Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU2200RTXL2UA
SmartOnline Expandable 2U Rack / Tower UPS System - On-line, double-conversion, sine wave UPS with PDU
switching, current monitoring and fault tolerant auto-bypass
Highlights
2200VA / 2.2kVA on-line, double-conversion, extended-run 2U rack / tower
UPS
Zero transfer time, on-line, double-conversion and economy-mode operation
supported
Maintains sine-wave 110/120V +/-2% output during overvoltages to 138 and
brownouts as low as 65V (50/60Hz auto-sensing)
Simultaneous communications via HID compliant USB port, serial port,
SNMP/Web card slot and EPO interface
Fault tolerant auto-bypass mode, current monitoring and switched PDU control
via 2 switchable output load banks
Input: NEMA 5-20P (120V) / Output: 6 NEMA 5-15/20R and 1 NEMA L5-20R
(120V)
2 year product warranty / $250,000 Ultimate Lifetime Insurance (USA &
Canada only)
Description
2200VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an
installed depth of only 19 in. Expandable battery runtime with optional BP48V24-2U and BP48V60RT-3U external battery packs. Full-time sine wave
110 or 120V +/-2% output. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then
re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and
overvoltages to 138V. NEMA 5-20P input plug; NEMA 5-15/20R and NEMA L5-20R output receptacles. Network-grade AC surge and noise
suppression. Zero transfer time between AC and battery operation. Highly efficient operation in optional economy mode setting, saving BTU heat
output and energy costs. Network management interfaces support simultaneous communications via USB port, DB9 serial port and
SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows
and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network
interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated 2-bank PDU switching
supports load shedding and remote-reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED
display panel easily rotates for better viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet
connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories
included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack & wallmount accessories available. Field-replaceable, hot-swappable internal
batteries and external battery packs. Attractive all-black color scheme. 2-year warranty and $250,000 connected equipment insurance; extended
warranty and service contracts available
Applications
Ideal for protection of critical 120V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or
tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM
workstations, concentrators, IP telephony and traditional PBX switching systems.