Tweco C-35A User Manual

Page 1
C-35A
®
CUTSKILL
PLASMA CUTTING SYSTEM
Operator Manual
Operating Features:
PLASMA
Page 2
Page 3
WARNINGS
Read and understand this entire Manual and your employer’s safety practices before installing, operating, or servicing the equipment.
While the information contained in this Manual represents the Manufacturer's best judgement, the Manufacturer assumes no liability for its use.
Plasma Cutting Power Supply CutSkill
®
SL60™ 1Torch™ Operation Manual Number 0-4678
Covered under U.S. Patents.
Published by: Thermadyne Corporation 82 Benning Street West Lebanon, New Hampshire, USA 03784 (603) 298-5711
www.thermal-dynamics.com
©Copyright 2005, 2006, 2007 by Thermal Dynamics Corporation
All rights reserved.
Reproduction of this work, in whole or in part, without written permission of the publisher is prohibited.
The publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused by any error or omission in this Manual, whether such error results from negligence, accident, or any other cause.
Printed in the United States of America
Publication Date: March 26, 2007
Record the following information for Warranty purposes:
Where Purchased:____________________________________
Purchase Date:_______________________________________
Power Supply Serial #:________________________________
Torch Serial #:________________________________________
Page 4
Page 5
TABLE OF CONTENTS
SECTION 1:
GENERAL INFORMA TION ................................................................................................ 1-1
1.01 Notes, Cautions and Warnings ...................................................................... 1-1
1.02 Important Safety Precautions....................................................................... 1-1
1.03 Publications .................................................................................................. 1-2
1.04 Declaration of Conformity ............................................................................. 1-4
1.05 Statement of Warranty .................................................................................. 1-5
SECTION 2:
INTRODUCTION ............................................................................................................... 2-1
2.01 Overview ...................................................................................................... 2-1
2.02 General Specifications.................................................................................. 2-1
2.03 Features ....................................................................................................... 2-1
2.04 Torch Specifications ..................................................................................... 2-2
2.05 System Contents.......................................................................................... 2-2
2.06 T ransporting Methods ................................................................................... 2-2
SECTION 3:
INSTALLATION.................................................................................................................. 3-1
3.01 Site Selection ............................................................................................... 3-1
3.02 Electrical Input Connections ......................................................................... 3-1
3.03 Compressed Air Connection ......................................................................... 3-1
SECTION 4:
OPERATION...................................................................................................................... 4-1
4.01 Front Control Panel ....................................................................................... 4-1
4.02 Preparations For Operating ........................................................................... 4-2
SECTION 5:
SERVICE .......................................................................................................................... 5-1
5.01 General Maintenance .................................................................................... 5-1
5.02 Basic T roubleshooting Guide......................................................................... 5-1
5.03 Contact information ...................................................................................... 5-3
Appendix 1: Operating Sequence, Block Diagram .....................................................................A-1
Appendix 2: Torch Connection ................................................................................................... A-2
Appendix 3: Microchip Pin-Out .................................................................................................. A-3
Appendix 4: Replacement Hand Torch Parts List ....................................................................... A-4
Appendix 5: System Schematic Rev A ..................................................................................... A-6
Appendix 6: System Schematic Rev AB ............................................................ Inside Rear Cover
Global Customer Service Contact Information ............................... Inside Rear Cover
Page 6
Page 7
SECTION 1:
GENERAL INFORMATION
1.01 Notes, Cautions and Warnings
Throughout this manual, notes, cautions, and warnings are used to highlight important information. These high­lights are categorized as follows:
NOTE
An operation, procedure, or background informa­tion which requires additional emphasis or is help­ful in efficient operation of the system.
CAUTION
A procedure which, if not properly followed, may cause damage to the equipment.
WARNING
A procedure which, if not properly followed, may cause injury to the operator or others in the oper­ating area.
1.02 Important Safety Precautions
WARNINGS
OPERATION AND MAINTENANCE OF PLASMA ARC EQUIPMENT CAN BE DAN­GEROUS AND HAZARDOUS TO YOUR HEALTH.
Plasma arc cutting produces intense electric and magnetic emissions that may interfere with the proper function of cardiac pacemakers, hearing aids, or other electronic health equipment. Persons who work near plasma arc cutting applications should consult their medical health professional and the manufacturer of the health equipment to determine whether a hazard exists.
To prevent possible injury, read, understand and follow all warnings, safety precautions and instruc­tions before using the equipment. Call 1-603-298­5711 or your local distributor if you have any ques­tions.
GASES AND FUMES
Gases and fumes produced during the plasma cutting process can be dangerous and hazardous to your health.
• Keep all fumes and gases from the breathing area. Keep your head out of the welding fume plume.
• Use an air-supplied respirator if ventilation is not adequate to remove all fumes and gases.
• The kinds of fumes and gases from the plasma arc depend on the kind of metal being used, coatings on the metal, and the different processes. You must be very careful when cutting or welding any met­als which may contain one or more of the follow­ing:
Antimony Chromium Mercury Arsenic Cobalt Nickel Barium Copper Selenium Beryllium Lead Silver Cadmium Manganese Vanadium
• Always read the Material Safety Data Sheets (MSDS) that should be supplied with the material you are using. These MSDSs will give you the in­formation regarding the kind and amount of fumes and gases that may be dangerous to your health.
• For information on how to test for fumes and gases in your workplace, refer to item 1 in Subsection 1.03, Publications in this manual.
• Use special equipment, such as water or down draft cutting tables, to capture fumes and gases.
• Do not use the plasma torch in an area where com­bustible or explosive gases or materials are located.
• Phosgene, a toxic gas, is generated from the vapors of chlorinated solvents and cleansers. Remove all sources of these vapors.
• This product, when used for welding or cutting, pro­duces fumes or gases which contain chemicals known to the State of California to cause birth de­fects and, in some cases, cancer. (California Health & Safety Code Sec. 25249.5 et seq.)
ELECTRIC SHOCK
Electric Shock can injure or kill. The plasma arc process uses and produces high voltage electrical energy. This electric energy can cause severe or fatal shock to the op­erator or others in the workplace.
• Never touch any parts that are electrically “live” or “hot.”
Manual No. 0-4678 1-1 GENERAL INFORMATION
Page 8
• Wear dry gloves and clothing. Insulate yourself from the work piece or other parts of the welding circuit.
• Repair or replace all worn or damaged parts.
• Extra care must be taken when the workplace is moist or damp.
• Install and maintain equipment according to NEC code, refer to item 9 in Subsection 1.03, Publications.
• Disconnect power source before performing any ser­vice or repairs.
• Read and follow all the instructions in the Operat­ing Manual.
FIRE AND EXPLOSION
Fire and explosion can be caused by hot slag, sparks, or the plasma arc.
• Be sure there is no combustible or flammable mate­rial in the workplace. Any material that cannot be removed must be protected.
• Ventilate all flammable or explosive vapors from the workplace.
• Do not cut or weld on containers that may have held combustibles.
• Provide a fire watch when working in an area where fire hazards may exist.
• Hydrogen gas may be formed and trapped under aluminum workpieces when they are cut underwa­ter or while using a water table. DO NOT cut alu- minum alloys underwater or on a water table un­less the hydrogen gas can be eliminated or dissipated. Trapped hydrogen gas that is ignited will cause an explosion.
NOISE
Noise can cause permanent hearing loss. Plasma arc pro­cesses can cause noise levels to exceed safe limits. You must protect your ears from loud noise to prevent per­manent loss of hearing.
• To protect your hearing from loud noise, wear pro­tective ear plugs and/or ear muffs. Protect others in the workplace.
• Noise levels should be measured to be sure the deci­bels (sound) do not exceed safe levels.
• For information on how to test for noise, see item 1 in Subsection 1.03, Publications, in this manual.
PLASMA ARC RAYS
Plasma Arc Rays can injure your eyes and burn your skin. The plasma arc process produces very bright ultra violet and infra red light. These arc rays will damage your eyes and burn your skin if you are not properly protected.
• To protect your eyes, always wear a welding hel­met or shield. Also always wear safety glasses with side shields, goggles or other protective eye wear.
• Wear welding gloves and suitable clothing to pro­tect your skin from the arc rays and sparks.
• Keep helmet and safety glasses in good condition. Replace lenses when cracked, chipped or dirty.
• Protect others in the work area from the arc rays. Use protective booths, screens or shields.
• Use the shade of lens as suggested in the following per ANSI/ASC Z49.1:
Minimum Protective Suggested
Arc Current Shade No. Shade No.
Less Than 300* 8 9
300 - 400* 9 12
400 - 800* 10 14
* These values apply where the actual arc is clearly seen. Experience has shown that lighter filters may be used when the arc is hidden by the workpiece.
1.03 Publications
Refer to the following standards or their latest revisions for more information:
1. OSHA, SAFETY AND HEALTH STANDARDS, 29CFR 1910, obtainable from the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402
2. ANSI Standard Z49.1, SAFETY IN WELDING AND CUTTING, obtainable from the American Welding So­ciety, 550 N.W. LeJeune Rd, Miami, FL 33126
3. NIOSH, SAFETY AND HEALTH IN ARC WELDING AND GAS WELDING AND CUTTING, obtainable from the Superintendent of Documents, U.S. Government Printing Office, Washington, D.C. 20402
4. ANSI Standard Z87.1, SAFE PRACTICES FOR OCCU­PATION AND EDUCATIONAL EYE AND FACE PRO­TECTION, obtainable from American National Stan­dards Institute, 1430 Broadway, New York, NY 10018
5. ANSI Standard Z41.1, STANDARD FOR MEN’S SAFETY-TOE FOOTWEAR, obtainable from the Ameri­can National Standards Institute, 1430 Broadway, New York, NY 10018
GENERAL INFORMATION 1-2 Manual No. 0-4678
Page 9
6. ANSI Standard Z49.2, FIRE PREVENTION IN THE USE OF CUTTING AND WELDING PROCESSES, ob­tainable from American National Standards Institute, 1430 Broadway, New York, NY 10018
7. AWS Standard A6.0, WELDING AND CUTTING CONTAINERS WHICH HAVE HELD COMBUS­TIBLES, obtainable from American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126
8. NFPA Standard 51, OXYGEN-FUEL GAS SYSTEMS FOR WELDING, CUTTING AND ALLIED PRO­CESSES, obtainable from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
9. NFPA Standard 70, NATIONAL ELECTRICAL CODE, obtainable from the National Fire Protection Associa­tion, Batterymarch Park, Quincy, MA 02269
10. NFPA Standard 51B, CUTTING AND WELDING PRO­CESSES, obtainable from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269
11. CGA Pamphlet P-1, SAFE HANDLING OF COM­PRESSED GASES IN CYLINDERS, obtainable from the Compressed Gas Association, 1235 Jefferson Davis Highway, Suite 501, Arlington, VA 22202
12. CSA Standard W117.2, CODE FOR SAFETY IN WELD­ING AND CUTTING, obtainable from the Canadian Standards Association, Standards Sales, 178 Rexdale Boulevard, Rexdale, Ontario, Canada M9W 1R3
13. NWSA booklet, WELDING SAFETY BIBLIOGRAPHY obtainable from the National Welding Supply Associa­tion, 1900 Arch Street, Philadelphia, PA 19103
14. American Welding Society Standard AWSF4.1, RECOM­MENDED SAFE PRACTICES FOR THE PREPARA­TION FOR WELDING AND CUTTING OF CONTAIN­ERS AND PIPING THAT HAVE HELD HAZARDOUS SUBSTANCES, obtainable from the American Welding Society, 550 N.W. LeJeune Rd, Miami, FL 33126
15. ANSI Standard Z88.2, PRACTICE FOR RESPIRATORY PROTECTION, obtainable from American National Standards Institute, 1430 Broadway, New York, NY 10018
Manual No. 0-4678 1-3 GENERAL INFORMATION
Page 10
1.04 Declaration of Conformity
Manufacturer: Thermal Dynamics Corporation Address: 82 Benning Street
West Lebanon, New Hampshire 03784 USA
The equipment described in this manual conforms to all applicable aspects and regulations of the ‘Low Voltage Directive’ (European Council Directive 73/23/EEC as amended by Council Directive 93/68/EEC) and to the National legislation for the enforcement of this Directive.
The equipment described in this manual conforms to all applicable aspects and regulations of the "EMC Directive" (European Council Directive 89/336/EEC) and to the National legislation for the enforcement of this Directive.
Serial numbers are unique with each individual piece of equipment and details description, parts used to manufacture a unit and date of manufacture.
National Standard and Technical Specifications
The product is designed and manufactured to a number of standards and technical requirements. Among them are:
* CSA (Canadian Standards Association) standard C22.2 number 60 for Arc welding equipment.
* UL (Underwriters Laboratory) rating 94VO flammability testing for all printed-circuit boards used.
* CENELEC EN50199 EMC Product Standard for Arc Welding Equipment.
* ISO/IEC 60974-1 (BS 638-PT10) (EN 60 974-1) (EN50192) (EN50078) applicable to plasma cutting equipment and
associated accessories.
* For environments with increased hazard of electrical shock, Power Supplies bearing the S mark conform to EN50192
when used in conjunction with hand torches with exposed cutting tips, if equipped with properly installed standoff guides.
* Extensive product design verification is conducted at the manufacturing facility as part of the routine design and
manufacturing process. This is to ensure the product is safe, when used according to instructions in this manual and related industry standards, and performs as specified. Rigorous testing is incorporated into the manufacturing process to ensure the manufactured product meets or exceeds all design specifications.
Thermal Dynamics has been manufacturing products for more than 30 years, and will continue to achieve excellence in our area of manufacture.
Manufacturers responsible representative: Steve Ward
Operations Director Thermadyne Europe Europa Building Chorley N Industrial Park Chorley, Lancashire, England PR6 7BX
GENERAL INFORMATION 1-4 Manual No. 0-4678
Page 11
1.05 Statement of Warranty
LIMITED WARRANTY: Subject to the terms and conditions established below, Thermadyne® Corporation warrants to the original retail purchaser that new Thermadyne CutSkill Series plasma cutting systems sold after the effective date of this warranty are free of defects in material and workmanship. Should any failure to conform to this warranty appear within the applicable period stated below, Thermadyne Corporation shall, upon notification thereof and substantiation that the product has been stored operated and maintained in accordance with Thermadyne’s specifications, instructions, recommendations and recognized industry practice, correct such defects by suitable repair or replacement.
This warranty is exclusive and in lieu of any warranty of merchantability or fitness for a particular purpose.
Thermadyne will repair or replace, at its discretion, any warranted parts or components that fail due to defects in material or workmanship within the time periods set out below. Thermadyne Corporation must be notified within 30 days of any failure, at which time Thermadyne Corporation will provide instructions on the warranty procedures to be implemented.
Thermadyne Corporation will honor warranty claims submitted within the warranty periods listed below. All warranty periods begin on the date of sale of the product to the original retail customer or 1 year after sale to an authorized Thermadyne Distributor.
LIMITED WARRANTY PERIOD
Product
Power Supply Componants
(Parts and Labor)
Torch and Leads
(Parts and Labo r) C-20A 1 Year 1 Year C-35A 1 Year 1 Year C-70A 1 Year 1 Year
C-100A 1 Year 1 Year
This warranty does not apply to:
1. Consumable Parts, such as tips, electrodes, shield cups, o - rings, starter cartridges, gas distributors, fuses, filters.
2. Equipment that has been modified by an unauthorized party, improperly installed, improperly operated or misused based upon industry standards.
In the event of a claim under this warranty, the remedies shall be, at the discretion of Thermadyne Corporation:
1. Repair of the defective product.
2. Replacement of the defective product.
3. Reimbursement of reasonable costs of repair when authorized in advance by Thermadyne.
4. Payment of credit up to the purchase price less reasonable depreciation based on actual use.
These remedies may be authorized by Thermadyne and are FOB West Lebanon, NH or an authorized Thermadyne service station. Product returned for service is at the owner’s expense and no reimbursement of travel or transportation is authorized.
LIMITATION OF LIABILITY: Thermadyne Corporation shall not under any circumstances be liable for special or consequential damages such as, but not limited to, damage or loss of purchased or replacement goods or claims of customer of distributors (hereinafter “Purchaser”) for service interruption. The remedies of the Purchaser set forth herein are exclusive and the liability of Thermadyne with respect to any contract, or anything done in connection therewith such as the performance or breach thereof, or from the manufacture, sale, delivery, resale, or use of the goods covered by or furnished by Thermadyne whether arising out of contract, negligence, strict tort, or under any warranty, or otherwise, shall not, except as expressly provided herein, exceed the price of the goods upon which liability is based.
This warranty becomes invalid if replacement parts or accessories are used which may impair the safety or performance of any Thermadyne product.
This warranty is invalid if the Thermadyne product is sold by non - authorized persons.
Effective January 25, 2005
Manual No. 0-4678 1-5 GENERAL INFORMATION
Page 12
This Page Left Blank
GENERAL INFORMATION 1-6 Manual No. 0-4678
Page 13
SECTION 2:
at Am bient Ai r Temperatures
at Am bient Ai r Temperatures
at Am bient Ai r Temperatures
s
CUT
5
INTRODUCTION
OFF
35A

2.01 Overview

Plasma is a gas which has been heated to an extremely high temperature and ionized so that it becomes elec­trically conductive. The plasma arc cutting process uses this plasma to transfer an electrical arc to the work­piece. The metal to be cut is melted by the heat of the arc and then blown away.

2.02 General Specifications

Sy st em Des c ript i ons C-35A
Max im um Output 35 Am ps Input V oltage & Phase Frequency 50/60Hz
Input P ower 7.4 kVA Current In put Fu s e 20 Am p s No Load Voltage 330V Load V olt age 94V Output Current 15-35 Am ps Post Flow Time 10 Seconds
Operat ing A i r P res s ure
Maximum Air Pressure
Air Flow
Sy s t em *Dut y Cy c le ratings
of 40° C / 104° F. Sy s t em *Dut y Cy c le ratings
of 40° C / 104° F. Sy s t em *Dut y Cy c le ratings
of 40° C / 104° F. Maximum Cutting Capacity @ 35A
Dimension (W x D x H)
Net Wei ght
230V , Single P has e
75 ps i (5. 2 bar)(.52MPa) 125 ps i (8. 6 bar)(.86MPa)
400 s cfh
6.6 scfm (188.7 lpm)
35% @ 35A m ps
60% @ 27A m ps
100% @ 20A mp
1/2" (12mm )
8.3"x 20"x 14. 8" (210 mm x 510 mm x 350 mm ) 44 lbs. (20kg )
CUT
27A
CUT
20A
35% (3.5 min)
60% (6 min)
OFF
100% (10 min)
NOTE:
*Duty Cycle is the percentage of time the sys­tem can be operated without overheating. Duty cycle is reduced if primary input voltage (AC) is low or the DC voltage is higher than shown in previous chart.

2.03 Features

• PORTABLE - Weighing just 44 lbs., (20 kg) it is easily moved from location to location.
• POWERFUL CUTTING PERFORMANCE ­Maximum cutting capacity is 1/2” (12mm).
• CUTS MOST METALS - Useful for most metals such as stainless steel, aluminum, mild steel, cop­per and alloys.
• NO HIGH FREQUENCY - Starts without high­frequency so it won’t interfere with controls or computers.
• MORE TORCH, LESS MONEY - The SL60™ 1T orch™ pr ovides state of the art technology and performance of more expensive torches.
Art # A-0450
Manual 0-4678 2-1 Introduction
Page 14

2.04 Torch Specifications

Torch Leads Length
20 fe et ( 6. 1 m )
Temperature
40° C
Straight Polarity
peak
SL60™ 1T orc h™ Rat i ng s f or C-35A
ITEMS
Description
Q'ty
Accessories &
Torch Electrodes
1
1
1
2
1-1635-1

2.05 System Contents

Torch Confi gurati on
Ambient
Torch Du ty Cyc l e
Maximum Current Volt age (V
)500V
Torc h Head at 75° t o Torch Handle
104° F
100% @ 60 A m ps @ 400 sc fh 60 Amps, DC,
Arc Striking Voltage 7kV Ty pe of Cooli ng
Parts-in-Place:
Gas Requ i re m en t:
Input Gas Pres s ure
Minimum Gas Flow
Plasma Power Supply Used With:
Ambient air and gas stream through torc h Built-in Switch in Torch Head Single Gas, Compressed Air Only
75 ps i ( 5.2 bar) (.52MPa) ­125 psi (8. 6 bar) (.86MP A)
400 s cfh / 6.6 sc fm (188.7 lpm)
C-35A
Power Source Model C-35A 1 Torch Set
Consumables
Input Power Cable F or Systems
Input Power Cable F or Systems 1-1635-4 (CE)
SL60™, wit h 20' leads (6.1m) 1 Air Regulator Work Cable Manual
Torc h Tips 3 Meter NEMA 10 AWG /
4.8 mm molded plug
2 Meter Cord With No Plug
2
with 6 - 50 P
3
1
1
If you have questions or concerns regarding your sys­tem, please contact:
Thermal Dynamics Technical Service Dept. Tel: 1-800-752-7622 (1-800-PLASMA2) Fax: 1-800-221-4401 e-mail address: tdc-tech@thermadyne.com

2.06 Transpor ting Methods

Lift unit with handle on top of case. Use handcart or similar device of adequate capacity for transporting.
WARNINGS
ELECTRIC SHOCK can kill. DO NOT TOUCH live electrical parts. Disconnect input power from supply before moving the power source.
F ALLING EQUIPMENT can cause serious per­sonal injury and equipment damage.
Introduction 2-2 Manual 0-4678
Page 15
SECTION 3:
Connect

3.03 Compressed Air Connection

INSTALLATION

3.01 Site Selection

• Place in a clean and dry area.
• Provide adequate ventilation and fresh air sup­ply.
• Ideal ambient temperature should not exceed 40°C / 104°F. Temperatures exceeding that may diminish cutting capacity or quality.
• The cutting machine must be placed on an even, firm surface so that it stands firmly.

3.02 Electrical Input Connections

• Input voltage is 230V ± 10%, 50/60 Hz single phase.
CAUTION
Check your power source for correct voltage be­fore plugging in or connecting the unit. The primary power source, fuse, and any extension cords used must conform to local electrical code and the recommended circuit protection and wir­ing requirements as specified in Section 2.0.
• An air compressor is requir ed and should be con­nected to rear panel of power source by air hose.
• Air pressure should be 75 psi (5.2 bar) (.52MPa) and air should be dry and clean.
• Air flow should be 400 scfh / 6.6 scfm (188.7 lpm) minimum.
Air Here
Input Power
Art # A-04485
DANGER
Do not cut in humid or wet surroundings.
• Before you maintain or replace torch parts, wait for the post flow air cycle (approximately 10 sec­onds), to stop, then turn the machine off.
• Always use original manufacturers parts. The use of aftermarket parts could result in shorter parts life and in unsatisfactory cutting results. Any war­ranty claims would be waived.
NOTE
Repairs must be done by skilled and qualified personnel only.
Manual 0-4678 3-1 Installation
Page 16
This Page Left Blank
Installation 3-2 Manual 0-4678
Page 17
SECTION 4:
Air Error Indicator
r h
n
A
0
A
OPERATION
B. Buttons
• Torch Switch Latch Button

4.01 Front Control Panel

Overheating Indicator
"On / Off" Switch
AC Power Indicator
Air V ents
Work Lead Connection
A. Indicator Lamp
• Power Indicator Lights when primary power switch is turned
on.
• TEMPERA TURE Indicator
35A
Art # A-04386
I
18
17
19
16
14
20
15
16
21
12
14
22
18
13
23
10
12
24
20
8
11
25
115VAC
10
O
230VAC
A
Torch Switch Latch Indicato
Torch Switc Latch Butto
Air Set Button
Current Control Knob
Torch Connection
For continuous cutting performance. Depress this button ( turn “On” ) while cutting with the torch. Release the torch trigger and the torch will continue to cut without depressing the torch trigger.
• Air Set Button
To adjust air pressure and to cool down heated torch.
Art # A-04503
Air will flow from gap next to shield cup.
C. Main Current Control Knob
T o adjust cutting current. T urning clockwise in­creases the cutting current and counter clock­wise decreases the cutting current.
Indicator is normally OFF. Indicator is ON when internal temperature exceeds normal limits.
20
25
3
15
• Air Error Indicator This indicator lights and is accompanied by an
intermittent audible tone when there is not
10
35
enough air pressure to operate the power sup­ply. Indicator is normally off.
NOTE
D. Primary Power Switch, ON / OFF
It is possible to have enough air pressure to op­erate the power supply but not enough air flow to operate the torch.
• Torch Switch Latch Indicator
rt # A-04387
The power switch is located on the front panel. Placing the primary power switch to the “ON” position energizes the power source and acti­vates the Power Indicator .
W ARNING
This indicator lights when the Torch Switch Latch Button has been pressed for continuous cutting.
When the power source is overloaded, the switch turns to the OFF position automatically. DO NOT TURN ON BY FORCE.
Manual 0-4678 4-1 Oper ation
Page 18

4.02 Preparations For Operating

Make a clean work cable
W A
Art # A-04389
3
D. Torch Operation
At the start of each operating session:
W ARNING
Disconnect primary power at the source before assembling or disassembling power supply, torch parts, or torch and leads assemblies.
A. Torch Parts Selection
Check the torch for proper assembly and appro­priate torch parts. The torch parts must correspond with the type of operation, and with the amperage output of this Power Supply (35 amps maximum). Use only genuine manufactured parts with this torch.
• Refer to Section 1 for necessary safety precau­tions.
Trigger
1
2
Trigger Release
3
4
Art # A-0338
Electrode 9-8215
Start Cartridge 9-8213
Tip 9-8207
Art # A-04388
Shield Cup 9-8218
B. Torch Connection
Check that the torch is properly connected.
C. Connect Work Cable
connection to the work­piece or cutting table
ork Cable
nd Clamp
Operation 4-2 Manual 0-4678
Page 19
E. Typical Cutting Speeds
Cutting speeds vary according to torch output, the type of material being cut, and operator skill. Speeds shown are typical for this cutting system using air plasma to cut mild steel, with output current at the highest setting and the torch used in the Drag mode or standoff height indicated.
Unit Standoff
C-35A Drag (10GA) 0. 135" ( 3mm ) 94.7 2367 75.7 1893 C-35A Drag (7GA) 0.179" (4. 5mm ) 57.0 1425 45.6 1140 C-35A 1/8" (3mm ) 1/ 4" (6m m) 36. 3 908 29.1 727 C-35A 1/8" (3mm ) 3/ 8" (10mm ) 15.3 383 12.3 307 C-35A 1/8" (3mm ) 1/ 2" (12mm ) 9. 7 242 7.7 193
Material
Thickness
Max im um Travel S peed
(ipm , mm/m)
Recomm ended Travel Speed
(imp , mm/m)
NOTE:
Drag or Drag mode refers to the torch tip being in contact with the work piece at all times.
Manual 0-4678 4-3 Oper ation
Page 20
This Page Left Blank
Operation 4-4 Manual 0-4678
Page 21
SECTION 5:
g
U i C
U w M
SERVICE

5.01 General Maintenance

1. Basic Tr oubleshooting Overview
This guide covers basic troubleshooting. It is helpful for solving many of the common problems that can arise with this system. If major complex subassemblies are faulty, the unit must be returned to an authorized service center for repair .
O-rings on the Torch require lubrication on a regular basis, depending on how frequently the torch shield cup is disconnected and re-connected. This will allow the O-rings to remain pliable and provide a proper seal. The O-rings will dry out, becoming hard and cracked, if the O-ring lubricant is not used on a regular basis. This can lead to potential performance prob­lems.
Remove and apply a very light film of O-ring lubricant (Catalog # 8-4025) to the O-rings on a weekly basis.
NOTE
DO NOT use other lubricants or grease on the torch
O-rings. They may not be designed to operate within high temperatures or may contain “unknown ele­ments” that may react with the atmosphere. This reaction can leave contaminants inside the torch. Either of these conditions can lead to inconsistent performance or poor parts life.
Art # A-04394
Follow all instructions as listed and complete each sec­tion in the order presented.
2. Common Symptoms
A. Primary power switch is ON, but power indicator
doesn’t light.
1. Improper electrical connection.
a. Check the input cable line & connection. b. Check input power that its turned on. c. Check the input power fuse.
2. System was overloaded.
a. Turn Primary Power Switch Off and then On
again.
3. Switch may be faulty.
a. Return to an authorized service center for re-
pair .
B. Primary power switch is on, but the cooling fan
does not work.
1. No power / incorrect power to fan or failed fan.
a. Return to an authorized service center for re-
pair .
pper Groove ith V ent Holes
ust Remain Open
pper O-Ring
n Correct Groove
at. #8-3487
Threads Lower O-Rin
Cat. #8-3486

5.02 Basic Troubleshooting Guide

W ARNING
There are extremely dangerous voltage and power levels present inside this unit. Do not attempt to diagnose or repair unless you have had training in power electronics measurement and troubleshoot­ing techniques.
C . No air flow at torch when air check switch is turned
on.
1. Input air connection is disconnected.
a. Connect the input air.
2. Input air supply not working.
a. Check the compressor manufacturer's manual
for trouble shooting and follow local mainte­nance procedures.
3. Internal connection is disconnected or loose.
a. Check all air line connections and fittings.
4. Filter or control PCB faulty.
a. Return to an authorized service center for re-
pair .
Manual 0-4678 5- 1 SERVICE
Page 22
D. T orch will not pilot when torch switch is activated.
g
Start Cartridge
A
g
Start Cartridge
E. Cut performance is diminished.
1. Gas pressure too high or too low.
a. Adjust gas pressure per pressure setting label
on power supply .
NOTE
It is possible to have enough air pressure to operate the power supply but not enough air flow to operate the torch.
2. Tor ch tip, start cartridge, or electrode missing.
a. Turn off power supply. Remove shield cup. In-
stall missing parts.
3. Start cartridge is stuck.
a. Turn off power supply. Remove shield cup, tip,
and start cartridge. Check lower end fitting on start cartridge for free movement. Replace car­tridge if lower end fitting does not move freely .
Lower End Fittin
1. Worn torch parts.
a. Check current setting. Check the Electrode and
Tip for excess wear .
New Electrode
rt # A-03284
Good Tip
Worn Electrode
Worn Tip
A-03406
b. Check that the lower end fitting on the start car-
tridge moves freely. Replace any or all parts as needed.
Art # A-03621
4. Worn or faulty torch parts
a. Inspect torch consumable parts. Replace if nec-
essary.
5. Thermal Switch activated
a. Allow the cooling fan to run for 2 minutes or
longer until it will resume operation.
NOTE
When operating the torch in a normal condition, a small amount of gas / air vents through the gap be­tween the shield cup and torch handle. Do not at­tempt to over tighten the shield cup as irreparable damage to internal components may result.
Art # A-04503
Lower End Fittin
Art # A-03621
Air will flow from gap next to shield cup.
SERVICE 5-2 Manual 0-4678
Page 23
2. Poor Work Lead connection.
Make a clean work cable
W A
Art # A-04389
a. Check the connection of the Work Lead to the
work piece.
connection to the work­piece or cutting table
ork Cable
nd Clamp
3. Current sensor or PWM PCB faulty.
a. Return to an authorized service center for re-
pair .
F . Air flows continuously and torch switch latch
button doesn't work properly .
1. Tor ch Switch Latch button on front panel faulty .
a. Return to an authorized service center for re-
pair .
2. Control PCB faulty.
a. Return to an authorized service center for re-
pair .

5.03 Contact information

Thermal Dynamics T echnical Service Dept. T el: 1-800-752-7622 (1-800-PLASMA2) Fax: 1-800-221-4401 e-mail address: tdc-tech@thermadyne.com
Manual 0-4678 5- 3 SERVICE
Page 24
This Page Left Blank
SERVICE 5-4 Manual 0-4678
Page 25

Appendix 1: Operating Sequence, Block Diagram

Primary Input Power "On" or Plugged in
Power Supply On/Off Switch "On"
Green Power Indicator "On" and Fan is Running
More air flow is required
Red Air Indicator
Release Torch Switch
Air Set Switch "On"
Air Flows at Torch. Set Air Pressure Then Turn Air Set Switch "Off"
Check Torch parts
Air Flow at Torch Stops
alignment. PIP switches need to be repaired by a Qualified Technician
for Torch to Pilot than to run the power supply. Re-check regulator setting.
Pilot Arc goes out
Pilot Arc Ignition
Torch Tip to Work after Pilot Arc start
Start Cutting Operation
YES
Post Flow of Air, Approximately 10 Seconds Then Stops
Note: The Torch will be very hot! Do not set on or near flammable materials!
Power Supply On/Off Switch "Off"
Cutting Done ?
Torch Switch "Off"
Torch Switch "On"
No Pilot Arc
NO
Green Power Indicator "Off" and Fan Stops
Art # A-04390
Primary Input Power Switch "Off" or Unplugged
Manual 0-4678 A-1 APPENDIX
Page 26

Appendix 2: Torch Connection

r
Art # A-04445
Disconnect power and air. Lay unit on its side. Remove access plate.
DETAIL
Negative / Plasma Lead
Power Supply Adapter
PIP
Switch
Torch
Switch
Torch Head
Negative / Plasma Lead
Black Orange
Green
White
Pilot
Torch Leads
Pilot
Work Cable
To Power Supply Adapte
Pilot
APPENDIX A-2 Manual 0-4678
Page 27

Appendix 3: Microchip Pin-Out

40 Pin Microchip
123456789101112
24222018161412108642 2321191715131197531
CPU
Socket on
Control
PCB
P2
P1
P3 123456789101112
Manual 0-4678 A-3 APPENDIX
Page 28

Appendix 4: Replacement Hand Torch Parts List

Item #QtyDescription Catalog #
1 1 T orch Handle Replacement Kit (include items no. 2 & 3) 9-7030 2 1 T rigger Assembly Replacement Kit 9-7034 3 1 Handle Screw Kit (5 each, #6-32 x 1/2" cap screw, and wrench) 9-8062 4 1 T orch Head Assembly Replacement Kit (includes items No. 5 & 6) 9-8219 5 1 Large O-Ring 8-3487 6 1 Small O-Ring 8-3486 7 Leads Assemblies with O2B Connectors (includes switch assemblies)
1 SL60 / 40Amp, 20 - foot Leads Assembly with O2B connectors 7-5241
8 1 Switch Kit 9-7031
APPENDIX A-4 Manual 0-4678
Page 29
7
1
2
4
5
6
3
8
7
A-07060
Manual 0-4678 A-5 APPENDIX
Page 30

Appendix 5: System Schematic Rev A

230 VAC
W
N/C
DIODE
Red
C1 C2
W
BL
DC 325
INPUT AC230V 1 PH
L
N
G
Black
White
To Ground Connection
NFB
230 VAC
TB1
Filter Board
No.40276003
CN2
W BR
TB2
CN1
W B
230 VAC
IGBT IGBT
R1
G1
E2 G4
E1 G2
G3 E4E3
B
PS Closes At 30 PSI
85Ω
B
AC230
Solenoid V/V
T1
Pressure Sensor
AC12
AC18
BK
AC18 VAC
R
FAN
BL
BL
R
Pale OR
OR
N.C SW
TW TW TW TW B W G R B W G R
E4 G3 G2
G4 E3
1
23 4123 4
+12VDC
W
TH
2
CN5
1
W
CN6
LD1 SOL
E1E2 G1
CN8
N/C
BL
R
N/C
CN1
+25VDC
2
CN4
1
+12VDC
2
CN7
1
Control Board
No.40271003
LD3 CO
CN2
16
1
Red
CN1
NOTE: Do Not attempt to adjust the POTs!
Art # A-04890
APPENDIX A-6 Manual 0-4678
MAIN
POWER
TEMP ERROR
Page 31
218 VAC
C/T 1
Main Transformer
194VAC
C3
R2
C4
R3
C5
R4
Piloting Current
Current Sensor
VC_1 VD_1 OU_1 GN_1
Cutting Current
WORK
OU_2
O.C.V. 325 Pilot 130 Cutting 110
C6
R5
REACTOR
WW
TORCH
LD2 Enable
+12VDC to engage Pilot Relay
Panel Board
No.40270601
AIR ERROR
HOLD
CN9
W Twisted
+12VDC
-12VDC
+12VDC
HOLD
AIR SET
CN10
CN12
CN3
CN11 N/C
Pilot Relay
PILOT
VC_1 VD_1 OU_1 VC_2 GN_1
BR
Red
V
Y G
Torch Filter
1 2
3 4 5
Y
1 2
Y
W
2
1
W
S/W
S/W
PCR
P.B.
Jumper
NOTE: Do Not attempt to adjust the POTs!
To Current Sensor
Y
77
Ω
10.3 MF
Pilot
Y
630V
POWWEL ELECTRONIC IND.CO., LTD.
Air Plasma 35A
2005 / 01 / 12
Art # A-04890
Manual 0-4678 A-7 APPENDIX
Page 32

Appendix 6: System Schematic Rev AB

230 VAC
W
N/C
DIODE
R
C1 C2
W
R1
Bk
DC 325
INPUT AC230V 1 PH
L
N
G
Bk
W
To Ground Connection
NFB
TB1
Filter Board
No.40276003
CN2
1
3
WW
TB2
CN4 CN3
CN1
33 3
111
WW
Bk
R1
R
IGBT IGBT
230 VAC
580
Ω
FAN
PS Closes At 30 PSI
230 VAC
AC230
85Ω
Bk
Solenoid V/V
Bk
Pressure Sensor
G1
E2 G4
E1 G2
G3 E4E3
TW TW TW TW B W G R B W G R
E4 G3 G2
G4 E3
1
23 4123 4
W
W
N/C
+12VDC
2
CN5
1
CN1
+25VDC
2
CN4
1
+12VDC
2
CN7
1
N/C
TH
T1
AC12
AC18
AC18
BL
BL
N/C
R
BK
R
BL
R
OR
OR
CN6
LD1 SOL
Control Board
No.40271003
CN2
16
E1E2 G1
CN8
LD3 CO
1
Red
CN1
NOTE: Do Not attempt to adjust the POTs!
Art # A-07023
APPENDIX A-8 Manual 0-4678
MAIN
POWER
TEMP ERROR
Page 33
218 VAC
C/T 1
Main Transformer
194VAC
C3
R2
C4
R3
C5
R4
Piloting Current
Current Sensor
VC_1 VD_1 OU_1 GN_1
Cutting Current
WORK
OU_2
O.C.V. 325 Pilot 130 Cutting 110
C6
R5
REACTOR
WW
TORCH
LD2 Enable
+12VDC to engage Pilot Relay
Panel Board
No.40270601
AIR ERROR
HOLD
CN9
W Twisted
+12VDC
-12VDC
+12VDC
HOLD
AIR SET
CN10
CN12
CN3
CN11 N/C
Pilot Relay
PILOT
VC_1 VD_1 OU_1
VC_2 GN_1
BR
Red
V
Y G
Torch Filter
1 2
3 4 5
Y
1 2
Y
W
2
1
W
S/W
S/W
PCR
P.B.
Jumper
NOTE: Do Not attempt to adjust the POTs!
To Current Sensor
Y
77
Ω
10.3 MF
Pilot
Y
630V
Air Plasma 35A (230 V)
No. 66001002 AB
2005 / 01 / 12
Art # A-07023
Manual 0-4678 A-9 APPENDIX
Page 34
This Page Left Blank
APPENDIX A-10 Manual 0-4678
Page 35

GLOBAL CUSTOMER SERVICE CONTACT INFORMATION

Thermadyne USA
2800 Airport Road Denton, Tx 76207 USA Telephone: (940) 566-2000 800-426-1888 Fax: 800-535-0557 Email: sales@thermalarc.com
Thermadyne Canada
2070 Wyecroft Road Oakville, Ontario Canada, L6L5V6 Telephone: (905)-827-1111 Fax: 905-827-3648
Thermadyne Europe
Europe Building Chorley North Industrial Park Chorley, Lancashire England, PR6 7Bx Telephone: 44-1257-261755 Fax: 44-1257-224800
Thermadyne Asia Sdn Bhd
Lot 151, Jalan Industri 3/5A Rawang Integrated Industrial Park - Jln Batu Arang 48000 Rawang Selangor Darul Ehsan West Malaysia Telephone: 603+ 6092 2988 Fax : 603+ 6092 1085
Cigweld, Australia
71 Gower Street Preston, Victoria Australia, 3072 Telephone: 61-3-9474-7400 Fax: 61-3-9474-7510
Thermadyne Italy
OCIM, S.r.L. Via Benaco, 3 20098 S. Giuliano Milan, Italy Tel: (39) 02-98 80320 Fax: (39) 02-98 281773
Thermadyne, China
RM 102A 685 Ding Xi Rd Chang Ning District Shanghai, PR, 200052 Telephone: 86-21-69171135 Fax: 86-21-69171139
Thermadyne International
2070 Wyecroft Road Oakville, Ontario Canada, L6L5V6 Telephone: (905)-827-9777 Fax: 905-827-9797
Page 36
Corporate Headquarters
16052 Swingley Ridge Road Suite 300 St. Louis, MO 63017
Telephone: 636-728-3000 Email: TDCSales@Thermadyne.com
www.thermadyne.com
Loading...