Trimble HL700 User Manual

Captive Rod Clamp Screw - attaches to the back of detector.1. Alignment Points (2) - help secure and align rod clamp.2. Level Vial - can be viewed from above or below to verify that the 3.
rod is plumb. Clamping Screw Knob - secures clamp to rods by moving the 4.
traveling jaw. Clockwise tightens; Counterclockwise loosens. Reference Bar - top of bar is aligned with on-grade. 5. Traveling Jaw - moving jaw grips tightly to rods.6. Reversible Face - slanted face for round and oval rods; flat face 7.
for rectangular and square rods.
www.trimble.com
HL700 Laserometer
User Guide
EMC Declaration of Conformity
• Reorient or relocate the receiving antenna.
• Increase the separation between the laser and the receiver.
For more information, consult your dealer or an experience radio/television technician. CAUTION: Changes or modications to the receiver that are not ex- pressly approved by Trimble could void authority to use the equipment.
Declaration of Conformity
Application of Council Directive(s): 89/336/EEC Manufacturer’s Name: Trimble Navigation Ltd. Manufacturer’s Address: 5475 Kellenburger Road Dayton, Ohio 45424-1099 U.S.A. European Representative Address: Trimble GmbH Am Prime Parc 11 65479 Raunheim, Germany Model Number: HL700 Conformance to Directive(s): EC Directive 89/336/EEC using EN55022 and EN50082-1 Equipment Type/Environment: ITE/residential, commercial & light industrial Product Standards: Product meets the limit B and methods of EN55022 Product meets the levels and methods of IEC 801-2, 8 kV air, 4 kV contact IEC 801-3, 3 V/m 26 to 1000 MHz 80%, @ 1 kHz
1. Keypad - Power, Accuracy, Units & Volume switches.
2. LED Display - Green for on-grade, Red for high, Blue for low
3. Beeper output - Fast, solid & slow audible signal.
4. Bubble Vial - aids in keeping HL700 level.
5. Anti-strobe sensor - Reduces false indication from strobe lights.
6. SuperCell Reception Window - 5.0 in / 127.0 mm of height.
7. Front LCD - Displays elevation, settings and status.
8. On-grade Mark - Aligned with laser center on-grade reading.
9. Battery Door & Latch for two “AA” batteries.
10. Marking Notch (3.15 in / 80.0 mm from top).
11. Captive Screw Thread, Center on-grade clamp position.
12. Captive Screw Thread, Offset on-grade clamp position.
13. Clamp Guides - Dimples align rod clamp.
14. Serial Number / ID Label.
15. Rear LCD - repeats indications of front LCD.
16. Rubber over mold - Protects the unit from drops
4
6 7
5
1
2
3
8
9
10
11
12
14
15
16
13
Front view
Rear view
Working Radius: 1 m - 460 m (3 ft - 1500 ft) (Laser dependent): Laser Detection Height: 127.0 mm (5“) Numeric Readout Height: 102.0 mm (4“) Accuracy (Dead band): Ultra Fine 0.5 mm 0.02 in 1/32 in Super Fine 1.0 mm 0.05 in 1/16 in Fine 2.0 mm 0.10 in 1/8 in Medium 5.0 mm 0.20 in 1/4 in Coarse 10.0 mm 0.50 in 1/2 in Calibration 0.1 mm 0.01 in 1/64 in Reception Angle: ± 45° minimum Detectable Spectrum: 610 nm ... 780 nm Beeper Volumes: Loud = 110 dBA Medium = 95 dBA Low = 65 dBA LED Grade Indicators: Front, Green on-grade, Red Hi, Blue Low Power Supply: 2 x 1.5 Volt “AA” batteries Battery Life: 60+ hours Automatic Shut Off: Selectable, 30 min, 24 h, Off Environmental: Waterproof, Dustproof to IP67 Weight without clamp: 371 g (13.1 oz.) Dimensions without clamp: 168.0 x 76.0 x 36.0 mm (6.6” x 3.0” x 1.4”) Operating Temperature: -20°C...+60°C (-4°F... +140°F) Storage Temperature: -40°C...+70°C (-40°F...+158°F)
*Specifications subject to change without notice.
Trimble warrants the HL700 to be free of defects in material and work­manship for a period of three years. Trimble or its authorized service center will repair or replace, at its option, any defective part, or the entire product, for which notice has been given during the warranty period. If required, travel and per diem expenses to and from the place where repairs are made will be charged to the customer at the prevailing rates. Customers should send the product to Trimble Navigation Ltd. or the nearest authorized service center for warranty repairs or exchange, freight prepaid. Any evidence of negligent, abnormal use, accident, or any attempt to repair the product by other than factory-authorized
voids the warranty. The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment. Trimble will not be held responsible for any consequential loss or damage of any kind. This warranty is in lieu of all other warranties, except as set forth above,
including any implied warranty merchantability of tness for a particular
purpose, are hereby disclaimed. This warranty is in lieu of all other warranties, expressed or implied.
Battery Status
Rod Clamp
Move clamp position
Notice to Our European Union Customers
For product recycling instructions and more information,
please go to: www.trimble.com/environment/summary.html
Recycling in Europe
To recycle Trimble WEEE,
call: +31 497 53 2430, and ask for the “WEEE associate,” or
Mail a request for recycling instructions to:
Trimble Europe BV c/o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel, NL
1. Open the battery door using a coin or similar pry device to release the battery door tab.
2. Insert two AA batteries noting the plus (+) and minus (-) diagrams inside the battery housing.
3. Close the battery door. Push down until it “clicks” into the locked position.
Trimble Construction Division 5475 Kellenburger Road Dayton, Ohio 45424-1099 U.S.A. +1-937-245-5600 Phone
www.trimble.com
© 2009, Trimble Navigation Limited. All rights reserved.
Reorder PN 1277-3850 C (11/09)
Specications
Warranty
Installing the Batteries
N324
Offset on-grade clamp position - clamp position is sensed automatically and displayed. Offset clamp position moves the on-grade location to allow more grade information to be displayed above grade. This is useful in applications where going below grade is not required, i.e. driving stakes down to grade.
Flashing -
Change
Batteries
Outline -
Approx. 30 Minutes Remaining
Full -
Batteries
OK
Half -
Initial
Warning
5
4
2
1
6
7
3
HL700_User_Guide_1277-3990 Rev C.indd 1 11/5/2009 2:13:39 PM
A) HL700 is in the laser beam and the power is on:
Press any switch to return to normal operation.
The current elevation read­ing will be held. A flashing display will confirm the reading has been captured
.
1 x quick
B) HL700 is out of the laser beam and power is on:
A short intermittent beep (The beeper will turn on to Low if turned off.)
+
1.
Press any switch to return to normal operation.
2. Place the HL700 in the beam. (Example:
Fasten it to a measuring rod, bring the HL700 into the laser beam. You now have 5 seconds to plumb the rod and get the reading captured.)
The beeper will chirp rapidly after approximately 5
seconds to confirm beam capture. A flashing display will also indicate the reading has been captured
.
+
1 x quick
Special Menu Functions
SENS Sensitivity Medium*-HighLow AVG Averaging algorithm Medium*High - Low D.R.O. Numeric display ON*-OFF-.1mm UNIT Units of measure MM*-CM-IN-FRAC-FT FRC.R. Fractional Reduction ON*-OFF ARRW Arrow Display DB*(deadband)-PR (prop.) O.O.B. Out-of-Beam Display ON*-OFF GRD.A. Grade Alarm ON-OFF* A.S.O. Automatic shutoff 0.5h*-24h-OFF TX.O.L. Transmitter Out-of-Level OFF*RPS TX.O.B. Transmitter Low Battery OFF*-RPS INFO Information about the Laserometer
(for 2 Sec., then SENS)
Press switches together for 2 sec
.
1. Scrolling up or down.
How to change Menu functions:
2. Enter Change mode.
3. Change selected items
.
4. Confirm change.
5. To Exit.
or
+
Change special Menu Functions only in the case of special job requirements!
Automatic Shutoff A.S.O. (Automatic Shut Off):
0.5 - After 30 Minutes* OF - Off (Unit is permanently on.) 24 - 24 hour shutoff.
Out-of-Beam Display O.O.B. (Out-of-Beam Display):
Sequence to show direction to get back in the laser beam ( for 25 s) ON - Out-of-Beam Display ON* OF - Out-of-Beam Display OFF
Grade Alarm GRD.A. (Grade Alarm):
When turned ON, disables the audible signal when on-grade. When moved out of the on-grade deadband, the beeper activates as normal: ON - Alarm on (Solid beeper OFF) OF - Alarm off (Solid beeper ON)*
* Default setting
For more information about special Menu Function contact the manu-facturer, importer or your local dealer
.
Sensitivity of reception SENS (Sensitivity):
Selects reception sensitivity to laser and other light sources.
MD - Medium*: for most applications. HI - High: When laser beam is
weak, or at very long distances. LO - Low: If outside sources are disturbing elevation readings
.
Action Display Remarks
Initialization:
1. Test of LCD, LED and beeper
2. CAL: Calibration (3 sec.)
3. Unit is ready for use.
(Do not power up the unit in a laser beam or strobe. If detected, the unit will display “E200” and revert to the previous calibration.)
The selected unit of measure determines the displayed deadband (accuracy).
The current accuracy is stored in memory and will be retained when the unit is turned off or when batteries are replaced.
The current beeper volume is stored in memory and will be retained when the unit is turned off or when bat­teries are replaced.
The current unit of measure is stored in memory and will be retained when the unit is turned off or when batteries are replaced.
The current brightness of LEDs is stored in memory and will be retained when the unit is turned off or when batteries are replaced.
Action Display Remarks
Accuracy in mm:
0.5 1.0 2.0 5.0 10.0
Beeper
Loud
Beeper
Medium
Beeper
Low
(No symbol)
mm - cm - in - frac - ft
LEDs Bright
LEDs
Dim
LEDs
OFF
(No symbol)
1
2
3
Turn power ON/OFF
Press to turn power ON. Press and hold for 2 seconds to turn power OFF.
Press once to display current setting; push again to scroll through options.
Press together to cycle the selection.
+
Press once to display current setting, additional pushes to scroll through options.
Select accuracy
Select beeper volume
Select units of measure
Select brightness of LEDs
CAPTURE Function
Press once to change current setting (A beep confirms the selected volume.)
Beeper
Off
HL700_User_Guide_1277-3990 Rev C.indd 2 11/5/2009 2:13:44 PM
Loading...