SmartOnline 208/240V 16kVA 14.4kW Double­Conversion UPS, N+1, 12U, Network Card Options, USB, DB9, Bypass, L6-30R, C19
MODEL NUMBER: SU16KRT
Description
Tripp Lite SU16KRT 16,000VA / 16kVA / 14,400 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in a 12U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 8kVA, and non-redundant operation at loads between 8 and 16kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
Features
Tripp Lite SU16KRT 16kVA, 16,000VA / 14,400 watt on-line, double-conversion UPS system in 12U total rack/tower configuration
Unique configuration offers 16kVA non-redundant operation and automatic N+1 redundancy at load levels of 8kVA and under
Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
Hardwire input; 2 L6-30R and 8 C19 outlets
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime with optional external battery packs
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX,
Highlights
16kVA / 16,000VA / 14,400W on-line double-conversion UPS;
0.9 power factor
200/208/220/230/240V 50/60Hz output
Hot-swap power and battery modules, N+1 fault tolerance at loads up to 8kVA
USB, RS232 & EPO ports; slot for network management card options
Front panel LEDs with detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
Hardwire input (3 wire); L6-30R & C19 outlets
Package Includes
Two SU8000RT3UPM UPS power modules
Two BP240V10RT3U battery packs
SUPDMB20K parallel PDU with Bypass switch
4 post rackmount installation rails
USB, DB9 & EPO cables
1 / 6
SNMPWEBCARD, MODBUSCARD and RELAYIOCARD (NOTE: Applications utilizing any supported network management card option, require the installation of two of the same model network card – install one card per included UPS power module)
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software (see manual)
Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries
Intelligent battery management system with temperature-compensated charging extends battery life
HID-compliant USB interface
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (4 required)
Optional 2-9USTAND supports upright tower placement (2 required)
Supports Emergency Power Off (EPO) via built-in interface
Front panel LEDs and LCD readout with scroll controls
LED / LCD display panel rotates for viewing in rackmount or tower configurations
External battery packs are field replaceable and hot swappable
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Specifications
OVERVIEW
UPC Code 037332158222 UPS Type On-Line
INPUT
Rated input current (Maximum Load) 92A (200V), 88.4A (208V), 76.6A (240V) Nominal Input Voltage(s) Supported 200V AC; 208V AC; 240V AC UPS Input Connection Type Hardwire UPS Input Connection Description 3 wire single phase input (L1, L2, G) Recommended Electrical Service 100A @ 200V, 208V, or 240V (L1, L2, G) Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 16000 Output kVA Capacity (kVA) 16 Output Watt Capacity (Watts) 14400
2 / 6
Output kW Capacity (kW) 14.4 Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30
seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power;
Double conversion mode is automatically restored as load levels are reduced to 95% or less Power Factor 0.9 Crest Factor 3:1 Nominal Voltage Details Voltage selection via front panel LCD interface Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to
50Hz or 50Hz to 60Hz (no de-rating) Output Voltage Regulation (Line
Mode) Output Voltage Regulation (Battery
Mode)
+/- 2%
+/- 2%
Output Circuit Breakers Two built-in 30A breakers protect one L6-30R outlet each; Eight built-in 20A breakers protect one C19 outlet each Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery
Mode) Nominal Output Voltage(s)
Supported
Pure Sine wave
200V; 208V; 240V
Output Receptacles (2) L6-30R; (8) C19 Individually Controllable Load Banks No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA) Full Load Runtime (min.) 5.5 minutes (14,400 watts) Half Load Runtime (min.) 13.5 minutes (7200 watts) Expandable Battery Runtime Runtime is expandable with external battery packs Expandable Runtime Yes Expandable Runtime Description For best results, add external batteries in multiples of two so that both included 8kVA power modules have an equal
number and type of connected battery packs External Battery Pack Compatibility  <a class="productLink" href="//www.tripplite.com/external-240v-tower-battery-pack-tripp-lite-3-phase-ups-
systems-3u~BP240V10RT3U">BP240V10RT3U</a> ;  <a class="productLink"
href="//www.tripplite.com/external-240v-battery-pack-select-tripp-lite-ups-systems-built-in-charger~BP240V787C-
1PH">BP240V787C-1PH</a>  DC System Voltage (VDC) 240 Battery Recharge Rate (Included
Batteries)
Less than 6 hours from 10% to 90% (typical, full load discharge)
Battery Replacement Description Hot-swappable, user replaceable external battery packs
VOLTAGE REGULATION
Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
3 / 6