Tripp-Lite SU6000RT4UHVHW Catalog Page

Tripp-Lite SU6000RT4UHVHW Catalog Page

SmartOnline 208/240, 230V 6kVA 5.4kW Double-Conversion UPS, 4U Rack/Tower, Extended Run, Network Card Options, USB, DB9 Serial, Bypass Switch, Hardwire

MODEL NUMBER: SU6000RT4UHVHW

Description

Featuring true on-line operation with pure sine wave output, zero transfer time to battery and complete UPS replacement capability with no downtime, the SU6000RT4UHVHW provides the highest level of protection available for mission-critical equipment from power outages, voltage fluctuations and transient surges. It converts incoming AC power to DC, and re-converts it back to filtered AC output with a pure sine wave, isolating connected components from all power problems in high-voltage environments. The SU6000RT4UHVHW has a 6kVA/5400W capacity and hardwire output.

With its detachable PDU with bypass switch, the SU6000RT4UHVHW is easily hot-swappable by a user of any skill set—no need for lengthy and expensive service calls, and no downtime if a repair or battery replacement is needed. In bypass mode, the PDU passes power to equipment without the use of the power and battery modules, allowing them to be removed while keeping your application in operation.

UPS battery backup keeps connected equipment operational through short power failures, and provides time to save data and perform an orderly system shutdown in case of a prolonged blackout. The SU6000RT4UHVHW’s runtime can be expanded with optional external battery packs.

The SU6000RT4UHVHW features a highly efficient(96%) economy mode setting that can significantly reduce a facility's energy costs by minimizing heat output, reducing cooling requirements and consuming less electricity.

An LCD display with LED indicators enables IT personnel to operating modes and conditions. The LCD/LED panel rotates for viewing in horizontal rack or vertical tower installations and includes an audible alarm that signals various conditions.

Highlights

Completely user hot-swappable—no service call or technician needed

Protects rackmount servers, telecom systems and other networking equipment in high-voltage environments with true on-line operation, pure sine wave output and zero transfer time to battery

Hardwire input and output with 200/208/220/230/240V 50/60Hz compatibility

6kVA/5400W capacity in 4U form factor with power module and independent, detachable PDU

Hot-swappable power and battery modules

8.5-minute half-load runtime, 2-minute full-load; expandable runtime with external battery packs

Front panel LEDs with detailed LCD monitoring and control screen

USB and RS232 communication ports with included PowerAlert software for complete network power management and control

$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)

Package Includes

SU6000RT4UHVPM

Hot-swappable UPS Power

Module

SUPDMB6KHW Detachable PDU

with Maintenance Bypass Switch

PowerAlert Software CD

1 x 6-ft. USB Cable

1 x 6-ft. DB9 Cable

4-Post Rackmount Hardware

The SU6000RT4UHVHW features a USB port and a DB9 port that, when used with Tripp Lite's included PowerAlert software, provide comprehensive network power monitoring and control. An optional network management accessory, such as Tripp Lite's SNMPWEBCARD network interface enables the UPS to operate as an IP managed device.

The unit requires only 4U of rack space in a standard rack enclosure and can be installed in a 2-post rack using the 2POSTRMKITHD accessory, or in a tower configuration with the 2-9USTAND accessory.

The SU6000RT4UHVHW comes with$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only) for connected equipment.

Features

Tripp Lite SU6000RT4UHVHW 6000VA / 6kVA / 5400 watt on-line, double-conversion UPS system in a single 4U rack/tower compatible housing

Full-time active power conditioning maintains clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise

Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions

Detachable back panel PDU contains hardwire input and output connections, plus manual bypass switch to support hot-swappable whole UPS replacement with no interruption to connected equipment

Hardwire input and output connections supported

Included rail kit supports 4U 19 inch rackmount installation in 4 post racks

Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks(1 required for SU6000RT4UHVHW)

Optional 2-9USTAND supports upright tower placement(1 required for SU6000RT4UHVHW)

Maximum installed rack depth of only 20.7 in. / 52.6cm inches

Maintains full-time sine wave output within 2% of selected 200/208/220/230/240V nominal in double conversion mode

Corrects brownouts to 156V at full load(100V at 50% load or less)

Corrects overvoltages to 290V at full load(300V at 90% load or less)

Supports 50/60Hz operation for worldwide frequency compatibility

Double-conversion operation offers full-time AC to DC, then DC to AC conversion to maintain perfectly regulated sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types

High efficiency ECONOMY MODE operation significantly reduces BTU heat output and operating energy costs

Network-grade AC surge and noise suppression

Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via built-in RS-232, USB and optional SNMP card slot interfaces

UPS card slot supports one card-based network interface option, such as Tripp Lite's SNMPWEBCARD, or dry-contact monitoring accessory(part # RELAYIOCARD)

Optional SNMPWEBCARD offers communications and control via secure remote web and network interfaces

Optional RELAYIOCARD supports six configurable hard contact closure outputs for custom event notification

Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification(requires removal of USB interface module)

HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X

Includes Free PowerAlert monitoring software packages; PowerAlert LOCAL for desktops and small business networks, PowerAlert NSA(Network Shutdown Agent) for larger networks and PowerAlert NMS(Network Management System) for monitoring up to 250 SNMP-enabled UPS, PDU and other networking devices

Front panel LEDs and LCD readout with scroll controls support front-panel visual monitoring of all major

UPS functions with support for a variety of control options to support advanced UPS settings and configurations

LED/LCD display panel rotates for viewing in rackmount or tower configurations

Supports Emergency Power Off(EPO) via built-in interface

Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and