Tripp-Lite SU16000RT4UHW Catalog Page

SmartOnline 208/240&120V 16kVA 11.2kW
Highlights
16kVA / 16,000VA / 11,200W
on-line double-conversion UPS,
split phase input
208/120V or 240/120V +/-3%
output at 60Hz, 94% Efficient
Economy-mode option
8U Rack/Tower compatible;
Hot-swappable power and
battery modules
USB, RS232 & EPO ports; slot
for network management card
options
Front panel LEDs with detailed
LCD monitoring and control
screen
Expandable runtime with optional
external battery packs
Hardwire input (4 wire split
phase); Hardwire output
Package Includes
SU16000RT4UHW UPS Power
Module
BP192V18-4U External battery
pack
SUPDMB16KHW Detachable
PDU with manual bypass switch
4-post rackmount installation
brackets
Double-Conversion UPS, 8U, Extended Run, Network Card Slot,USB,DB9,Bypass,Hardwire
MODEL NUMBER: SU16000RT4UHW
Description
Tripp Lite's SU16000RT4UHW SmartOnline Hot-Swappable Modular Rack/Tower UPS System provides
equipment. Maintains battery-derived AC output during blackouts with active, full-time power conditioning.
Fault-tolerant auto-bypass prevents unexpected service interruptions during overload or internal fault conditions.
4U power module and 4U external battery pack installs in 8 rack spaces(8U). Upright tower and two-post
rackmount installation supported with optional accessories. Maintains full-time sine wave output within 3% of
selectable 208/120 or 240/120V AC. Corrects brownouts and overvoltages from 65V to 140V(L-N). Expandable
runtime with optional external battery packs. Converts raw input from AC to DC, then resynthesizes output power
back to perfect sine wave AC output with enhanced protection from harmonic distortion, fast electrical impulses
and other hard-to-solve power problems not addressed by other UPS types. Highly efficient operation in optional
economy mode setting, saving BTU heat output and energy costs. Network-grade AC surge and noise suppression. Network management interfaces include
combination DB9 RS-232 enabled and dry contact serial port, enhanced USB port and slot for network management card options, such as Tripp Lite's
SNMPWEBCARD network interface. HID-compliant USB interface enables integration with built-in power management and auto-shutdown features of
Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all three network
interfaces. Includes PowerAlert monitoring software and complete cabling. Supports Emergency Power Off(EPO) via built-in interface. Front panel LEDs and
LCD readout with scroll controls support visual monitoring of all major UPS functions. LED/LCD display panel easily rotates for viewing in rackmount or tower
configurations. Split-phase, four-conductor hardwire input. UPS supports hardwire output. Output hardwire connections are mounted on a detachable
backplate with manual bypass switch to enable hot-swappable UPS replacement without powering off connected equipment. External battery packs are field
replaceable and hot swappable. Attractive all-black color scheme.$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only).
Features
True on-line, double-conversion UPS provides pure, full-time sine wave AC output free of surges, voltage fluctuations and line noise
16,000VA/11,200W output power capacity with dual voltage output of 208/120V or 240/120V
4U high power density power module and 4U external battery pack support rackmount installation in 8 rack spaces(8U)
Dual conversion UPS actively converts raw input from AC to DC, then back to perfect sine wave AC output with enhanced protection from harmonic
distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Hardwire input and output terminals are mounted on a detachable backplate with manual bypass switch to enable hot-swappable UPS replacement
without powering off connected equipment
Provides perfectly regulated, sine wave output power free of line noise, transient surges and frequency variation for the most efficient operation of critical
servers, networking and telecommunications equipment
Maintains output within 3% of selected 208/120V or 240/120V nominal voltage during brownouts and overvoltages
Supports connected equipment during blackouts for 12/5 min. at half/full load levels; runtime is further expandable with optional external battery
packs(Model BP192V18-4U)
Some external battery configurations require the use of Tripp Lite's External Battery Configuration Software(see manual)
Intelligent battery management system extends battery life
Highly efficient Economy-mode option
Network interfaces support simultaneous communications via DB9 port, USB port and slot for network management card options, such as Tripp Lite's
SNMPWEBCARD network interface
DB9 port supports RS-232 and dry contact messaging. HID-compliant USB interface enables integration with built-in power management and auto
shutdown features of Windows and Mac OS X
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number
of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery
capacity, AC line frequency, timed inverter shutoff, activate self-test and output power control
Built-in Emergency Power Off(EPO) interface with cable
Supports hardwire output at 208V and 120V
Split phase, four-conductor hardwire input connection on included detachable PDU
Front panel LEDs and LCD readout with scroll button enables visual confirmation of all major UPS functions and current site electrical conditions
Front panel switches enable power on/off control, self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4-post 19-in. rack enclosures
Optional 2-9USTAND tower stand set supports upright tower installation
Optional 2POSTRMKITHD accessory enables 2-post rackmount installation
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
$250,000 Ultimate Lifetime Insurance(U.S., Canada, and Puerto Rico only)
Specifications
OUTPUT
Output Volt Amp Capacity (VA) 16000
Output kVA Capacity (kVA) 16
Output Watt Capacity (Watts) 11200
Output kW Capacity (kW) 11.2
16,000VA, 11,200W (240V) / 13,860VA, 11,200W (208V); Supports up to 105% load continuously in double
Output Capacity Details
Power Factor 0.7
conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared
Loading...