SmartOnline 120V 3kVA 2.4kW Double-Conversion
Highlights
3000VA / 3kVA / 2400 watt
on-line double-conversion tower
UPS
110/120V +/-2% output at
50/60Hz, high efficiency
economy mode option
Expandable runtime,
Hot-swappable batteries
USB, RS232 & EPO ports;
network management card
options
Front panel status LEDs with
detailed load and battery metering
2 independently switchable
output load banks
NEMA L5-30P input; L5-30R,
5-15/20R & 5-15R outlets
Package Includes
SU3000XL Online,
Double-Conversion UPS System
PowerAlert Software and cabling
Instruction manual with warranty
information
UPS, Tower, Extended Run, Network Card Options,
USB, DB9 Serial
MODEL NUMBER: SU3000XL
Description
3000VA / 3kVA / 2400 watt on-line, double-conversion UPS system for critical server, network and
telecommunications equipment. Attractive upright tower format. Expandable battery runtime with optional
BP72V15-2U(limit 1), BP72V28RT-3U(multi-pack compatible) and BP72V18-2US(multi-pack compatible)
external battery packs. Full time sine wave 110/120V output with +/-2% voltage regulation. Uninterruptible Power
Supply(UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely
regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Up to 97% efficiency in
optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA L5-30R, NEMA 5-15/20R and NEMA 5-15R output
receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include
USB port, DB9 serial port and slot for network management card options, such as Tripp Lite's SNMPWEBCARD network interface. Built-in DB9 port offers
both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power
management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and
mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off(EPO) interface.
Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multi-stage metered current monitoring
and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. Field replaceable, hot
swappable internal batteries and external battery packs.$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only).
Features
SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications
Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak
operating hours and high efficiency, low BTU emission operation during off-peak times
Maintains continuous operation through blackouts, voltage fluctuations and surges
On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 110/120V(user selectable) with zero transfer time
Supports operation at 50/60Hz(auto-sensing)
Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
Corrects line voltage conditions as low as 65V and as high as 150V to within 2% of selected nominal voltage
Standard internal battery set offers 14 minutes runtime at half load(1200W) and 5 minutes at full load(2400W)
Expandable battery runtime with optional BP72V15-2U(limit 1), BP72V28RT-3U(multi-pack compatible) and BP72V18-2US(multi-pack compatible)
external battery packs
Intelligent battery management system extends battery life
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software(see manual)
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and slot for network management card options,
such as Tripp Lite's SNMPWEBCARD network interface
HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included
PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of
additional servers over IP
UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control, remote reboot and UPS nominal voltage adjustment
Built-in Emergency Power Off(EPO) interface with cable
NEMA L5-30P input plug / NEMA 5-15R, 5-15/20R & L5-30R output receptacles
Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks
Front panel LEDs offer current monitoring and battery charge level information
Network grade AC, TEL/DSL or ethernet line surge suppression
Field replaceable, hot swappable internal batteries and external battery packs
$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only)
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 3000
Output kVA Capacity (kVA) 3
Output Watt Capacity (Watts) 2400
Output kW Capacity (kW) 2.4
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150%
Output Capacity Details
Power Factor 0.8
Crest Factor 3:1
Nominal Output Voltage(s)
Supported
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start
Output Voltage Regulation (Line
Mode)
load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and
frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE
bypass limits)
110V; 120V
+/- 2%