SmartOnline 208/240 & 120V 6kVA 5.4kW
Highlights
6kVA / 6000VA / 5400W on-line
double-conversion UPS; 0.9
power factor
208/120V or 240/120V 60Hz
output; Economy mode option
6U Rack/Tower installation;
Hot-swappable power and
battery modules
USB, RS232 & EPO ports;
Network management and
contact-closure card options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (3 wire); NEMA
5-15R, 5-15/20R & Hardwire
outputs
Package Includes
SU6000RT4UHVPM
Hot-swappable UPS Power
Module
SUPDMB6KHW Detachable PDU
with Maintenance Bypass Switch
SU6000XFMR2U Low voltage
transformer
PowerAlert Software CD
1 x 6-ft. USB Cable
1 x 6-ft. Serial Cable
4 Post Rackmount Hardware(2
sets)
Double-Conversion UPS, 6U Rack/Tower, Extended
Run, Network Card Options, USB, DB9 Serial,
Bypass Switch, Hardwire
MODEL NUMBER: SU6000RT4UTFHW
Description
Tripp Lite SU6000RT4UTFHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system offers
complete power protection for critical server, network and telecommunications equipment in a 6U rack/tower
compatible configuration. Full-time active power conditioning provides clean, continuous dual-conversion AC
output free of voltage fluctuations, power interruptions and line noise. Fault-tolerant auto-bypass prevents
unexpected service interruptions during UPS overload or internal fault conditions. Detachable back panel PDU
with manual bypass switch supports hot-swappable UPS power module replacement with no interruption to
connected equipment. 4U UPS power module and included 2U low-voltage transformer install in only 6 rack
spaces total(6U) with a maximum installed depth of only 21.8 in. / 55.3 cm. Maintains full-time sine wave output
within 2% of selectable 208/240V and 120V nominal at 60Hz during brownouts as low 100V and overvoltages as
high as 300V. Expandable runtime is supported with optional BP192V12-3U external battery packs. Battery
independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even
when batteries are expired and require replacement. Double-conversion operation converts raw input from AC to
DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional economy
mode significantly reduces BTU heat output and operating energy costs. Network-grade AC surge and noise suppression. Supports detailed monitoring of
equipment load levels, self-test data and utility power conditions via built-in RS-232 and USB interfaces. Optional network management card options, such as
Tripp Lite's SNMPWEBCARD network interface and additional contact-closure communications card accessories. HID-compliant USB interface enables
integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert monitoring software offers detailed
site power and UPS updates with support for safe auto-shutdown of connected systems as UPS batteries become depleted. Included software packages
include PowerAlert Local, PowerAlert Network Shutdown Agent and PowerAlert Network Management System for complete support for a wide variety of
application types. Supports Emergency Power Off(EPO) via built-in interface. Front panel LEDs and LCD readout with scroll controls support front-panel visual
monitoring of all major UPS for a variety of control options to support advanced UPS settings and configurations. LED / LCD display panel rotates for viewing
in rackmount or tower configurations. Hardwire input. Hardwire UPS output, plus 1 L6-30R, 8 5-15/20R and 4 5-15R outlets. External battery packs are field
replaceable and hot swappable.$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only)
Features
Tripp Lite SU6000RT4UTFHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a 6U rack/tower compatible configuration(4U power
module plus 2U low-voltage transformer)
Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Detachable back panel PDU contains input line cord connection, output receptacles and manual bypass switch to support hot-swappable whole UPS
replacement with no interruption to connected equipment
Hardwire input(208/240V L1, L2 + G)
Hardwire high and low voltage output, plus 8 5-15/20R and 4 5-15R 120V outlets
Included rail kit supports 4U 19 inch rackmount installation in 4 post racks
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks(2 required for SU6000RT4UTFHW)
Optional 2-9USTAND supports upright tower placement(1 required for SU6000RT4UTFHW)
Maximum installed rack depth of only 21.8 in. / 55.3 cm
Maintains full-time sine wave output within 2% of selected 208/240V and 120V nominal at 60Hz in double conversion mode
Corrects brownouts to 156V at full load(100V at 50% load or less)
Corrects overvoltages to 290V at full load(300V at 90% load or less)
Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced
protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs
Network-grade AC surge and noise suppression
Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot
interfaces
UPS card slot supports one card-based network interface option, such as Tripp Lite's SNMPWEBCARD network interface or dry-contact monitoring
accessory(part # RELAYIOCARD)
Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces
Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification
Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification(requires removal of USB
interface module)
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA(Network
Shutdown Agent) for larger networks and PowerAlert NMS(Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other
networking devices
Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major UPS functions with support for a variety of control
options to support advanced UPS settings and configurations
LED/LCD display panel rotates for viewing in rackmount or tower configurations
Supports Emergency Power Off(EPO) via built-in interface
Battery independent restart ensures automatic UPS power-up without userinteraction after lengthy power outages, even when batteries areexpired and
require replacement
BP192V12-3U external battery packs are field replaceable and hot swappable
Intelligent battery management system with temperature-compensated charging extends battery life
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software(see manual)
$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only)