Installation and Operating Instructions
TW10i
CONTENTS Page
Introduction 1
Safety warnings 1
Key to main components 2
Water requirements 3
Electrical requirements 4 - 5
Fitting the unit to the wall 6
Plumbing connections 6
Electrical connections 7 - 8
Replacing the cover 8
Commissioning 9
Operating functions 9
Temperature / flow rate graphs 10
Spare parts 11
Fault finding 12
Instructions for service engineers only 13
Guarantee, service policy, etc. rear cover
To ensure the product suitability for commercial and multiple installations, please contact Triton’s specification advisory service prior to installation.
Telephone: (024) 7632 5491
Facsimile: (024) 7632 4564
E mail: technical@triton.plc.uk
TW10i
1
Due to continuous improvement and updating, specification may be altered without prior notice. Replacement parts can be ordered from Triton. See spare parts for details and part numbers.
INTRODUCTION
This book contains all the necessary fitting and operating instructions for your Triton TW10i water heater. Please read them carefully.
The heater installation must be carried out by a suitably qualified person and in the sequence of this instruction book.
Care taken during the installation will ensure a long and trouble-free life from your water heater.
Important: All plumbing connections must be completed before making the electrical connections.
SPECIFICATIONS
Electrical (UK only):
Nominal power Nominal power rating at 240V rating at 230V
9.5kW – (40A MCB rating) 8.7kW – (40A MCB rating)
Electrical (export only):
Nominal power rating at 230V
8kW – (35A MCB rating)
Nominal power rating at 230V
6kW – (30A MCB rating)
Water inlet connection:
15mm diameter 1/2 BSP nut and compression olive supplied.
Water outlet connection:
15mm diameter 1/2 BSP nut and compression olive supplied.
Entry points:
Water – bottom. Cable – top or back.
Materials:
Backplate - zinc plated mild steel. Cover – flame retardant ABS. Elements – Minerally insulated corrosion resistant metal sheathing.
Dimensions (in millimetres):
Height - 188; Width - 295; Depth - 85
When installed in accordance with this installation/instruction book, the TW10i unit then complies with the following standards and approvals:
Splashproof rating IPX4
Complies with requirements of current British and European safety standards for household and similar electrical appliances’.
Meets with Compliance with European Community Directives (CE).
ADVICE TO USERS
A
The electric heating elements operate at a constant rate. It is the flow rate of the water passing through the heater which determines the water temperature – the slower the flow, the hotter the water becomes and the faster the flow, the cooler the water.
B The heater can provide sufficient hot water for handwash purposes or low fill rates to a sink. If connected to two taps, they should not be operated simultaneously. During Winter, mains cold water entering the unit will be cooler than in Summer. Therefore the flow rate of hot water will vary between seasons.
C Switch off immediately at the isolating switch if water ceases to flow and contact Triton Customer Service.
SAFETY WARNINGS
1
The heater MUST NOT be used if suspected of
being frozen.
2 Switch off immediately at isolating switch if water ceases to flow during use.
3 If it is intended to operate the heater in areas of hard water it is advisable to fit a scale inhibitor (contact Triton for advice).
4 A thermal cut-out device is fitted to the elements to protect the unit under faulty conditions. If cut-out operates, see Operating Functions (overheat cut-out) or contact Triton Customer Service for advice.
TW10i
2
KEY TO MAIN COMPONENTS
1
Top cable entry
2 Back cable entry
3 Thermal cut-out
4 Water inlet
5 Wall screw fixings
6 Cover screw fixing
7 Earth connection
8 Terminal block
9 Flow switch
10 Hot water outlet
11 Relays
12 Can and element assembly
13 Cable clamp
1
6
7
8
9
5
4
10
11
12
13
2
3
5
1
6
7
8
9
5
4
10
11
12
13
2
3
5
Fig.1
3 relay
unit
Fig.2
2 relay
unit
NOTE: Not all wires have been depicted for reason of clarity.
NOTE: Not all wires have been depicted for reason of clarity.
TW10i
3
WATER REQUIREMENTS
WARNING:
This unit must NOT be positioned where it will be subjected to freezing conditions. For ease of servicing, the unit must always be mounted on the surface of tiled walls. Never tile up to the unit.
WATER: The installation must be in accordance with Water Regulations / Byelaws. To ensure correct operation of the heater, it must be connected to a cold mains water supply with a minimum and maximum running pressure as stated on the rating label situated inside the unit. Figure 3 shows a typical system layout. DO NOT use jointing compounds on any pipe fittings for the installation.
Isolating stopvalve
Mains water supply
Double
pole
isolating
switch
May be
wall mounted
in accordance
with IEE regs.
Mains electric supply (via double pole switch)
Separate permanently
connected supply
from consumer unit
TW10i unit
Fig.3
Diagrammatic view (not to scale)
NOTE: The TW10i heater is suitable for use with standard basin/sink taps but is NOT suitable for use with basin/sink mixer taps, shower mixer valves, bath taps, time delay taps, washing machines or similar appliances.