the User Guide. Do not damage the refrigerant circuit.
WARNING
!
Service must be done by factory authorized service personnel. Any parts shall be replaced with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service.
WARNING
!
Warning means that failure to follow this safety statement could result in serious personal injury or death.
CAUTION
!
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
Safety and Warning 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Disposal and Recycling
DANGER
!
RISK OF CHILD ENTRAPMENT. Before you throw
away your old refrigerator or freezer, take off
the doors and leave shelves in place so children
may not easily climb inside.
If the unit is being removed from service for disposal,
check and obey all federal, state and local regulations
regarding the disposal and recycling of refrigeration
appliances, and follow these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Disposal and Recycling 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce
the unit’s ability to reach low temperatures and/or reduce
ice production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (4°C) or below are not covered by the
warranty.
Environmental Requirements 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Electrical
WARNING
!
SHOCK HAZARDElectrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Electrical 1
USER GUIDE
4"
(102 mm)
7"
(178 mm)
24"
(610 mm)
24-1/4"
(616 mm)
34-1/4"
(870 mm)
to
35-1/8"
(892 mm)
Preferred location for electrical outlet is in adjacent cabinet.
5/8"
(16 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cutout Dimensions
PREPARE SITE
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides, or
rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical connection in
the rear.
CAUTION
!
Unit can NOT be installed behind a closed cabinet
door.
CUTOUT DIMENSIONS
Cutout Dimensions 1
USER GUIDE
3-9/16" (91 mm)
34-1/8" to 35-1/8"
23-1/4
" (591 mm)
(Includes
3/4
" [20 mm] Integrated Panel)
24" (610 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Product Dimensions
(867 mm to 892 mm)
Product Dimensions 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the cutout
dimension of a single unit times two.
No trim kit is required. However, 1/4" (6 mm) of space
needs to be maintained between the units to ensure
unobstructed door swing.
Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
electrical specifications requirements.
Side-by-Side Installation with Bracket
1. Slide both units out so screws on top of units are easily
accessible.
3. Place bracket over holes and attach to unit with two
screws removed in step 2 using a T-25 Torx driver.
Tighten screws fully.
4. Gently push units into position. Be careful not to
entangle the electrical cord or water line, if applicable.
5. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The units top
surface should be approximately 1/8" (3 mm) below
the countertop.
2. Remove screws as shown below.
Side-by-Side Installation 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Anti-Tip Bracket
1. Slide unit out so screws on top of unit are easily
accessible.
2. Remove the two screws from the opposite side of the
hinge assembly using a T-25 Torx driver (see below).
NOTE: 1224 models shown with four screws. 1215 models
only have three screws, but same screws are used in both
applications.
FLOOR MOUNTED ANTI-TIP INSTALLATION
1. Locate two anti-tip brackets included in the kit.
2. Place the unit into the area where it will be installed.
Check the door, sides, and top for a proper fit. Also
test to make sure the door opens and closes freely.
3. Remove grille and place a mark on the floor at the
front of the unit. Also place a mark on the floor in the
center of the unit.
3. Place bracket (part #14154) over holes and attach to
unit with two screws removed in step 2 using a T-25
Torx driver. Tighten screws fully.
4. Gently push unit into position. Be careful not to
entangle the electrical cord or water line, if applicable.
5. Check to be sure the unit is level from front to back
and side to side. Make any necessary adjustments.
The units top surface should be approximately 1/8"
(3 mm) below the countertop.
6. Secure bracket into adjoining surface.
Anti-Tip Bracket 1
USER GUIDE
C
L
Back wall
Back of unit
Front of unit
Surrounding
area (Top view)
A
A
B
1024/1224 WC 1215 WC
A 11-1/16" (281 mm) 6-9/16" (167 mm)
B 20-1/4" (514 mm) 20-1/4" (514 mm)
1024/1224 WC 1215 WC
A 11-1/16" (281 mm) 6-9/16" (167 mm)
B 20-1/4" (514 mm) 20-1/4" (514 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
4. Remove the unit. Using a square, extend center line
“B” (see chart below). This line serves as the back
edge for the anti-tip brackets. From the center line,
measure “Ato the left and right. This line is the outer
edge of each bracket.
5. Place the anti-tip brackets on the floor against the line
drawn for the outer edge. Mark spots for the screw
holes.
Surrounding
area (Top view)
Drill holes and
mount anti-tip
Front
of
unit
brackets to floor
B
A
C
A
L
Back
of
unit
Back wall
6. Use a 1/8" drill to make two starter holes and fasten
the anti-tip brackets to the floor using the screws
provided.
7. Place the unit back into position, making sure the feet
engage the anti-tip brackets properly. Check the
alignment of the lines made on the floor in step 3 with
the position of the front feet to ensure proper
positioning.
Anti-Tip Bracket 2
USER GUIDE
1
Turn to Adjust
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
General Installation
LEVELING INFORMATION
1. Use a level to
confirm the unit is
level. Level should
be placed along top
edge and side edge
as shown.
2. If the unit is not level, adjust the legs on the corners of
the unit as necessary.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the cord.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The units top
surface should be approximately 1/8" (3 mm) below
the countertop.
4. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Readjust the front legs to level the unit after it is
correctly positioned in the opening.
General Installation 1
USER GUIDE
NOTICE
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY FRAME FLAT AND WITHOUT INTERFERENCE
2-3/4" (70 mm)
Integrated Frame
3/4" (20 mm)
23-3/4"
(603 mm)
30-1/4" (768 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Integrated Frame
Due to differences in surrounding cabinetry the
panel may not perfectly align with door. The
procedure below is designed to provide a
finished integrated panel that seamlessly
integrates with surrounding cabinetry.
The door panel must not weigh more than 20 lbs
(10 kg).
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardware is installed.
When applying an integrated panel to a unit,
ensure that both sides are finished in order to
prevent warping. In some frame installations,
the panel may be visible through the glass while
the door is open.
2. Optional: Stain or Finish panel to desired stain or color.
Be sure to closely follow the instructions provided by
the manufacturer.
3. Optional: Install handles and hardware.
Integrated Frame Dimensions
A full integrated door panel completely covers the door
frame and provides a built-in appearance.
Integrated Frame Preparation
1. Cut the panels to the dimensions listed in the diagram
below.
Integrated Panel Dimensions 1
USER GUIDE
NOTICE
NOTICE
Align Panel
Against
Door/Drawer
Edge First
Align Top Of Panel With Highest Point Of Door/Drawer
Door
Panel
Integrated Panel
Integrated Panel
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Integrated Panel Installation
1. Fully open door/drawer.
2. Starting at corner, pull
gasket away from door/
drawer.
3. Continue to pull gasket
free from gasket channel.
4. Upon removal, lay gasket down on a flat surface.
5. The panel should be aligned with the outside edge
(opposite the hinge) and high enough to align with the
highest point in the door/drawer.
6. Secure integrated
panel to door/drawer
Bar
Clamp
using clamps. A
robust tape may also
be used. U-Line
recommends the use
of bar clamps to
Door/Drawer
secure the panel to
the door/drawer. If
using tape, be
Wood Panel
certain the tape will
not damage panel
finish upon removal.
7. Using a 7/64" (3 mm)
Bar
Clamp
drill bit, drill 6 pilot
holes into the wood
panel 1/2" (12 mm)
deep using the holes in the door/drawer frame as a
guide.
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
flush with the top of the door/drawer.
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
8. Locate 6 of the #6x 1-1/4" (32 mm) screws provided
with your unit.
9. Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
10.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
the channel.
Integrated Panel Installation 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
11.Remove clamps from door/drawer.
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
completion.
12.Starting at the corners, re-install the gasket into the
gasket channel in the frame. Make sure the gasket is
fully seated. This may take some force.
Integrated Panel Installation 2
USER GUIDE
2
1
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Grille - Plinth Installation
REMOVING AND INSTALLING GRILLE
WARNING
!
Disconnect electric power to the unit before
removing the grille.
When using the unit, the grille (plinth strip/base
fascia) must be installed.
WARNING
!
DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.
Removing the grille
1. Disconnect power to the unit.
2. Loosen the two screws (1).
3. Remove grille (2) from unit.
Installing the grille
1. Align cabinet and grille holes and secure, but do not
over tighten grille screws (1).
2. Reconnect power to the unit.
Grille - Plinth Installation 1
USER GUIDE
Wall Wall
90
Door Swing
90
Door Swing
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Swing
Units have a zero clearance for the door to open 90°,
when installed adjacent to cabinets.
Stainless Steel and black and white models require 2-1/8"
(54 mm) door clearance to accommodate the handle if
installed next to a wall.
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
knobs or pulls installed on the integrated panel/frame.
Door Swing 1
USER GUIDE
NOTICE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Stop
Your U-Line unit was shipped to you with the optional
90° pin(s). (Models that are 15" wide include 1 pin. Models
that are 24" wide include 2 pins.) The unit’s door will open
freely without a fixed opening angle limitation. If you
would like the door stop at 90° follow these instructions.
The pin is designed to stop the door at 90° under
normal operating conditions. It is not designed
for excessive force. Do not use the door to move
the unit in/out of the cutout during installation.
If your unit is already undercounter, it might
need to be moved out/forward to access the
hinge.
1. Locate the threaded pin.
3. On 24" models, a second pin is included for the bottom
hinge. Repeat steps above for second hinge.
NOTE: Threaded pin will be inserted from the bottom.
4. Carefully slide your unit back in place.
2. With the door between 0° (closed) and 90° and using a
3/32" hex driver, install the threaded pin through the
hinge.
The pin can be removed to return the door swing
back to its original state by unscrewing the
threaded pin.
Door Stop 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing
properly. If the door is not sealed, the unit may not cool
properly, or excessive frost may form in the interior.
Properly aligned, the doors gasket should be
firmly in contact with the cabinet all the way
around the door (no gaps). Carefully examine
the doors gasket to ensure that it is firmly in
contact with the cabinet. Also make sure the
door gasket is not pinched on the hinge side of
the door.
TO ALIGN AND ADJUST THE DOOR
Remove grille:
Remove the grille (see GRILLE-PLINTH INSTALLATION section of this guide).
TO REVERSE THE DOOR
Remove grille:
Remove the grille (see GRILLE-PLINTH INSTALLATION
section of this guide).
Remove top hinge and door:
1. Loosen (do not remove) top and bottom hinge screws.
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
REVERSING THE DOOR
Location of the unit may make it desirable to mount the
door on the opposite side of the cabinet.
The hinge hardware will be removed and installed on the
opposite side of the cabinet.
1. Hold door to keep it from falling.
2. Remove top hinge from cabinet by removing three
screws. Set aside and save for possible future use.
Door Adjustments 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
3. Remove door by tilting forward and lifting door off
bottom hinge. Retain shoulder washers; they will be
reused.
4. Remove four screws from hinge holes on the opposite
side. Reinstall into holes where the hinge was
removed. Take care not to scratch cabinet.
Remove and reinstall bottom hinge:
1. Remove bottom hinge from cabinet by removing three
screws.
3. Rotate gasket 18, aligning notch with magnet
assembly and pressing firmly into the gasket channel
starting at the corners.
4. Rotate door 180° to reverse.
Install top hinge and door:
1. Use alternate hinge supplied with unit and reinstall the
screws. Do not tighten..
2. Lift the door on to the bottom hinge.
2. Remove corresponding screws on opposite side of
cabinet.
3. Flip hinge plate over and reinstall on opposite side.
Prepare door for reinstallation:
1. Remove gasket. This will reveal mounting holes for the
magnet assembly
2. Remove magnet assembly from door with T-10 TORX
driver. Be sure to only remove the two screws holding
the assembly to the door. Reinstall on the opposite end
of the door
3. Align flat edge of the hinge with the outer edge of the
unit.
4. Tighten three screws.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND
ADJUSTMENT).
Install grille:
Install the grille.
Door Adjustments 2
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
SHIFTING WINE RACK SPACERS (OPTIONAL)
Only perform these steps if you require wine
rack clearance with a 90° door opening. Doors
which are allowed to open past 90° do not
require this step.
1. Remove wine rack (see WINE RACK INSTALLATION in
Maintenance).
2. Starting from the side that has the spacers (previously
unaltered units will be on the right hand side from the
factory), remove 2 screws, slide and spacer.
5. Place the spacer in between the liner and slide.
6. Install original hardware.
7. Slide wine rack back into position.
3. Reinstall the slide with the original 2 screws.
4. Remove 2 screws from the other side.
Door Adjustments 3
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Wood Trim Finishing
The wine rack fronts are solid natural beech wood. They
are factory coated with a clear vinyl sealer, which will
sufficiently protect the wood in normal use.
You may coat the trim with stain and/or a final finish to
match surrounding cabinetry.
CAUTION
!
You MUST remove the wood trim from the unit
for staining or finishing to prevent permanent
damage to the inner liner of the unit. Allow stain
or finish to dry thoroughly (at least 24 hours for
each coat) following the product manufacturer’s
instructions before reinstallation. Not following
this warning may cause the inner liner of the
unit to have a permanent odor, which the
warranty will not cover.
U-Line recommends Minwax
and Minwax Polycrylic
Never use oil based stains or finishes.
On glass door models, the stain may appear
darker when viewed through the glass.
Follow the manufacturers instructions for the
stain and/or finish you select.
®
Brand Water Based Stains
®
Protective Finish.
Wood Trim Finishing 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Free Standing Kit
The free standing kit is an optional accessory. It is only
used when unit is not installed in surrounding cabinetry.
To install the kit:
1. Remove grille (see GRILLE-PLINTH INSTALLATION
section).
2. Place shell accessory over front and back of cabinet
base, aligning holes of shell accessory with the holes
on the base. Insert sheet metal screw in back of base.
3. Align front hole with hole in shell accessory, hole in
base, and hole in grille. Tighten screw.
Free Standing Kit 1
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
First Use
All U-Line controls are preset at the factory. Initial startup
requires no adjustments.
U-Line recommends allowing the unit to run
overnight before loading with product. As warm
air rises, the temperature inside the unit tends
to be slightly warmer at the top and slightly
cooler at the bottom.
When plugged in, the unit will begin operating under the
factory default settings. If the unit was turned off during
installation, simply press and the unit will immediately
switch on. To turn the unit off, press .
First Use 1
USER GUIDE
Up Down Light Power
Not
Used LED
or
or
and
and
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Control Operation
CONTROL FUNCTION GUIDE
FUNCTION COMMAND DISPLAY/OPTIONS
ON/OFF Press and release Unit will immediately turn ON or OFF.
Toggle lights
Adjust refrigerator set
point
View temperature in unit Press together and release
Toggle between F/C Hold for 5 seconds The display will change units.
DOOR ALERT NOTIFICATION
When the door is left open for more than 5 minutes:
An audible tone will sound for several seconds every
minute.
dr” will appear in display.
Close door to silence alert and reset.
Press and release to leave interior
light on for 3 hours
Press and release
Glass door wine and beverage centers only.
When the “F” or “C” in the display is flashing, press
to adjust the set point temperature.
The display will flash and then toggle from set point
to temperature in unit.
Control Operation 1
USER GUIDE
12 3456 7
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
L
Sabbath Mode
This unit is Star-K certified and offers a Sabbath mode.
Sabbath mode disables system responses to user initiated
activities and all external functions, including lighting,
display and audible alarms. The unit will still maintain
internal temperatures and set points. View a full list of
Star-K certified U-Line units at www.star-k.org.
To enable Sabbath Mode:
1. Press (4) and hold for ten seconds and release (the
°F/°C symbol will flash briefly at the end of the ten
second period).
2. The interior light and control display (3) will go dark
until user resets mode.
3. NOTE: Although the display will not be visible, the
temperature controls in the unit remain active and
preserve the interior temperature.
Sabbath Mode remains active until (4) is quickly
pressed and released.
Sabbath Mode 1
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Airflow and Product Loading
The unit requires proper airflow to perform at its
highest efficiency. Do not block the front grille,
or the unit will not perform as expected. Do not
install the unit behind a door. When loading your
unit, leave space between the evaporator and
product loaded. Anything in direct contact with
the evaporator is subject to freezing.
When properly loaded, your U-Line unit will store up to 48
(750 ml) bottles of wine.
Airflow and Product Loading 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
U-Line Wine Guide
LOOKING BEHIND THE LABEL
To most, wine is a delicious mystery. We purchase it,
uncork it, and savor its taste and beauty. But there is so
much more to true wine appreciation. Many secrets are
simply too good to keep bottled up.
WINE SELECTIONS SUGGESTIONS
Selecting the right wine for the right occasion can
sometimes be a seemingly awkward or difficult task for
the beginning wine enthusiast. We would therefore like to
present you with a few suggestions which may provide a
little more confidence and enjoyment when choosing and
serving your wines.
When selecting wines, keep an open mind and do not be
afraid to be adventurous. Do not view the subject of wine
so seriously it discourages you from learning and
discovering for fear of embarrassment if something is
incorrect. Wine is best viewed as a hobby and enjoyed.
Guide To Common Styles Of Wine
Red Wines
Full-Bodied Dry California
Medium-Bodied Dry California
Light-Bodied Dry French
White Wines
Full-Bodied Dry California
Medium-Bodied Dry California
Light-Bodied Dry French Chablis, Muscadet,
Full-Bodied, Very Sweet
Medium-Bodied, Semi-Sweet
Light-Bodied Off Dry Germany Rhine, Mosel, Riesling
French Italian
French
Italian
French
French
Germany French Hungary
California Germany
Zinfandel, Cabernet Rhone, Chateauneuf-du- Pape Barbaresco, Barolo
Pinot Noir Bordeaux, Burgundy
Beaujolais Chianti, Bardolino
Chardonnay Montrachet, Meursault Puligny- Montrachet
Sauvignon-Blanc Pouilly-Fuisse, Sancerre, Vouvray, Graves
Pouilly-Fume
Beerenauslese Sauternes Tokay
Gewurtztraminer Liebfraumilch
When assembling your collection, try not to become
obsessed with “Vintages.” Although a chart can be a useful
tool, generalizations about a specific year have led more
than one collector to disappointment. Often an “Off Year”
will provide a better value and more drinking enjoyment.
The primary guideline to the subject of wine is your own
palate. Do not be afraid to make mistakes. Experiment,
discover, but most of all, enjoy yourself and your new U-
Line product.
Matching Food and Wine
Although there are no hard fast rules for matching wine to
food, observe some guidelines. Delicate dishes should be
accompanied by lighter more delicate wines. Full-flavored
foods should be matched with fuller-bodied wines.
As a general rule, one should aim to ascend in flavor and
quality of wines served.
Serve a: Before a:
DRY wine SWEET wine
WHITE wine RED wine
YOUNG wine OLD wine
LIGHT-BODIED wine FULL-BODIED wine
Any step back in quality will be noticed. If a fine wine is
tasted prior to a lesser wine, many of the fine wine’s
subtle qualities may be missed.
U-Line Wine Guide 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
Common Food and Wine Matches
Foods Wines
Fish, Shell Fish, Crab, Oysters Dry White Wines, Light
Beef, Venison Full-Bodied Red Wines
Pork, Veal, Lamb and Poultry Light-Bodied Red Wines
Fruit Sweet White and Sparkling
A Toast to Wine Truths
Like the grapes themselves, many wine myths have been
cultivated over the centuries.
Myth 1: Most wines taste better when aged.
Truth: In fact, less than 5% of wines produced today are
meant to be aged. Most wines are crafted to be consumed
within the first one to two years.
Myth 2: Wines should be uncorked and decanted allowing
them to “breathe.”
Truth: To breathe or not breathe? While it is better to
allow a young tannic Red to breathe in a glass or decanter
to soften the tannins, an old Red reaches a stage in its life
where it should be enjoyed soon after opening. Allow an
old Red to breathe for a short time to dissipate any off
odors. Most white wines can be served, ideally, 10-15
minutes after opening.
Sparkling or Extra Dry
Champagne
Wines
The Cork: A Mystery on Its Own
Cork Presentation. The ritual of the presentation of the
cork has a rich and fascinating history dating back to the
late 1800s. A phylloxera (root louse) devastation to the
vineyards severely limited the supply of great wines.
Restaurateurs would remove labels on inferior wines and
replace them with labels from superior wines. This made it
necessary for patrons to protect themselves by checking
the branding on the cork to ensure that what they ordered
was, in fact, what they were served.
When presented with a cork today, feel it to check for its
integrity, read and match the branding on the cork to the
bottle and set it aside. There is little to be learned from
the cork. The proof is in the wine.
“Corked” wines. If you’ve ever had a wine that smelled or
tasted of mold, you’ve experienced a wine that may have
been “corked.” Today, between five and eight percent of
wines are tainted with Trichloroanisole (TCA). This
substance, found naturally in plants and trees, is imparted
to the wine through the cork. Corked wines are a major
concern for winemakers as it destroys millions of cases
per year and puts reputations at stake. Amazing as it may
seem twist-off caps may offer a better alternative and
many great wineries in California, Australia and New
Zealand are pioneering the trend.
Myth 3: When age worthy wines peak, they must be
consumed almost immediately.
Truth: Most great wines reach a plateau period rather
than a peak. Great Bordeaux’s may have as much as a
10-year plateau before fading.
Myth 4: Wine color does not change with aging.
Truth: As red wines age they get lighter in color while
whites get darker.
U-Line Wine Guide 2
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
Common Tasting Terms IDEAL WINE STORAGE CONSIDERATIONS
Terminology Description
Acidity A critical element of wine that is responsible
for preserving the wines freshness. Excess acidity results in an overly tart and sour wine.
Balance A desired trait where tannin, fruit and acidity
are in total harmony. Wines with good balance tend to age gracefully.
Body The weight and presence of wine in the
mouth provided by the alcohol and tannin level. Full-bodied wines tend to have this strong concentration.
Bouquet The blending of a wine’s aroma within the
bottle over a period of time, caused by volatile acidity.
Complex A subjective term often used in tasting. A
wine is said to be complex if it offers a variety of flavors and scents that continue to evolve as it develops.
Flabby A wine that lacks structure, or is heavy to
the taste, lacks acidity.
Full-Bodied Wine high in alcohol and extract, generally
speaking, fills the mouth, powerful.
Lean Generally describes wines that are slim,
lacking of generosity or thin.
Oaky A desirable flavor imparted to wine if done in
moderation. Most wines are aged in oak barrels one to three years, thereby receiving this toasty oak characteristic. However, if a weak wine is left in contact too long with an oak barrel it will tend to be overpowered with an oaky taste.
Tannin Tannins are extracted from the grape skins
and stems and are necessary for a well- balanced red wine. Tannins are easily identified in wine tasting as the drying sensation over the gums. Tannins generally fade as a wine ages.
Temperature: The most important element about
storage temperature is stability. If wine is kept in a stable
environment between 40°F (7°C) and 65°F (21°C), it will
remain sound. A small 1-2 degree temperature fluctuation
within a stable environment is acceptable. Larger
temperature fluctuations can affect the corks ability to
seal, allowing the wine toleak” from the bottle.
Humidity: The traditional view on humidity maintains
that wines should be stored on their sides in 50% - 80%
relative humidity to ensure cork moisture and proper fit in
the bottle. Contemporary wisdom suggests that the cork
surface is too small to be impacted by humidity. Further
the cork is sealed with a metal or wax capsule making
humidity penetration impossible. The concept of a humid
storage environment was derived from the necessity of
wineries to maintain moisture in their cellars to keep
wooden barrel staves swollen, preventing wine
evaporation and product loss. In fact, vineyards estimate
as much as a 10% product loss per year due to
evaporation while wine is aging in the wooden barrels.
Humidity, however, was not intended for the modern
home cellar where wine is stored in glass bottles with
sealed corks.
Light: UV rays are not only harmful to people, they are
damaging to wines - especially those in clear bottles.
Since oxygen molecules in wine absorb UV rays, wine
should never be stored in direct light for long periods of
time.
Vibration: Provided that sediment is left undistributed
and particles are not suspended, vibration in a storage
environment is not an issue. Wines can become flat or
tired when voids and vacuums are created inside the wine
bottle. In order to create voids and vacuums within a
liquid, aggressive motion or shaking of the wine bottle
would have to occur.
U-Line Wine Guide 3
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
The Right Temperature for Wine
Temperature Wines
Approximately 60°F (15°C) Red
50°F - 55°F (10°C -12°C) White
Approximately 45°F (7°C) Sparkling
Wine Captain® Models - A Touch of Elegance
In 1985 U-Line was the first North American appliance
manufacturer to develop a residential wine storage unit,
the Wine Captain®. Each U-Line Wine Captain® model is
designed to impress and inspire anyone with an interest in
wine by providing cellar conditions in stylish, undercounter
units. U-Line Wine Captain
temperatures, a 50% internal relative humidity and
protection from UV light rays. U-Line has the largest
product offering available, making storing, presenting,
and sharing your wine effortless and elegant.
®
models offer stable storage
U-Line Wine Guide 4
USER GUIDE
NOTE: After stocking, allow unit to stabilize product
temperatures for 24 hours.
3
1
2
4
5
Use These Racks For Larger Diameter Bottles
& Champange
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
Recommended Wine Storage
Specially designed horizontal wine racks properly position
the bottles so the wine remains in contact with the cork,
which ensures the cork does not become dry.
U-Line recommends arranging wine bottles as shown in
the illustrations below.
Racks 1 through 5:
Recommended Wine Storage 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Cleaning
EXTERIOR CLEANING
Vinyl Clad (Black or White)
Clean surfaces with a mild detergent and warm water
solution. Do not use solvent-based or abrasive cleaners.
Use a soft sponge and rinse with clean water. Wipe with a
soft, clean towel to prevent water spotting.
Clean any glass surfaces with a non-chlorine glass
cleaner.
Stainless Models
Stainless door panels, handles and frames can discolor
when exposed to chlorine gas, pool chemicals, saltwater
or cleaners with bleach.
Keep your stainless unit looking new by cleaning with a
good quality all-in-one stainless steel cleaner and polish
monthly. For best results use Claire
Polish and Cleaner. Comparable products are acceptable.
Frequent cleaning will remove surface contamination that
could lead to rust. Some installations may require cleaning
weekly.
®
Stainless Steel
If any surface discoloring or rusting appears, clean it
quickly with Bon-Ami
and a nonabrasive cloth. Always clean with the grain.
Always finish with Claire
Cleaner or comparable product to prevent further
problems.
Using abrasive pads such as Scotchbrite will cause the graining in the stainless steel to become blurred.
Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible.
Integrated Models
To clean integrated panels, use household cleaner per the
cabinet manufacturers recommendation.
INTERIOR CLEANING
Disconnect power to the unit.
Clean the interior and all removed components using a
mild nonabrasive detergent and warm water solution
applied with a soft sponge or non-abrasive cloth.
®
or Barkeepers Friend Cleanser®
®
Stainless Steel Polish and
Do not clean with steel wool pads.
Do not use stainless steel cleaners polishes on any glass surfaces.
Clean any glass surfaces with a non-chlorine glass
cleaner.
Do not use cleaners not specifically intended for stainless steel on stainless surfaces (this includes glass, tile and counter cleaners).
Rinse the interior using a soft sponge and clean water.
Do not use any solvent-based or abrasive
cleaners. These types of cleaners may transfer taste to
the interior products and damage or discolor the interior.
DEFROSTING
Under normal conditions this unit does not require manual
defrosting. Minor frost on the rear wall or visible through
the evaporator plate vents is normal and will melt during
each off cycle.
If there is excessive build-up of 1/4" (6 mm) or more,
manually defrost the unit.
Ensure the door is closing and sealing properly.
Cleaning 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
High ambient temperature and excessive humidity can
also produce frost.
CAUTION
!
DO NOT use an ice pick or other sharp
instrument to help speed up defrosting. These
instruments can puncture the inner lining or
damage the cooling unit. DO NOT use any type of
heater to defrost. Using a heater to speed up
defrosting can cause personal injury and
damage to the inner lining.
The drain pan was not designed to capture the
water created when manually defrosting. To
prevent water from overflowing the drain pan,
place towels or other absorbent materials over
the interior drain trough (under the evaporator)
before defrosting.
To defrost:
1. Disconnect power to the unit.
2. Remove all products from the interior.
3. Prop the door in an open position (2 in. [50 mm]
minimum).
4. Allow the frost to melt naturally.
5. After the frost melts completely clean the interior and
all removed components. (See INTERIOR CLEANING).
6. When the interior is dry, reconnect power and turn unit
on.
Cleaning 2
USER GUIDE
NOTICE
Condenser
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cleaning Condenser
INTERVAL - EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille
free of dust and lint, and clean the condenser when
necessary. Depending on environmental conditions, more
or less frequent cleaning may be necessary.
WARNING
!
Disconnect electric power to the unit before
cleaning the condenser.
WARNING
!
DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.
DO NOT use any type of cleaner on the
condenser unit.
1. Remove the grille.
2. Clean the condenser coil using a using a soft brush
with a “combing” action or vacuum cleaner.
3. Install the grille.
Cleaning Condenser 1
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Wine Rack Installation
To remove rack from the cabinet:
1. Remove any bottles stored on the rack.
2. Grasp the end of the rack and gently slide it out until it stops.
3. Press the left rack release lever down. At the same time, lift the matching right rack release lever up. Pull the rack out until it is free of the tracks and the cabinet.
Do not remove the track rails from the cabinet.
To insert rack in the cabinet:
1. Align the left and right rack channels with the tracks in the cabinet. Ensure an even track engagement on both sides by gently pushing the rack into the cabinet until it stops.
2. Before reloading the rack, ensure proper movement of the travel stops in the left and right track rails by pulling the rack out gently until it stops.
Wine Rack Installation 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Extended Non-Use
VACATION/HOLIDAY, PROLONGED SHUTDOWN
The following steps are recommended for periods of
extended non-use:
1. Remove all consumable content from the unit.
2. Disconnect the power cord from its outlet/socket and
leave it disconnected until the unit is returned to
service.
3. If ice is on the evaporator, allow ice to thaw naturally.
4. Clean and dry the interior of the unit. Ensure all water
has been removed from the unit.
5. The door must remain open to prevent formation of
mold and mildew. Open door a minimum of 2"
(50 mm) to provide the necessary ventilation.
WINTERIZATION
If the unit will be exposed to temperatures of 40°F (5°C)
or less, the steps above must be followed.
For questions regarding winterization, please
call U-Line at +1.800.779.2547.
CAUTION
!
Damage caused by freezing temperatures is not
covered by the warranty.
Extended Non-Use 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Troubleshooting
BEFORE CALLING FOR SERVICE
If you think your U-Line product is malfunctioning, read
the CONTROL OPERATION section to clearly understand
the function of the control.
If the problem persists, read the NORMAL OPERATING
SOUNDS and TROUBLESHOOTING GUIDE sections below
to help you quickly identify common problems and
possible causes and remedies. Most often, this will resolve
the problem without the need to call for service.
IF SERVICE IS REQUIRED
If you do not understand a troubleshooting remedy, or
your product needs service, contact U-Line Corporation
directly at +1.800.779.2547.
When you call, you will need your product Model and
Serial Numbers. This information appears on the Model
and Serial number plate located on the upper right or rear
wall of the interior of your product.
NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to
provide high thermal efficiency and maximum sound
reduction for its internal working components. Despite this
technology, your model may make sounds that are
unfamiliar.
Normal operating sounds may be more noticeable because
of the unit’s environment. Hard surfaces such as cabinets,
wood, vinyl or tiled floors and paneled walls have a
tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a
brief description of the normal operating sounds they
make. NOTE: Your product may not contain all the
components listed.
Evaporator: Refrigerant flowing through an evaporator
may sound like boiling liquid.
Condenser Fan: Air moving through a condenser may
be heard.
Automatic Defrost Drain Pan: Water may be heard
dripping or running into the drain pan when the unit is
in the defrost cycle.
TROUBLESHOOTING GUIDE
DANGER
!
ELECTROCUTION HAZARD. Never attempt to
repair or perform maintenance on the unit
before disconnecting the main electrical power.
Troubleshooting - What to check when problems occur:
Problem Possible Cause and Remedy
Interior Light Does Not Illuminate.
Light Remains on When Door Is Closed.
Unit Develops Frost on Internal Surfaces.
Unit Develops Condensation on External Surfaces.
Product Is Freezing.
If the unit is cooling, it may be in Sabbath mode.
Turn off light switch if equipped. Adjust light actuator bracket on bottom of
door.
Frost on the rear wall is normal and will melt during each off cycle.
If there is excessive build-up of 1/4" or more, manually defrost the unit.
Ensure the door is closing and sealing properly.
High ambient temperature and excessive humidity can also produce frost.
The unit is exposed to excessive humidity. Moisture will dissipate as humidity levels decrease.
Because product in contact with the rear wall may freeze, ensure no product is touching the rear wall.
Adjust the temperature to a warmer set point.
Compressor: The compressor makes a hum or pulsing
sound that may be heard when it operates.
Troubleshooting 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Problem Possible Cause and Remedy
Product Is Not Cold Enough.
Air temperature does not indicate product temperature. See CHECKING PRODUCT TEMPERATURE below.
Adjust the temperate to a cooler set point. Ensure unit is not located in excessive
ambient temperatures or in direct sunlight. Ensure the door is closing and sealing
properly. Ensure the interior light has not remained on
too long. Ensure nothing is blocking the front grille,
found at the bottom of the unit. Ensure the condenser coil is clean and free of
any dirt or lint build-up.
CHECKING PRODUCT TEMPERATURE
Causes which affect the internal temperatures of the cabinet include:
Temperature setting.
Ambient temperature where installed.
Installation in direct sunlight or near a heat source.
The number of door openings and the time the door is
open.
The time the internal light is illuminated. (This mainly
affects product on the top rack or shelf.)
Obstruction of front grille or condenser.
To check the actual product temperature in the unit:
1. Partially fill a plastic (nonbreakable) bottle with water.
2. Insert an accurate thermometer.
3. Tighten the bottle cap securely.
4. Place the bottle in the desired area for 24 hours.
5. Avoid opening the unit during the testing period.
6. After 24 hours, check the temperature of the water. If
required, adjust the temperature control in a small
increment (see CONTROL OPERATION).
Troubleshooting 2
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this U-Line product warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase. All service provided by U- Line under the above warranty must be performed by U-Line factory authorized service, unless otherwise specified by U-Line. Service provided during normal business hours.
Available Second Year Limited Warranty
Beyond the standard one year warranty outlined above, U-Line offers an extension of the one year warranty coverage for an additional second year from the date of purchase, free of charge. To take advantage of this second year warranty, you must register your product with U-Line within two months from the date of purchase at u-line.com providing proof of purchase.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or replace the following parts, labor not included, that prove to be defective in materials or workmanship: compressor, condenser, evaporator, drier, and all connecting tubing. All service provided by U-Line under the above warranty must be performed by U-Line factory authorized service, unless otherwise specified by U-Line. Service provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty states of the United States, the District of Columbia, or the ten provinces of Canada. The warranties do not cover any parts or labor to correct any defect caused by negligence, accident or improper use, maintenance, installation, service, repair, acts of God, fire, flood or other natural disasters. The product must be installed, operated, and maintained in accordance with the U-Line User Guide.
The remedies described above for each warranty are the only ones that U-Line will provide, either under these warranties or under any warranty arising by operation of law. U-Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty, whether express, implied, or statutory. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. These warranties give you specific legal rights, and you may also have other rights which vary from state to state.
Any warranty that may be implied in connection with your purchase or use of the product, including any warranty of merchantability or any warranty fit for a particular purpose is limited to the duration of these warranties, and only extends to five years in duration for the parts described in the section related to the five ye ar limited warranty above. Some states do not all ow limitations on how long an implied warranty lasts, so the above limitations may not apply to you.
The warranties only apply to the original purchaser and are non-transferable.
The second year and five year warranties cover products installed and used for normal residential or designated marine use only.
The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.
In-home instruction on how to use your product is not covered by these warranties.
Food, beverage, and medicine loss are not covered by these warranties.
If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.
Units purchased after use as floor displays no coverage is provided for cosmetic defects.
Signal issues related to Wi-Fi connectivity are not covered by these warranties.
, and/or certified reconditioned units, are covered by the limited one year warranty only and
For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 8900 N. 55th Street, Milwaukee, WI 53223 u-line.com • onlineservice@u-line.com • +1.800.779.2547
Copyright © 2014/2017 U-Line Corporation. All Rights Reserved. | Publication Number 30379 | 10/2017 Rev. L
Warranty 1
USER GUIDE
42350_B WIRING DIAGRAM
POWER CORD
ASSEMBLY
GROUND:
GREEN or GREEN W/ YELLOW
HOT:
BLACK (115v)
BROWN (220-240v)
NEUTRAL
HOT
RELAY
EMBRACO
COMPRESSOR
GREEN or
GREEN W/ YELLOW
GROUND:
115
VOLT
PLUG
220-240 VOLT
PLUG
OVERLOAD
NEUTRAL:
WHITE (115v)
DARK BLUE (220-240v)
(TO COMPRESSOR)
NEUTRAL:
WHITE (115v)
DARK BLUE (220-240v)
BLUE (115V)
LIGHT BLUE (220V-240V)
(TO COMPRESSOR)
1
10
CONTROL
BOARD
ZONE TEMP
FUSE
16
8
9
1
6
1
10
5
EVAP TEMP
L/T DOOR SWITCH
AMBIENT TEMP
R/B LIGHT
L/T LIGHT
COND FAN
EVAP TEMP
R/B DOOR SWITCH
CAP
PROGRAMING
TO DISPLAY
OPEN
ANTENNA
J9
J10
HOT (LIGHT BLUE)
OVERLOAD
EMBRACO COMPRESSOR
220-240 VOLT
RELAY
GREEN W/ YELLOW
GROUND:
NEUTRAL:
DARK BLUE
CAP.
BROWN BLUE
115 VOLT
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Wire Diagram
Wire Diagram 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Product Liability
Field service technicians are authorized to make an initial
assessment in the event of reported damages. If there are
any questions about the process involved, the technician
should call U-Line for further explanation.
While inspecting for defects or installation issues, photos
should be taken to document any damages or issues
found.
During the assessment, if the service technician is able to
find the source of the damage and it can be resolved by
replacement of a part, the servicer is authorized to
replace the part in question. The part that caused the
damage must be returned to U-Line in its entirety. The
part must be clearly labeled with the serial number of the
unit it was removed from, the date, and the servicer who
removed the part.
If the service technician determines the damage is the
result of installation issues (water connection/drain, etc.),
the consumer would be notified and the issues shall be
resolved at the direction of the consumer.
If damage is evident and the service technician is unable
to find the source, U-Line must be contacted at 1-800-
799-2547 for further direction
8900 N. 55th Street • Milwaukee, WI 53223
T: +1.414.354.0300 • F: +1.414.354.354.5696
Website: www.u-line.com
Right product. Right place.
Right temperature Since 1962.
Product Liability 1
USER GUIDE
14 30911 1 2 XXXX
Year
Month
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Warranty Claims
The following information defines the parameters for filing
a warranty claim:
Valid serial number needed
Valid model number needed
Narda (or equivalent) form or submitted online at
www.u-line.com
60 day submittal deadline from date of completed
service
Only one repair or unit per warranty claim
Refrigerant should be labeled and included on the labor
submittal
warranty status. We also accept the following
information to verify warranty status:
New Construction Occupancy Documents
•Closing Paperwork
Final Billing – Remodel
Noting all of the following on the warranty claim will be
considered proof of purchase, hard copy will not be
required:
Name of the selling Dealer
Date of purchase/installation
Order or Invoice number (if available)
Door and water level adjustments are covered 30 days
from install date.
Serial Number Requirements:
A typical serial number is shown above. The first two
digits of the first segment, 14, represents the production
year. The number between the dashes, 12, represents the
production month. In most cases, warranty status can be
verified by the production date information within the
serial number.
Description of document reviewed (i.e. store receipt,
closing paperwork, etc)
Parts and labor claims are paid separately. Indicate part
numbers and description for parts used in the warranty
repair. Include the purchase invoice and name of the parts
supplier used to procure the parts.
Alternatively, a Proof of Purchase (or equivalent) may
submitted with the warranty claim to document
Warranty Claims 1
Parts
26 27
2
25
23
14
29
9
18
8
1
17
7
16
U-1224WCINT-00B
Item Description U-Line P/N
1 Anti tip bracket w/screws 80-54221-00
2 Back panel 80-54204-00
3 Compressor electricals only 80-54149-00
4 Compressor w/electricals 80-54150-00
5 Condenser assembly 80-54264-00
6 Condenser fan w/screws 80-54014-00
7 Control Housing 80-54265-00
8 Display module 80-54252-00
9 Display rack, btm 80-54318-00
10 Door assembly w/ hinges 80-54263-00
11 Gasket, door 80-54213-00
12 Drain pan w/double sided tape 80-54217-00
13 Drier 80-54055-00
14 Evaporator assembly 80-54262-00
15 Grille w/screws 80-54267-00
16 Hinges(2) w/screws 80-54208-00
17 LED light strip and cover assy 80-54000-00
18 Leg Levelers (4) 80-54201-00
19 Magnet w/brkt and screws 80-54250-00
20 Main board (no case or wires) 80-54008-00
21 Packaging 80-54209-00
22 Power cord 80-54171-00
23 Rack Assembly 80-54269-00
24 Reed switch 80-54284-00
25 Slide Assembly 80-54219-00
26 Thermistor (1 pc) 80-54006-00
11
15
6
24
19
10
27 Thermistor cover and pin 80-54023-00
28 Wire harness, board 80-54251-00
29 Wood front w/screws 80-54283-00
12
5
13
4
3
20
Parts 1
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Ordering Replacement Parts
If you have a purchasing account, please utilize our
service website to order parts.
Orders may also be placed by Fax or phone. See our
contact information below:
www.U-LineService.com (with service login)
FAX Number: +1.414.354.5696
Phone Number: +1.800.779.2547
Use only genuine U-Line replacement parts. The
use of non-U-Line parts can reduce speed of ice
production, cause water to overflow from ice
maker mold, damage the unit, and void the
warranty.
Warranty parts will be shipped at no charge after U-Line
confirms warranty status. Please provide the model, serial
number, part number and part description. Some parts
will require color or voltage information.
If U-Line requires the return of original parts, we will
inform you when the parts order is taken. This
requirement will be noted on your packing list. A prepaid
shipping label will be included with the replacement part.
Please enclose a copy of the parts packing list and any
labor claims with your return. Please be sure the model
and serial numbers are legible on the paperwork. Tag the
part with the reported defect.
When ordering a non-warranty part, you will need an open
account and tax exemption on file at U-Line. Another
option would be to visit www.u-line.com to locate an
authorized parts distributor in your area.
Ordering Replacement Parts 1
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
System Diagnosis Guide
REFRIGERATION SYSTEM DIAGNOSIS GUIDE
System Condition
Normal Normal Slightly below
Overcharge Higher than
Undercharge Lower than
Partial Restriction
Complete Restriction
No Gas 0 PSIG to 25" Room
Suction Pressure
normal
normal
Somewhat lower than normal vacuum
In deep vacuum
Suction Line
room temperature
Very cold may frost heavily
Warm-near room temperature
Warm - near room temperature
Room temperature (cool)
temperature (cool)
Compressor Discharge
Very hot Very hot Warm Cold Normal
Slightly warm to hot
Hot Warm Warm Extremely cold
Very hot Top passes
Room temperature (cool)
Cool to hot Room
Condenser Capillary
Hot to warm Cool Cold Higher than
warm - Lower passes cool (near room temperature) due to liquid
Room temperature (cool)
temperature (cool)
Tube
Room temperature (cool) or colder
Room temperature (cool)
Room temperature (cool)
Evaporator Wattage
normal
Lower than near inlet - Outlet below room temperature
Extremely cold near inlet - Outlet below room temperature backing up
No refrigeration Lower than
No refrigeration Lower than
normal
Lower than
normal
normal
normal
System Diagnosis Guide 1
USER GUIDE
C
S
R
OVERLOAD PROTECTOR
STARTING RELAY
CAPACITOR
RELAY COVER
ULIN_0368_A
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Compressor Specifications
DANGER
!
Electrocution can cause death or serious injury.
Burns from hot or cold surfaces can cause
serious injury. Take precautions when servicing
this unit.
EMX20CLC
Disconnect the power source.
Do not stand in standing water when working
around electrical appliances.
Make sure the surfaces you touch are not hot or
frozen.
Do not touch a bare circuit board unless you are
wearing an anti-static wrist strap that is
grounded to an electrical ground or grounded
water pipe.
Refrigerant R600a
Voltage 115 - 127 VAC
Frequency 60 Hz
Run Cap 12μF/165 VAC
Start Winding 6.7 Ohm at 77°F
Run Winding 12.6 Ohm at 77°F
LRA 3.7 A
FLA 0.5 A
Starting Device 8EA14C
Overload 4TM142RFBYY-53
* All resistance readings are ±10%
Handle circuit boards carefully and avoid
touching components.
To measure the start winding resistance, measure across
the C and S pins.
To measure the run winding resistance, measure across
the C and R pins.
Also check S to R and you should get the sum of the run
and start windings.
To ensure the windings are not shorted, check the S and R
to ground.
Compressor Specifications 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE SERVICE
Troubleshooting - Extended
CAUTION
!
Never attempt to repair or perform maintenance
on the unit until the main electrical power has
been disconnected from the unit.
SPECIFIC ERRORS AND ISSUES
The technically advanced diagnostic capabilities of the
electronic controls utilized on the 1200 and 2200 series
units allows for easy and thorough troubleshooting.
Navigation of the control is the key and is explained in the
CONTROL OPERATION section of the manual, along with
control button layout, control function descriptions, a
service mode menu and service menu selection
explanations.
NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to
provide high thermal efficiency and maximum sound
reduction for its internal working components. Despite this
technology, your model may make sounds that are
unfamiliar.
Normal operating sounds may be more noticeable because
of the units environment. Hard surfaces such as cabinets,
wood, vinyl or tiled floors and paneled walls have a
tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a
brief description of the normal operating sounds they
make. NOTE: Your product may not contain all the
components listed.
Compressor: The compressor makes a hum or pulsing
sound that may be heard when it operates.
Verification of temperature and thermistor performance
can be identified by directly viewing thermistor readings in
the service mode.
Component failure issues can be identified through service
mode menu #19, “Component Testing.” Individual
components can be switched on and off to check for both
proper function of a specific component and also delivery
of supply voltage to the components through the relays
and DC outputs located on the relay/power board.
Included in this section are some diagnostic tips and of
course, if additional help is required please contact the
U-Line Corp, Customer Care Facility at +1.800.779.2547
for assistance.
Evaporator: Refrigerant flowing through an evaporator
may sound like boiling liquid.
Condenser Fan: Air moving through a condenser may
be heard.
Automatic Defrost Drain Pan: Water may be heard
dripping or running into the drain pan when the unit is
in the defrost cycle.
Solenoid Valves: An occasional clicking sound may be
heard as solenoid valves are operated.
Troubleshooting - Extended 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE SERVICE
TROUBLESHOOTING GUIDE
Concern Potential Causes Suggested Remedy
Not Cooling Compressor overheating Verify proper air flow through condenser. Is condenser clean?
Confirm condenser fan operation.
Confirm proper compressor operating voltage. Use #19, Component Testing in Service Mode.
Compressor not operating Confirm proper compressor operating voltage. Use #19, Component
Compressor operating - no cooling Refer to System Diagnosis Guide.
Evaporator fan not operating Use #19, Component Testing in Service Mode.
Frozen Product Control set too cold Adjust Set Point Temp accordingly.
Review logged error codes Refer to #14, Error Log in Service Mode.
Thermistor failure Check Error Log in Service Mode, OHM thermistor.
Frost Buildup Inside Unit
Display Not Working
Internal Lights Not Working
Noisy Refrigeration tubing touching cabinet Carefully reposition tubing.
Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry. Check distribution of
Evaporator fan not operating Use Relay Toggle, Component Testing in Service Mode.
Thermistor failure Check Error Log.
Unit placed in Sabbath mode? Press and hold for 5 seconds to check.
Display unplugged Verify that both ends of the display wiring are firmly connected.
Display wiring broken or damaged Perform continuity test of wiring and replace as needed.
Control Setting Unit set to Sabbath Mode. Press and hold for 5 seconds to check.
Door switch misaligned or defective Check the function of reed switch and door magnet adjustment.
Fan blade obstruction (wiring, foam insulation, packaging material)
Testing in Service Mode.
Test overload and relay, replace as needed.
product in unit.
Remove obstruction.
Troubleshooting - Extended 2
USER GUIDE
NOTICE
Check Voltage
At Wall Outlet
Verify Voltage At
Main Control
Voltage Input
Check Fuse F1 For Continuity
Replace
Reed Switch
Replace Main
Board
Replace
Fuse
Replace
Power Cord
Alert Customer
Of Power Failure
Is the Reed
Switch Operating
Properly?
Inspect
Customer UI
and Data Cable
Connect Test Display
Cycle Power And Check
For Operation
No Voltage
No Voltage
Voltage
Continuity
Operating
Not Operating
No Continuity
No
Yes
Voltage
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE SERVICE
MAIN CONTROL
The main control board is very robust and is rarely the
cause of system issues. It is important to fully diagnose
the board for any suspected failures before attempting to
remove the board for replacement or service. Follow the
guidelines below to fully test and diagnose the main
control.
Power Fault
If the unit does not (or seems to not) power on, follow the
flow chart below to help diagnose the issue. Before
beginning it is important to first verify the unit is not
simply set to sabbath mode.
Testing The Main Control
If the main control is suspected of being faulty, the
following procedure should be performed to verify main
control for functionality.
Relay & DC Outputs
One of the primary functions of the main control is to
operate the multiple relay and DC outputs during each
cycle. Verify proper operation of these relays using the
following procedure.
1. Enter “Relay Toggle” through the service menu.
Frequently toggling the compressor relay could
force the compressor into overload. The
compressor will automatically deactivate during
an overload and will remain deactivated until the
overload switch cools. This could take some
time. It is important to allow the compressor at
least 5 minutes off time between relay cycles.
2. Toggle the relay. Its related component should
activate / deactivate with the switching of the relay. If
it does not, test component.
Other Suspected Main Control Faults
If other components have been ruled out as being faulty
but the unit continues to have operating issues, it is most
likely due to a configuration error. Configuration errors
can be cleared by restoring the unit to its factory default
setting. Factory defaults may be restored through the
service menu.
CAUTION
!
Precautions must be taken while working with
live electrical equipment. Be sure to follow
proper safety procedures while performing tests
on live systems.
Troubleshooting - Extended 3
USER GUIDE
Magnet Close To Switch
(Door Closed)
(Switch Closed)
Magnet Away From Switch
(Door Open)
(Switch Open)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE SERVICE
REED SWITCH
A reed switch is used to monitor door state. When the
door is closed magnetic force pulls the reed to its contact
and closes the circuit which turns the light and display off.
When the door is open the reed pulls away from the
contact and opens the circuit. If the door is left open for
longer than 5 minutes, the switch will trigger an error code
and set an audible warning.
Troubleshooting - Extended 4
USER GUIDE
123 4567
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Control Operation - Service
UI BUTTON LAYOUT
1. Hidden Button
-Accesses Service Menu
-No LED directly above. All LEDs turn on with button activation except #7.
2.
Up Button
-Increases temperature
-Navigates through service menu
-LED activated with button activation.
3.
Down Button
-Decreases temperature
-Navigates through service menu
-LED activated with button activation
4.
Light Button
-Activates light for 3 hours on s elect models
-Used to select items in service menu
-LED activated with button activation
5.
Power Button
-Turns unit off/on
-LED activated with button activation (only turning unit off)
6. Clean Button
-Activates Clean Cycle on CLR models
-LED activated with button activation
LED
7.
-No button
Control Operation - Service 1
USER GUIDE
or
or
and
and
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
CONTROL FUNCTION QUICK GUIDE FUNCTION COMMAND DISPLAY/OPTIONS
ON/OFF Press and release Unit will immediately turn ON or OFF
Toggle lights
Adjust refrigerator temperature
View temperature in unit Push and release the together
Toggle between F/C Hold the for five seconds The display will change units.
Press and release to leave interior light on for 3 hours
Push and release
Glass door wine captains and beverage centers only.
When the “F” or “C in the display is flashi ng, push to adjust the set point temperature.
The display will flash and then toggle from set point to temperature in unit.
DOOR ALERT NOTIFICATION
When the door is left open for more than 5 minutes:
An audible tone will sound for several seconds every minute.
dr will appear in display.
Close door to silence alert and reset.
VIEWING ACTUAL TEMPERATURE
In viewing temperature in these modes any offsets are taken into account. This means that if you place a therm- istor in a known temperature, lets say ice water, it may not read the 32°F that you would assume. If the control offset was preset at -3°F while you placed the thermistor in an icebath, the actual thermistor reading when viewing actual temperature would read 35°F . In the unit this would cause the cabinet to push itself 3° cooler. To view pure thermistor readings you must go into the service menu and choose the correct option.
T o view the thermistor temperature, push and release the up and down keys. The display will show the corr ected refrigerator temperature.
When the degree symbol is flashing the unit will allow the use of the control for demonstrations. The unit can be left in this mode indefinitely.
SERVICE MODE
This mode has options available for service diagnostics. To enter the mode hold the hidden key for 10 seconds. The display will show “0. When in this mode use the up and down arrows to select the desired option. The LIGHT key is the ENTER key and will initiate the function. If changing a setting, you must press the LIGHT key again to retain the changed setting. T o exit the service mode scroll to option “0 and press the LIGHT key. After five minutes of not touching any keys the mode will also exit automatically.
SHOWROOM MODE
This mode is designed to show units in a display environ- ment. When in this mode the only functions will be the control and cabinet lights. The compressor, fans, etc. will not operate. To enter/exit this mode hold the light key and the power key for 5 seconds. The display will flash once and beep and the degree symbol will begin to flash.
Control Operation - Service 2
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
SERVICE MODE GUIDE
# Service Mode Menu Item
1 View thermistor #1 (no offsets) 2 View thermistor #2 (no offsets) 3 View thermistor #3 (no offsets) 4 View thermistor #4 (no offsets) 5 Adjust thermistor #1 offset 6 Adjust thermistor #2 offset 7 Adjust thermistor #3 offset 8 Adjust thermistor #4 offset
9 View thermistor #2 set point no offsets 10 View thermistor #3 set point no offsets 11 View thermistor #4 set point no offsets 12 Adjust defrost interval 3 to 24 hours 13 Adjust defrost duration 0 to 99 minutes 14 View error log 15 Clear error log 16 Adjust thermistor #1 differential 17 Adjust evaporator fan delay in minutes (start of cooling
cycle) 0 - 99 minutes
18 Adjust evaporator fan delay in minutes (after cooling
cycle stops) 0 - 99 minutes 19 Individual component toggle 20 Model number indicato r 21 Light all LED segments of display 22 View defrost cycles 23 View compressor run time 24 Activate defrost/harvest 25 Restore factory defaults 26 View software version - main board 27 View software version - user interface 28 Login period 29 Factory test mode
0Exit service mode
NAVIGATE SERVICE MODE
SERVICE MODE GUIDE
1. THERMISTOR 1 — ZONE
This shows the pure thermistor reading with no offsets taken into account.
2. THERMISTOR 2 — EVAPORATOR
This shows the pure thermistor reading with no offsets taken into account.
3. Does not apply to this model.
4. Does not apply to this model.
5. THERMISTOR 1 — ZONE OFFSET
(DO NOT MAKE AN ADJUSTMENT TO THIS WITHOUT CONTACTING TECH LINE: 800-779- 2547)
This calibration is only to be used if actual
temperature at thermistor #1 is off from set point.
By adjusting the offset higher we can force the unit to drive the temperature down below the set point. (example: adjusting from 0 to +2 will drop the unit temperature 2 degrees)
6. THERMISTOR 2 — EVAPORATOR OFFSET
(DO NOT MAKE AN ADJUSTMENT TO THIS WITHOUT CONTACTING TECH LINE: 800-779- 2547)
7. Does not apply to this model.
8. Does not apply to this model.
9. THERMISTOR 2 — SET POINT MINUS
OFFSET
This shows the thermistor reading with offsets taken into account.
10. Does not apply to this model.
11. Does not apply to this model.
12. ADJUST DEFROST INTERVAL — 3 TO 24
HOURS
This will adjust the interval between defrosts from 3 to 24 hours. Adjusting from the factory settings may cause undesired temperature in the refrigerator section.
Use up or down arrows to scroll through the menu. Use the light bulb key to enter or exit menu. If values
have been change d, they will be saved when exiting.
13. ADJUST DEFROST DURATION — 0 TO 99
MINUTES
The length of the defrost can be adjusted 0 to 99 minutes long. The other defrost parameters still apply. Lengthening a defrost may cause higher than normal temperatures in the refrigerator section.
Control Operation - Service 3
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
14. VIEW ERROR LOG
A list of the errors in the order they occurred will scroll once on the display. All errors are logged in memory. Only door error is displayed on the display and has an audible signal.
E0:
Door 1 (upper) open.
E1: Thermistor 1 open. E2: Thermistor 2 open. E3: Thermistor 3 open. E4: Thermistor 4 open (Does not apply to this
model).
E5: Thermistor 1 shorted. E6: Thermistor 2 shorted. E7: Thermistor 3 shorted. E8: Thermistor 4 shorted (Does not apply to this
model).
E9: Door 2 (lower) open. P1: Pump Circuit open (Does not apply to this
model).
15. CLEAR ERROR LOG
To clear errors, press and hold
(5 seconds)
when CLR is flashing.
16. THERMISTOR — 1 DIFFERENTIAL
This number should not be adjusted.
17. Does not apply to this model.
18. Does not apply to this model.
21. LIGHT ALL LED SEGMENTS
This will illuminate all the LEDs on the display to ensure they work properly.
22. VIEW DEFROST CYCLES
Displays the number of defrosts that have occurred in the past 24 hours.
23. VIEW COMPRESSOR RUNTIME
This will show the number of minutes the compressor has run in the prior cycle (or current cycle if the compressor was running when service mode was entered).
24. ACTIVATE DEFROST/HARVEST
Turns on the hot gas bypass valve allowing hot gas to circulate through the evaporator causing frost to melt.
25. RESTORE FACTORY DEFAULTS
Will restore all adjustable functions to their factory settings.
26. SOFTWARE VERSION — MAIN BOARD
Displays software version of the main control board.
19. INDIVIDUAL COMPONENT TOGGLE
Display # Relay/Output
0 Exit 2 Relay 2 3 Relay 3 4 Relay 4 5 Relay 5 6 Relay 6
7 Relay 7 8 DC Output 1
9 DC Output 2 10 DC Output 3 11 DC Output 4 12 DC Output 5
SEE RELAY/OUTPUT CHART
20. MODEL NUMBER INDICATOR
Displays the two-digit model number of the specific unit. See model list table.
27. SOFTWARE VERSION —
USER INTERFACE
Displays software version of the user interface.
28. LOG IN PERIOD
Factory use only - do not adjust.
29. FACTORY TEST MODE
Should be 0.
0. EXIT SERVICE MODE
Control Operation - Service 4
USER GUIDE
or
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
MODEL LIST
1000 MODEL
1215R 07 2218R 05 2245R 55 1215WC 12 2218RGL 04 2245DC 54 1224BEV 13 2218WC 06 2245WC 56 1224DWR 08 2224BEV 00 2260DC 50 1224R 14 2224FZR 11 2260FZR 57 1224RF 09 2224R 02 2260R 52 1224RSOD 10 2224RGL 01 2260RDC 51 1224WC 15 2224WC 03 2260WC 53 CLR1215 18 2224ZWC 59 2260ZWC 58 CO1224F 19 ADA24R 17
INDICATOR
2000 (120V) MODEL
INDICATOR
2000 (230V) MODEL
INDICATOR
PROGRAMMING THE UNIT TO CORRECT MODEL NUMBER
1. Disconnect the unit from power source.
2. Push and hold the U-Line button.
3. While still holding the U-Line button, plug the
unit into the appropriate power source.
4. When the flashing digits appear (3-5 seconds), use the up and down arrow buttons to select the
appropriate model number*.
*(See Above “Model List”)
5. Press the light bulb button once.
6. The display will blink, and then will appear as the
programmed display.
Control Operation - Service 5
USER GUIDE
Name Relay 2 Relay 3 Relay 4 Relay 5 Relay 6 Relay 7
p
p
p
p
p
1215R N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
1215WC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
124BEV N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
1224DWR
N/A N/A N/A N/A Compressor Top Light Evaporator Fan Condenser Fan N/A Bottom Light
1224R N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
1224RF N/A N/A Pan Heater Hot Gas Valve N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
1224RSOD N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
1224WC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
ADA24R N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
CLR1215 N/A Pump Water Valve Hot Gas Valve
Compressor Light N/A N/A N/A N/A
CO1224F Ice Maker 2 Ice Maker 1 Pan Heater Hot Gas Valve N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2218R N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2218RGL N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2218WC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2224BEV N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2224R N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2224RGL N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2224WC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2224ZWC N/A N/A vl2 vl1 N/A Compressor Top Light N/A Condenser Fan N/A Bottom Light
2245R N/A Hot Gas Valve N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2245RDC N/A Hot Gas Valve N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2245WC N/A Hot Gas Valve N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2260DC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2260R N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2260RDC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2260WC N/A N/A N/A N/A N/A Compressor Light Evaporator Fan Condenser Fan N/A N/A
2260ZWC N/A N/A vl2 vl1 N/A Compressor Top Light N/A Condenser Fan N/A Bottom Light
5HOD\2XWSXW&KDUW
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
ut 5
DC
Out
ut 4
DC
Out
ut 3
DC
Out
ut 2
DC
Out
ut 1
DC
Out
Condenser
Fan
Mullion
Heater
Control Operation - Service 6
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Thermistors
Thermistors are used for various temperature readings.
Thermistors provide reliable temperature readings using a
resistance which varies based on surrounding
temperatures. If a faulty thermistor is suspected it may
be tested using an accurate ohmmeter.
Both thermistors in the unit are identical. If a thermistor is
suspected of being defective, the resistance can be
verified. Place the thermistor in an ice water bath, the
resistance should read 16.1k OHMs +/-5% on your meter.
Thermistor connections must be kept clean. A thermistor
connection that has become corroded can cause
resistance values from the thermistor to change as they
pass through a dirty connection to the board.
It is for that reason that we apply dielectric grease to all of
our thermistor connections. Dielectric grease will help to
keep thermistor connections clean and dry.
If you change a thermistor in the unit please re-apply
dielectric grease to the connection. If you encounter a
dirty thermistor connection, you should replace the
thermistor and the thermistor harness.
Thermistor error information can be found in the Control
Operations - Service section.
This unit has two thermistors.
Thermistor one (Zone):
Located along the right hand side wall. It is used to
maintain the operating temperature within that zone.
Thermistor two (Evaporator):
Located on the evaporator. It is used for defrost.
THERMISTOR FAILURE
Zone Thermistor
1000 Series Self Preservation Mode:
The unit will cycle on for 10 minutes then off for 40
minutes.
Evaporator Thermistor
If the evaporator thermistor fails, the unit will rely on a
preset defrost timer during defrost cycles. The unit will
otherwise operate normally. Refer to defrost section.
Thermistor Resistance Data
Temp (F) Temp (C)
-40 -40 169157
-31 -35 121795
-22 -30 88766
-13 -25 65333
-4 -20 48614
5-15 36503
14 -10 27681
23 -5 21166
32 0 16330
41 5 12696
50 10 9951
59 15 7855
68 20 6246
77 25 5000
86 30 4029
95 35 3266
104 40 2665
113 45 2186
122 50 1803
131 55 1495
140 60 1247
149 65 1044
158 70 879
167 75 743
176 80 631
* (+/-5%)
Nominal Resistance
(OHMS)*
If the zone thermistor in the unit fails, the unit will
continue to cool in a backup mode (Self Preservation
Mode) to preserve the integrity of the contents. The unit
will otherwise operate normally.
Thermistor 1
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Defrost
The models below have automatic or frost free design and do not require manual defrosting under normal conditions.
Defrost Settings
Base Model Variant(s) Compressor Run Time
1224 RF 12 45 15 (-9)
1215/1224/2218/2245/
2224/2260
1215/1224/2218/2245/
2224/2260
CO29 F 12 18 n/a
CO1224 F 12 18 45 (7)
1224FZR Freezer Mode 6 45 42(6)
1224FZR Refrigerator Mode 12 45 42(6)
WC, ZWC 12 45 45 (7)
R, RSOD, RDC,
BEV, DC, DWR, RGL
Between Defrost (Hours)
12 45 42 (6)
Duration in Minutes
(Maximum)
Stop Temperature
°F (°C)
The defrost settings for 3000 series models are determined by zone.
Defrost Settings by Zone (3000 Series)
Zones Compressor Run Time
Between Defrost (Hours)
Beverage/Drinks 12 5 60 42 (6)
Market/Fresh 12 5 60 42 (6)
Root/Root Cellar 12 5 60 45 (7)
Pantry 12 5 60 42 (6)
White Wine 12 5 60 45 (7)
Red Wine 12 5 60 45 (7)
Sparkling Wine 12 5 60 45 (7)
Polar 6 5 20 42 (6)
Deli 12 5 60 42 (6)
Duration in Minutes
(Minimum)
Duration in Minutes
(Maximum)
Stop Temperature
°F (°C)
Defrost 1
Loading...