Trademark, copyright, and product classification information ......................................................................... iii
Trademark.................................................................................................................................................. iii
Copyright restrictions ................................................................................................................................. iii
FCC warning .............................................................................................................................................. iii
CE Mark ..................................................................................................................................................... iii
About this product and manual ....................................................................................................................... iv
Industrial Switch......................................................................................................................................... iv
Term/usage................................................................................................................................................ iv
About this manual ...................................................................................................................................... iv
Manual structure ........................................................................................................................................ iv
Cautions and warnings .................................................................................................................................... v
Cautions and warnings................................................................................................................................ v
Warnings.................................................................................................................................................... vi
Section I ....................................................................................................................................................................1
In this section ..............................................................................................................................................1
General description..........................................................................................................................................2
SISTF1010-150 Industrial Unmanaged Switch part numbers ..........................................................................3
Standard models.........................................................................................................................................3
Front panel..................................................................................................................................................5
Back panel ..................................................................................................................................................6
Section II ...................................................................................................................................................................7
In this section ..............................................................................................................................................7
DIN rail mounting .............................................................................................................................................8
DIN rail clip..................................................................................................................................................8
DIN rail mounting considerations ................................................................................................................8
DIN rail mounting ........................................................................................................................................9
Wall mount bracket ...................................................................................................................................10
Wall mount bracket install .........................................................................................................................10
Grounding the Industrial Switch .....................................................................................................................11
Advanced Features .................................................................................................................................................18
In this section ............................................................................................................................................18
In this section ............................................................................................................................................20
In this section ............................................................................................................................................22
Troubleshooting problem and corrective action table ....................................................................................23
Compliance Information ..........................................................................................................................................24
In this section ............................................................................................................................................24
Live Web chat ...........................................................................................................................................25
This warranty is your only remedy.............................................................................................................27
Compliance information .................................................................................................................................28
This equipment has been tested and found to comply with the limits for class A devices,
pursuant to part 15 of FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a commercial installation. This equipment
generates, uses, and radiates radio frequency energy; therefore, if it is not installed and
used in accordance with the instructions in this document, could cause harmful
interference to radio communications. Operation of this equipment in a residential area
is likely to cause harmful interference; the user will be required to correct the interference
at the user’s own expense.
CE Mark
CE Marking (European Conformity): This is a Class A product. In a domestic
environment, this product could cause radio interference; as a result, the user may be
required to take adequate preventative measures.
The SISTF1010-150-LR(T) Industrial Unmanaged Switch provides five 10/100Base-TX (RJ-
45) copper connections. These switches are hardened devices designed to reliably operate in
harsh environments such as those found on factory floors, outdoor enclosures or other
hazardous environments.
In this manual, the term “Industrial Switch” (first letter upper case) refers to the
SISTF1010-150-LR(T) 10/100Base-TX Industrial Unmanaged Switch.
This manual provides instructions on how to install, configure, and operate the
SISTF1010-150-LR(T) 10/100Base-TX Industrial Unmanaged Switch.
This manual has a beginning table of contents; also, at the beginning of each section there is
a table of contents. As you traverse the manual, note the side headings. These side
headings make it easier to find specific information. The manual sections are as follows:
Section Description
I Industrial Switch general description, ordering information, package
contents and physical features/description
II Installation and operation of the Industrial Switch
III Advanced features
IV Cable Specifications
V Troubleshooting
VI Contacting Transition Networks, product warranty and product compliance
information
Appendix A Presents product specifications, notices, and warnings
Make sure that you read and understand all content identified by these two symbols:
Cautions and warnings appear here and throughout this manual where appropriate. Failure to
read and understand the information identified by the “caution” and “warning” symbols could
result in poor equipment performance, damage to equipment, or injury to persons.
Cautions indicate the possibility of damage to equipment.
CAUTION
Make sure that the Industrial Switch is mounted with proper space around it for ventilation
(heat dissipation). Failure to observe this caution could result in damage to the Industrial
Switch.
CAUTION
Please exercise caution when using power tools. Do not install this unit in damp or wet
locations, or in close proximity to very hot surfaces. Failure to observe this caution could
result in damage to the Industrial Switch and cables.
CAUTION
Only qualified persons should install the Industrial Switch. Failure to observe this caution
could result in poor performance or damage to the Industrial Switch.
CAUTION
Install the Industrial Switch in an environment where the temperature range will not
exceed the stated environmental specifications for the particular model being installed.
Failure to observe this caution could result in permanent damage to the Industrial Switch.
CAUTION
DO NOT install the Industrial Switch in areas where strong electromagnetic fields (EMF)
exist. Failure to observe this caution could result in poor Industrial Switch performance
and data corruption.
CAUTION
The Industrial Switch must be mounted to a well-grounded surface. Failure to observe
this caution could result in EMI problems.
CAUTION
When connecting DC power wires to the terminal-block plug, pay close attention to the
polarity markings shown near the terminal block of the Industrial Switch. Failure to
observe this caution could result in damage to the equipment.
CAUTION
This is a Class A product. In a residential environment, this product could cause radio
interference in which case the user may be required to take adequate corrective
measures.
The SISTF1010-150 Industrial Unmanaged Switch can help aggregate and transport data
from copper-based industrial networking and communication devices. Each Industrial Switch
can connect to either 10Base-T or 100Base-TX copper ports and is offered in two distinct
operating temperature ranges:
- Standard: 0°C to +60°C (32°F to +140°F)
- Extended: -40°C to +75°C (-40°F to +167°F)
The SISTF1010-150 Industrial Unmanaged Switch has the following features:
• Auto-Negotiation
• AutoCrossTM
• Dual, redundant auto-sensing 12 to 48VDC inputs with reverse polarity protection
and over current protection
•IEEE 802.3x flow control support
Flow control on full-duplex
Back pressure on half-duplex
• 512KB Embedded memory
• 1K MAC address table
• DIN-Rail mounting bracket (installed)
• Wall mount bracket included
• Barrel connector interface cable included for use with external AC/DC power supply
- For external AC/DC power supply (sold separately)
Compare the package contents of your industrial Switch with the standard checklist above. If
any item is damaged or missing, please contact Transition Networks Technical Support.