Tripp Lite SU1500RTXL2U User Manual

Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU1500RTXL2U
Highlights
1500VA online 2U expandable rack / tower UPS
Enhanced serial communications port and SNMP/Web card slot
Maintains 120V +/-2% output during overvoltages to 138 and brownouts as low as 65V
2 load banks, 6 outlets
Fault tolerant auto-bypass
$250,000 Ultimate Lifetime Insurance (USA, Puerto Rico & Canada only)
Description
Tripp Lite's Smart Online SU1500RTXL2U on-line, double conversion UPS protects critical server, networking and telecommunications equipment
from blackouts, voltage fluctuations and transient surges. Multi-use form factor occupies only 2 rack spaces (2U) in standard 19 inch rackmount
configuration and includes tower stands to support upright placement. Large capacity 1.5kVA/1200 watt UPS continuously converts incoming AC to
DC, then back to perfect sine wave AC output at 120V AC (+/-2%). Removes harmonic distortion, fast electrical impulses, frequency fluctuations and
other hard-to-solve power problems not addressed by other UPS types. True sine wave output and zero transfer time offers guaranteed compatibility
with all equipment types. Includes 6 outlets arranged in two individually switchable load banks that can be independently controlled via software
interface to selectively reboot remote equipment, or shed less critical loads to extend battery runtime for more critical equipment. Battery support can
be extended indefinitely through the addition of external 2U rackmount battery packs (part# BP48V212U). Includes slot for internal SNMP/web card,
plus DB9 enhanced serial monitoring port for unattended shutdown, remote control and monitoring of UPS system and power data. Compatible with
Tripp Lite's Watchdog system service software.
Applications
Ideal for protection of critical 120V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.
Package Includes
SU1500RTXL2U Online Double-Conversion UPS System PowerAlert Software and cabling Mounting hardware for 4 post rack enclosures/tower stands Instruction manual with warranty information
Features
True on-line, double conversion UPS provides pure, sine wave AC output at all times Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time Removes harmonic distortion, electrical impulses, frequency variations and other hard to solve power problems Accepts input voltages between 80 and 138 (65 to 138 at loads under 70%), regulating output to 120V +/-2% 1500VA/1200 watt power capacity with 6 NEMA 5-15R outlets Standard internal battery set provides 17 minutes runtime at half load Expandable runtime with multiple external battery packs (part# BP48V212U) Innovative design makes unit adaptable for rackmount or tower applications (tower stands included)
Uses only 2 rack spaces (2U) in standard 19 inch rack DB9 serial port for network interface; SNMP compatible Slot for optional SNMP/web card (part# SNMPWEBCARD) PowerAlert unattended shutdown software and 6 ft. network cable included Compatible with Tripp Lite's Watchdog system service software Fault tolerant auto-bypass maintians continuous utility output to connected equipment, even in cases where the UPS is overloaded or suffers an internal failure that requires service Diagnostic LEDs Battery replacement door Mounting hardware included for 4 post rack enclosures, 2 post telecom rack compatible with separate purchase 2POSTRMKIT accessory $250,000 Ultimate Lifetime connected equipment insurance 2 year manufacturers product warranty
Specifications
OUTPUT
Frequency compatibility
50 / 60 Hz
Output VA 1500
Output watts 1200
Output nominal voltage
120V AC
Output voltage regulation
Maintains full-time sine wave output within 2% of 120V, less than 5% total harmonic distortion
Output frequency regulation
Regulates line frequency to 50/60Hz +/- 0.05Hz
Overload protection Via input breaker
Outlet quantity / type
6 NEMA 5-15R
Customized load management receptacles
"2 individually controllable load banks support automated load shedding and remote reboot on demand of locked network devices. Configurable via PowerAlert software to automatically switch off optional loads, like monitors, to increase available runtime for servers and other critical devices. (Bank A consists of 4 outlets / Bank B consists of 2 outlets) "
INPUT
UPS Input cord length (ft.)
10 ft. 12 gauge
Recommended Electrical Service
15A 120V
Maximum Input Amps (A)
12
Maximum Input Watts
1395
Input connection type
NEMA 5-15P
Voltage compatibility (VAC)
120
BATTERY
Expandable battery runtime
Supports extended runtime with optional external battery pack BP48V212U (multi-pack compatible)