Transition Networks SISPM1040-182D User Manual

Page 1
8 10/100TX + 2 10/100/1000T/Mini-GBIC
Combo with 8 PoE Injector Industrial Switch
User Manual
SISPM1040-182D
Version 1.01
October, 2009
Page 2
Transition Networks SISPM1040-182D
Document
Date Revision Initials
Release
1.00 Oct 31, 2008 First release A.E.F
1.01 Oct 21, 2009 Corrections A.E.F
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 3
Transition Networks SISPM1040-182D
Notice
The contents of this manual are based on the table below listing
firmware version, kernel version, and hardware version. If the
switch functions are different from the description of the manual,
please contact the local sale dealer for more information.
Firmware Version
Kernel Version
Hardware Version
V1.00
V1.56
----------
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 4
Transition Networks SISPM1040-182D
FCC Warning
This Equipment has been tested and found to comply with the limits for a
Class-A digital device, pursuant to Part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy. It may cause harmful interference to radio
communications if the equipment is not installed and used in accordance
with the instructions. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 5
Transition Networks SISPM1040-182D
Content
Chapter 1 Introduction......................................... 1
1.1 Hardware Features...................................... 1
1.2 Software Features ....................................... 5
1.3 Package Contents ....................................... 8
Chapter 2 Hardware Description ........................ 9
2.1 Physical Dimension ..................................... 9
2.2 Front Panel.................................................. 9
2.3 Bottom View .............................................. 10
2.4 LED Indicators........................................... 11
Chapter 3 Hardware Installation ....................... 13
3.1 Installation Steps ....................................... 13
3.2 DIN-Rail Mounting ..................................... 14
3.3 Wall Mount Plate Mounting ....................... 16
3.4 Wiring the Power Inputs ............................ 17
3.5 Wiring the Fault Alarm Contact ................. 18
3.6 Cabling ...................................................... 19
Chapter 4 Network Application......................... 23
4.1 X-Ring Application..................................... 25
4.2 Coupling Ring Application ......................... 26
4.3 Dual Homing Application ........................... 27
4.4 Dual Ring Application ................................ 28
Chapter 5 Console Management ...................... 29
5.1 Connecting to the Console Port ................ 29
5.2 Pin Assignment ......................................... 29
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 6
Transition Networks SISPM1040-182D-LR
5.3 Login in the Console Interface................... 30
5.4 CLI Management....................................... 32
5.5 Commands Level ...................................... 32
Chapter 6 Web-Based Management................. 34
6.1 About Web-based Management................ 34
6.2 Preparing for Web Management ............... 34
6.3 System Login............................................. 35
6.4 System Information ................................... 36
6.5 IP Configuration......................................... 37
6.6 DHCP Server............................................. 39
6.7 TFTP ......................................................... 43
6.8 System Event Log ..................................... 46
6.9 Fault Relay Alarm...................................... 52
6.10 SNTP Configuration ................................. 53
6.11 IP Security ................................................ 57
6.12 User Authentication .................................. 59
6.13 Port Statistics ........................................... 60
6.14 Port Control .............................................. 62
6.15 Port Trunk................................................. 64
6.16 Port Mirroring............................................ 74
6.17 Rate Limiting ............................................ 75
6.18 VLAN configuration .................................. 77
6.19 Rapid Spanning Tree ............................... 87
6.20 SNMP Configuration................................. 91
6.21 QoS Configuration.................................... 97
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 7
Transition Networks SISPM1040-182D-LR
6.22 IGMP Configuration................................ 100
6.23 X-Ring..................................................... 102
6.24 LLDP Configuration ................................ 105
6.25 Security—802.1X/Radius Configuration. 106
6.26 MAC Address Table ............................... 110
6.27 Power over Ethernet............................... 115
6.28 Factory Default ....................................... 117
6.29 Save Configuration................................. 118
6.30 System Reboot....................................... 119
Troubles shooting ................................................. 120
Appendix A—RJ-45 Pin Assignment ................... 121
RJ-45 Pin Assignments........................................ 121
RJ-45 Pin Assignment of PoE.............................. 124
Appendix B—Command Sets............................... 126
System Commands Set ....................................... 126
Port Commands Set............................................. 128
Trunk Commands Set .......................................... 131
VLAN Commands Set.......................................... 132
Spanning Tree Commands Set............................ 134
QOS Commands Set ........................................... 137
IGMP Commands Set .......................................... 138
Mac / Filter Table Commands Set ....................... 138
SNMP Commands Set......................................... 139
Port Mirroring Commands Set ............................. 142
802.1x Commands Set ........................................ 142
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 8
Transition Networks SISPM1040-182D-LR
TFTP Commands Set .......................................... 145
SystemLog, SMTP and Event Commands Set.... 145
SNTP Commands Set.......................................... 147
X-ring Commands Set.......................................... 148
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 9
Transition Networks SISPM1040-182D
Chapter 1 Introduction
The 8 10/100TX + 2 10/100/1000T/Mini-GBIC Combo w/8 PoE Injectors Managed
Industrial Switch is a cost-effective solution and meets the high reliability requirements
demanded by industrial applications. Fiber can extend the connection distance to
increases the network elasticity and performance. In addition, the industrial switch
provides the PoE function for Powered Devices to receive power as well as data over
the RJ-45 cable.
1.1 Hardware Features
IEEE 802.3 10Base-T Ethernet
Standard
Switch
Architecture
IEEE 802.3u 100Base-TX/ FX
IEEE802.3ab 1000Base-T
IEEE802.3z Gigabit fiber
IEEE802.3x Flow Control and Back Pressure
IEEE802.3ad Port trunk with LACP
IEEE802.3af Power over Ethernet
IEEE802.1d Spanning Tree/ IEEE802.1w Rapid Spanning
Tree
IEEE802.1p Class of Service
IEEE802.1Q VLAN Tag
IEEE 802.1x User Authentication (Radius)
IEEE802.1ab LLDP
Back-plane (Switching Fabric): 5.6Gbps
Packet throughput ability(Full-Duplex): 8.3Mpps @64bytes
14,880pps for Ethernet port
Transfer Rate
Packet Buffer
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
148,800pps for Fast Ethernet port
1,488,000pps for Gigabit Fiber Ethernet port
1Mbits
Page 10
Transition Networks SISPM1040-182D-LR
MAC Address
Flash ROM
DRAM
Connector
Network Cable
8K MAC address table
4Mbytes
32Mbytes
10/100TX: 8 x RJ-45
10/100/1000T/ Mini-GBIC Combo: 2 x RJ-45 + 2 x
100/1000 SFP sockets
RS-232 connector: RJ-45 type
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E cable
EIA/TIA-568 100-ohm (100m)
100Base-TX: 2-pair UTP/STP Cat. 5/ 5E cable
EIA/TIA-568 100-ohm (100m)
1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E cable
EIA/TIA-568 100-ohm (100m)
Optical Fiber
Distance:
Multi mode:
0 to 5 km, 1300 nm (50/125 ȝm, 800 MHz*km)
0 to 4 km, 1300 nm (62.5/125 ȝm, 500 MHz*km)
Single mode:
0 to 40 km, 1310 nm (9/125 ȝm, 3.5 PS/(nm*km))
0 to 80 km, 1550 nm (9/125 ȝm, 19 PS/(nm*km))
Min. TX Output:
Multi mode: -20 dBm
Single mode: 0 to 40 km, -5 dBm; 0 to 80 km, -5 dBm
Max. TX Output:
Multi mode: -14 dBm
Single mode: 0 to 40 km, 0 dBm; 0 to 80 km, 0 dBm
Sensitivity:
-36 to -32 dBm (Single mode); -34 to -30 dBm (Multi mode)
PoE pin
assignment
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
RJ-45 port # 1~# 8 support IEEE 802.3af End-point,
Alternative A mode. Per port provides 15.4W ability.
2
Page 11
Transition Networks SISPM1040-182D-LR
Positive (VCC+): RJ-45 pin 1,2.
Negative (VCC-): RJ-45 pin 3,6.
Protocol
LED
Power Supply
Power
Consumption
Operating
Humidity
Operating
Temperature
CSMA/CD
Per unit: Power (Green), Power 1 (Green), Power 2
(Green), Fault (Red), Master (Green), FWD (Green)
8 port 10/100: Link/Activity (Green), Full duplex/Collision
(Amber)
SFP port: LNK/ACT(Green), 1000T: LNK/ACT(Green),
1000M(Green)
External Power Supply: DC 48V, Redundant power DC 48V
and connective removable terminal block for master and
slave power
116Watts (Full load)
5% to 95% (Non-condensing)
o
Standard: -10
Wide Operating Temperature: -40
C ~ 60oC
o
C ~ 75oC
Storage
-40
o
C ~ 85oC
Temperature
Case Dimension
Fan Number
Installation
IP-30, 72mm (W) x 105mm (D) x 152mm (H)
0
DIN rail and wall mount ear
FCC Class A, CE EN61000-4-2, CE EN61000-4-3, CE EN-
61000-4-4, CE EN61000-4-5,
EMI
CE EN61000-4-6, CE EN61000-4-8, CE EN61000-4-11, CE
EN61000-4-12, CE EN61000-6-2, CE EN61000-6-4
Safety
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
UL, cUL, CE/EN60950-1
3
Page 12
Transition Networks SISPM1040-182D-LR
Stability Testing
IEC60068-2-32 (Free fall), IEC60068-2-27 (Shock),
IEC60068-2-6 (Vibration)
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
4
Page 13
Transition Networks SISPM1040-182D-LR
1.2 Software Features
Management
SNMP MIB
VLAN
Port Trunk with
LACP
LLDP**
Spanning tree
SNMP v1 v2c, v3/ Web/Telnet/CLI
RFC 1215 Trap, RFC1213 MIBII, RFC 1157 SNMP MIB, RFC 1493
Bridge MIB, RFC 2674 VLAN MIB, RFC 1643 , RFC 1757, RSTP MIB,
Private MIB, LLDP MIB
Port Based VLAN
IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K,
VLAN ID can be assigned from 1 to 4096.)
GVRP (256 Groups)
LACP Port Trunk: 4 Trunk groups/Maximum 4 trunk
members
Supports LLDP allowing switch to advertise its identification
and capability on the LAN
IEEE802.1d spanning tree
IEEE802.1w rapid spanning tree.
Supports X-ring, Dual Homing, Couple Ring and Dual Ring
Topology
X-Ring
Provides redundant backup feature and the recovery time
below 20ms
The quality of service determined by port, Tag and IPv4
Quality of Service
Type of service, IPv4/IPv6 Different Service
Supports IEEE802.1p class of service, per port provides 4
Class of Service
priority queues
Supports 100 entries of MAC address for static MAC and
Port Security
another 100 for MAC filter
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
5
Page 14
Transition Networks SISPM1040-182D-LR
Port Mirror
IGMP
IP Security
Login Security
Bandwidth
Control
Supports 3 mirroring types: “RX, TX and Both packet”.
Supports IGMP snooping v1,v2
256 multicast groups and IGMP query
Supports 10 IP addresses that have permission to access
the switch management and to prevent unauthorized
intruder.
Supports IEEE802.1X Authentication/RADIUS
Support ingress packet filter and egress packet limit
The egress rate control supports all of packet type and the
limit rates are 100K~102400Kbps(10/100),
100K~256000Kbps(1000)
Ingress filter packet type combination rules are
Broadcast/Multicast/Unknown Unicast packet,
Flow Control
System Log
SMTP
Relay Alarm
SNMP Trap
Broadcast/Multicast packet, Broadcast packet only and all
of packet. The packet filter rate can be set from
100K~102400Kbps(10/100), 100K~256000Kbps(1000)
Supports Flow Control for Full-duplex and Back Pressure
for Half-duplex
Supports System log record and remote system log server
Supports SMTP Server and 6 e-mail accounts for receiving
event alert
Provides one relay output for port breakdown, power fail
Alarm Relay current carry ability: 1A @ DC24V
1. Cold start
2. Link down
3. Link up
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
6
Page 15
Transition Networks SISPM1040-182D-LR
4. Authorization fail
5. PD disconnect trap-PoE port event
DHCP
DNS
SNTP
Firmware Update
Configuration
Upload/Download
ifAlias
Provides DHCP Client/ DHCP Server/ Port and IP Binding
Provides DNS client feature and supports Primary and
Secondary DNS server
Supports SNTP to synchronize system clock in Internet
Supports TFTP firmware update, TFTP backup and restore.
Supports binary format configuration file for system quick
installation
Each port allows importing 128bits of alphabetic string of
word on SNMP and CLI interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
7
Page 16
Transition Networks SISPM1040-182D-LR
1.3 Package Contents
Please refer to the package content list below to verify them against the checklist.
8 10/100TX + 2 10/100/1000T/Mini-GBIC Combo w/8 PoE Injectors Managed
Industrial Switch x 1
User manual x 1
Pluggable Terminal Block x 1
Mounting plate x 2
RJ-45 to DB9-Female cable x 1
Compare the contents of the industrial switch with the standard checklist above. If any
item is damaged or missing, please contact the local dealer for service.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
8
Page 17
Transition Networks SISPM1040-182D
Chapter 2 Hardware Description
This chapter will describe the Industrial switch’s hardware spec, port, cabling information,
and wiring installation.
2.1 Physical Dimension
8 10/100TX w/ X-Ring Managed Industrial Switch dimension (W x D x H) is 72mm x
105mm x 152mm
2.2 Front Panel
The Front Panel of the 8 10/100TX w/ X-Ring Managed Industrial Switch is shown as
below:
Front Panel of the industrial switch
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 18
Transition Networks SISPM1040-182D-LR
2.3 Bottom View
The bottom panel of the 8 10/100TX w/ X-Ring Managed Industrial Switch has one
terminal block connector for two (2) DC power inputs and one fault alarm.
Bottom Panel of the industrial switch
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
10
Page 19
Transition Networks SISPM1040-182D
2.4 LED Indicators
The diagnostic LEDs that provide real-time status information are located on the front
panel of the industrial switch. The following table provides the description of the LED
status and their meanings.
LED Color Status Meaning
On The switch unit is powered on
PWR
Green
Off No power
R.M.
Green
PWR1 Green
PWR2 Green
FAULT Red
Green
(Upper LED)
P9, P10 (RJ-
45)
On
The industrial switch is the master of the
X-Ring group
The industrial switch is not a ring master in
Off
the X-Ring group
On Power 1 is active
Off Power 1 is inactive
On Power 2 is active
Off Power 2 is inactive
On Power or port failure
Off No failures
On A network device is detected.
The port is transmitting or receiving packets
Blinking
from the TX device.
Off No device attached
Green
On 1000M
(Lower LED)
Off 10/100M
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 20
Transition Networks SISPM1040-182D-LR
On The SFP port is linking
Link/Active
(P9, P10
SFP)
Green
Blinks
The port is transmitting or receiving packets
from the TX device.
Off No device attached
On A network device is detected.
P1 ~ P8
FWD (P1 ~
P8)
Green
Amber
Green
Blinking
The port is transmitting or receiving packets
from the TX device.
Off No device attached
On
The port is operating in full-duplex mode.
Blinking Collision of Packets occurs.
The port is in half-duplex mode or no device
Off
is attached.
A powered device is connected utilizing
Green
Power over Ethernet on the port
No device is connected or power forwarding
Off
fails
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
12
Page 21
Transition Networks SISPM1040-182D
Chapter 3 Hardware Installation
This chapter describes how to physically install the 8 10/100TX w/ X-Ring Managed
Industrial Switch.
3.1 Installation Steps
1. Unpack the Industrial switch
2. Check if the DIN-Rail is screwed on the Industrial switch or not. If the DIN-Rail is not
screwed on the Industrial switch, please refer to DIN-Rail Mounting section for DIN-
Rail installation. If users want to wall mount the Industrial switch, please refer to Wall
Mount Plate Mounting section for wall mount plate installation.
3. Hang the Industrial switch on the DIN-Rail track or wall.
4. Power on the Industrial switch. Please refer to the Wiring the Power Inputs section
for information about how to wire power. The power LED on the Industrial switch will
light up. Please refer to the LED Indicators section.
5. Prepare the twisted-pair, straight through Category 5 cable for Ethernet connection.
6. Insert one side of RJ-45 cable (category 5) into the Industrial switch Ethernet port
(RJ-45 port) and another side of RJ-45 cable (category 5) to the network device’s
Ethernet port (RJ-45 port), ex: Switch PC or Server. The UTP port (RJ-45) LED on
the Industrial switch will light up when the cable is connected with the network device.
Please refer to the LED Indicators section.
[NOTE]
7. When all connections are set and LED lights all show normal, the installation is
Make sure that the connected network devices support MDI/MDI-X. If it does not
support, use the crossover category-5 cable.
complete.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 22
Transition Networks SISPM1040-182D-LR
3.2 DIN-Rail Mounting
The DIN-Rail is factory installed. If the DIN-Rail is not screwed on the industrial switch,
please see the following pictures. Follow the steps below to hang the industrial switch.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
14
Page 23
Transition Networks SISPM1040-182D
1. First, insert the top of DIN-Rail into the track.
2. Then, lightly push the DIN-Rail into the track.
3. Verify the DIN-Rail is tightened.
4. To remove the industrial switch from the track, reverse above steps.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 24
Transition Networks SISPM1040-182D
3.3 Wall Mount Plate Mounting
Follow the steps below to mount the industrial switch with wall mount plate.
1. Remove the DIN-Rail from the industrial switch; loose the screws to remove the DIN-
Rail.
2. Place the wall mount plate on the rear panel of the industrial switch.
3. Use the screws to screw the wall mount plate on the industrial switch.
4. Use the hook holes at the corners of the wall mount plate to hang the industrial
switch on the wall.
5. To remove the wall mount plate, reverse the above steps.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 25
Transition Networks SISPM1040-182D
3.4 Wiring the Power Inputs
Please follow the steps below to insert the power wire.
1. Insert AC or DC power wires into the contacts 1 and 2 for power 1, or 5 and 6 for
power 2.
2. Tighten the wire-clamp screws.
[NOTE]
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
The wire gauge should be in the range 12 ~ 24 AWG.
Page 26
Transition Networks SISPM1040-182D
3.5 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the picture
below shows. If configured the switch will detect power failure, or port link failure
(available for managed model) and then form an open circuit. The following illustration
shows an application example for wiring the fault alarm contacts.
Insert the wires into the fault alarm contacts
[NOTE]
The wire gauge for the terminal block should be in the range between 12 ~ 24
AWG.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 27
Transition Networks SISPM1040-182D
3.6 Cabling
Use four twisted-pair, Category 5e or above cabling for RJ-45 port connection. The
cable between the switch and the link partner (switch, hub, workstation, etc.) must
be less than 100 meters (328 ft.) long.
Fiber segment using single-mode connector type must use 9/125 μm single-mode
fiber cable. User can connect two devices in the distance up to 30km.
Fiber segment using multi-mode connector type must use 50 or 62.5/125 μm multi-
mode fiber cable. User can connect two devices up to 2km distances.
Gigabit Copper/SFP (mini-GBIC) combo port:
The Industrial switch has auto-detected Giga port—Gigabit Copper/SFP combo ports.
The Gigabit Copper (10/100/1000T) ports should use Category 5e or above UTP/STP
cable for the connection up to 1000Mbps. The small form-factor pluggable (SFP) is a
compact optical transceiver used in optical communications for both telecommunication
and data communications. The SFP slots supporting dual mode can switch the
connection speed between 100 and 1000Mbps. They are used for connecting to the
network segment with single or multi-mode fiber. Choose the appropriate SFP
transceiver to plug into the slots. Then use proper multi-mode or single-mode fiber
according to the transceiver. Fiber optic signals transmit at speeds up to 1000 Mbps and
are immune to electrical interference.
Note The SFP/Copper Combo port can’t both work at the same time. The SFP port
has higher priority than the copper port; if you insert the 1000M SFP
transceiver (connected to the remote device via fiber cable) into the SFP port,
the connection of the accompanying copper port link will down.
If you insert the 100M SFP transceiver into the SFP port even without a fiber
connection to the remote, the connection of the accompanying copper port will
link down immediately.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 28
Transition Networks SISPM1040-182D-LR
To connect the transceiver and LC cable, please follow the steps shown below:
First, insert the transceiver into the SFP module. Notice that the triangle mark is the
bottom of the module.
Transceiver to the SFP module
Transceiver Inserted
Second, insert the fiber cable of LC connector into the transceiver.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
20
Page 29
Transition Networks SISPM1040-182D-LR
LC connector to the transceiver
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
21
Page 30
Transition Networks SISPM1040-182D-LR
To remove the LC connector from the transceiver, please follow the steps shown below:
First, press the upper side of the LC connector to release from the transceiver and pull it
out.
Remove LC connector
Second, push down the metal loop and pull the transceiver out by the plastic handle.
Pull out from the transceiver
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
22
Page 31
Transition Networks SISPM1040-182D
Chapter 4 Network Application
This chapter illustrates some example applications. Below is a typical industrial switch
application:
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 32
Transition Networks SISPM1040-182D-LR
The illustration below shows an example power over Ethernet application.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
24
Page 33
Transition Networks SISPM1040-182D
4.1 X-Ring Application
The industrial switch supports the X-Ring protocol that can help the network recover
from connection failure within 20ms or less, and make the network system more reliable.
The X-Ring algorithm is similar to spanning tree protocol (STP) algorithm but its recovery
time is faster than STP. The following figure is a sample X-Ring application.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 34
Transition Networks SISPM1040-182D
4.2 Coupling Ring Application
A network may have more than one X-Ring group. The coupling ring function can
connect each X-Ring for redundant backup. It can ensure transmissions between two
ring groups do not fail. The following figure illustrates a coupling ring application.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 35
Transition Networks SISPM1040-182D
4.3 Dual Homing Application
The Dual Homing function prevents lost connection between an X-Ring group and an
upper level/core switch. Assign two ports to be the Dual Homing ports in the X-Ring
group. The Dual Homing function only works when the X-Ring function is active. Each X-
Ring group only has one Dual Homing port.
[NOTE] In Dual Homing application architecture, the upper level switches need to
enable the Rapid Spanning Tree protocol.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 36
Transition Networks SISPM1040-182D
4.4 Dual Ring Application
Dual ring is an advanced function that supports backup connection to ensure redundant
transmission. If the connection fails, the system will recover from fwithin 20 milliseconds.
Apart from that, Dual Ring only needs one unit (and only the one located in the middle)
to be configured as the Ring Master switch to deploy the dual ring.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 37
Transition Networks SISPM1040-182D
Chapter 5 Console Management
5.1 Connecting to the Console Port
The supplied cable has an RS-232 connector on one end and an RJ-45 connector on
the other end. Attach the RS-232 connector to a PC or terminal and the other end of
RJ-45 connector to the console port of the switch. The connected terminal or PC must
support the terminal emulation program.
5.2 Pin Assignment
DB9 Connector RJ-45 Connector
NC 1 Orange/White
2 2 Orange
3 3 Green/White
NC 4 Blue
5 5 Blue/White
NC 6 Green
NC 7 Brown/White
NC 8 Brown
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 38
Transition Networks SISPM1040-182D-LR
5.3 Login in the Console Interface
When the connection between the Switch and the PC is ready, turn on the PC and run a
terminal emulation program or Hyper Terminal and configure its communication
parameters to match the following default characteristics of the console port:
Baud Rate: 9600 bps
Data Bits: 8
Parity: none
Stop Bit: 1
Flow control: None
The settings of communication parameters
After changing the parameter settings, click ‘OK’. When the blank screen shows up,
press the Enter key to have the login prompt appear. Type ‘root’ (default value) for both
User name and Password (use Enter key to tab), then press Enter and the Main Menu
of console management appears. Please see below figure for login screen.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
30
Page 39
Transition Networks SISPM1040-182D-LR
Console login interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
31
Page 40
Transition Networks SISPM1040-182D
5.4 CLI Management
The switch supports console management—CLI commands. After you log in to the
system, you will see a command prompt. To enter CLI management interface, type
enable”.
CLI command interface
The following table lists the CLI commands and their description.
5.5 Commands Level
Modes
User EXEC
Privileged
EXEC
Access
Method
Begin a
session with
your switch.
Enter the
enable
command
while in User
Prompt
switch>
switch#
Exit
Method
Enter
logout or
quit.
Enter
disable to
exit.
About This Mode1
The user commands
available at the user
level are a subset of
those available at the
privileged level.
Use this mode to
• Perform basic tests.
• Display system
information.
The privileged
command is the
advanced mode.
Use this mode to
• Display advanced
EXEC mode.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
function status
• Save configuration
Page 41
Transition Networks SISPM1040-182D-LR
Global
Configuration
VLAN
database
Enter the
configure
command
while in
privileged
EXEC mode.
Enter the
vlan
database
command
while in
privileged
EXEC mode.
Enter the
interface of
switch
(config)#
switch
(vlan)#
To exit to
privileged
EXEC
mode, enter
exit or end
To exit to
user EXEC
mode, enter
exit.
To exit to
global
Use this mode to
configure those
parameters that are
going to be applied to
your switch.
Use this mode to
configure VLAN-
specific parameters.
Interface
configuration
fast Ethernet
command
(with a
specific
interface)
while in global
configuration
mode.
switch
(config-if)#
configuratio
n mode,
enter exit.
To exit to
privileged
EXEC
mode, enter
exit or end.
Use this mode to
configure parameters
for the switch and
Ethernet ports.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
33
Page 42
Transition Networks SISPM1040-182D
Chapter 6 Web-Based Management
This section introduces the configuration and functions of the Web-Based management.
6.1 About Web-based Management
There is an embedded HTML web server residing in flash memory in the switch. This
offers advanced management features and allows users to manage the switch from
anywhere on the network through a standard web browser such as Microsoft Internet
Explorer.
The Web-Based Management supports Internet Explorer 6.0 or later version. It
incorporates Java Applets for reducing network bandwidth consumption, enhancing
access speed and presenting an easy viewing screen.
6.2 Preparing for Web Management
Before using web management, install the industrial switch on the network and make
sure that at least one of the PCs on the network can connect with the industrial switch
through the web browser. The industrial switch default IP Address, Subnet Mask,
Gateway, username and password are the following:
IP Address: 192.168.1.77
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.254
User Name: root
Password: root
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 43
Transition Networks SISPM1040-182D-LR
6.3 System Login
1. Launch the Internet Explorer on the PC
2. Key in “http:// “+” the IP address of the switch”, and then Press “Enter”.
3. The login screen will appear right after
4. Key in the user name and password. The default user name and password are
root’.
5. Press Enter or click the OK button. Then the home screen of the Web-based
management appears.
Login screen
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
35
Page 44
Transition Networks SISPM1040-182D-LR
6.4 System Information
Users can assign the system name, description, location and contact personnel to
identify the switch. The version table below is a read-only field to show the basic
information of the switch.
System Name: Assign the system name of the switch (The maximum length is 64
bytes)
System Description: Describes the switch.
System Location: Assign the switch physical location (The maximum length is 64
bytes).
System Contact: Enter the name of contact person or organization.
Firmware Version: Displays the switch’s firmware version
Kernel Version: Displays the kernel software version
MAC Address: Displays the unique hardware address assigned by manufacturer
(default)
And then, click
Apply
.
Switch settings interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
36
Page 45
Transition Networks SISPM1040-182D
6.5 IP Configuration
The switch is a network device which needs to be assigned an IP address for being
identified on the network. Users have to decide a means of assigning IP address to the
switch.
DHCP Client: Enable or disable the DHCP client function. When DHCP client
function is enabled, the switch will be assigned an IP address from the network
DHCP server. The default IP address will be replaced by the assigned IP address
on DHCP server. After the user clicks Apply, a popup dialog shows up to inform the
user that when the DHCP client is enabled, the current IP will lose and user should
find the new IP on the DHCP server.
IP Address: Assign the IP address that the network is using. If DHCP client function
is enabled, this switch is configured as a DHCP client. The network DHCP server
will assign the IP address to the switch and display it in this column. The default IP
is 192.168.1.77 or the user has to assign an IP address manually when DHCP
Client is disabled.
Subnet Mask: Assign the subnet mask to the IP address. If DHCP client function is
disabled, the user has to assign the subnet mask in this column field.
Gateway: Assign the network gateway for the switch. If DHCP client function is
disabled, the user has to assign the gateway in this column field. The default
gateway is 192.168.1.254.
DNS1: Assign the primary DNS IP address.
DNS2: Assign the secondary DNS IP address.
And then, click
Apply
.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 46
Transition Networks SISPM1040-182D-LR
IP configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
38
Page 47
Transition Networks SISPM1040-182D
6.6 DHCP Server
DHCP is the abbreviation of Dynamic Host Configuration Protocol that is a protocol for
assigning dynamic IP addresses to devices on a network. With dynamic addressing, a
device can have a different IP address every time it connects to the network. In some
systems, the device's IP address can even change while it is still connected. DHCP
also supports a mix of static and dynamic IP addresses. Dynamic addressing
simplifies network administration because the software keeps track of IP addresses
rather than requiring an administrator to manage the task. This means that a new
computer can be added to a network without the hassle of manually assigning it a
unique IP address.
The system provides the DHCP server function. Having enabled the DHCP server
function, the switch system will be configured as a DHCP server.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 48
Transition Networks SISPM1040-182D
6.6.1 System configuration
DHCP Server: Enable or Disable the DHCP Server function. Enable—the switch
will be the DHCP server on your local network.
Low IP Address: Type in an IP address. Low IP address is the beginning of the
dynamic IP range. For example, dynamic IP is in the range between
192.168.1.100 ~ 192.168.1.200. In contrast, 192.168.1.100 is the Low IP address.
High IP Address: Type in an IP address. High IP address is the end of the
dynamic IP range. For example, dynamic IP is in the range between
192.168.1.100 ~ 192.168.1.200. In contrast, 192.168.1.200 is the High IP
address.
Subnet Mask: Type in the subnet mask of the IP configuration.
Gateway: Type in the IP address of the gateway in your network.
DNS: Type in the Domain Name Server IP Address in your network.
Lease Time (sec): It is the time period that system will reset the dynamic IP
assignment to ensure the dynamic IP will not remain occupied for a long time or
the server doesn’t know that the dynamic IP is idle.
And then, click
Apply
.
DHCP Server Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 49
Transition Networks SISPM1040-182D
6.6.2 Client Entries
When the DHCP server function is enabled, the system will collect the DHCP client
information including the assigned IP address, the MAC address of the client device,
the IP assigning type, status and lease time.
DHCP Client Entries interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 50
Transition Networks SISPM1040-182D
6.6.3 Port and IP Bindings
Assign the dynamic IP address bound with the port to the connected client. The user is
allowed to fill each port column with one particular IP address. When the device is
connecting to the port and asks for IP assigning, the system will assign the IP address
bound with the port.
Port and IP Bindings interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 51
Transition Networks SISPM1040-182D
6.7 TFTP
TFTP allows the user to update the switch firmware via the Trivial File Transfer
Protocol (TFTP) server. Before updating, make sure the TFTP server is ready and the
firmware image is located on the TFTP server.
6.7.1 Update Firmware
TFTP Server IP Address: Type in your TFTP server IP.
Firmware File Name: Type in the name of the firmware image file to be updated.
Click
Apply
.
Update Firmware interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 52
Transition Networks SISPM1040-182D
6.7.2 Restore Configuration
You can restore a previous backup configuration from the TFTP server to recover the
settings. Before doing so, you must locate the image file on the TFTP server.
TFTP Server IP Address: Type in the TFTP server IP.
Restore File Name: Type in the correct file name for restoring configuration.
Click
Apply
.
Restore Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 53
Transition Networks SISPM1040-182D
6.7.3 Backup Configuration
You can back up the current configuration from flash ROM to the TFTP server for the
purpose of recovering the configuration later. It helps you save time.
TFTP Server IP Address: Type in the TFTP server IP.
Backup File Name: Type in the file name.
Click
Apply
.
Backup Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 54
Transition Networks SISPM1040-182D
6.8 System Event Log
This page allows the user to decide whether to send the system event log, and select the
mode which the system event log will be sent to client only, server only, or both client
and server. What kind of event log will be issued to the client/server depends on the
selection on the Event Configuration tab. There are five types of events—Device Cold
Start, Device Warm Start, Authentication Failure, X-Ring Topology Change, and Port
Event—available to be issued as the event log.
6.8.1 Syslog Configuration
Syslog Client Mode: Select the system log mode—Client Only, Server Only, or
Both. ‘Client Only’ means the system event log will only be sent to this interface of the
switch. ‘Server Only’ means the system log will only be sent to the remote system
log server with its IP assigned. If the mode is set to ‘Both’, the system event log will be
sent to the remote server and this interface.
System Log Server IP Address: When the ‘Syslog Mode’ item is set as Server
Only/Both, the user has to assign the system log server IP address to which the log
will be sent.
Click
Click
Make sure the selected mode is correct, and click
Reload
Clear
to refresh the event log displaying area.
to clear all the current event logs.
Apply
to have the setting take
effect.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 55
Transition Networks SISPM1040-182D-LR
Syslog Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
47
Page 56
Transition Networks SISPM1040-182D
6.8.2 System Event Log—SMTP Configuration
Simple Mail Transfer Protocol (SMTP) is the standard for email transmissions across
the network. You can configure the SMTP server IP, mail subject, sender, mail
account, password, and the recipient email addresses which the e-mail alert will send
to. There are also five types of event—Device Cold Start, Device Warm Start,
Authentication Failure, X-Ring Topology Change, and Port Event—available to be
issued as the e-mail alert. Besides, this function provides the authentication
mechanism including an authentication step through which the client effectively logs in
to the SMTP server during the process of sending e-mail alert.
Email Alert: With this function being enabled, the user is allowed to configure the
detail settings for sending the e-mail alert to the SMTP server when the events
occur.
SMTP Server IP: Assign the mail server IP address (when Email Alert is
enabled, this function will then be available).
Sender: Type in an alias of the switch in complete email address format, e.g.
switch101@123.com
, to identify where the e-mail alert comes from.
Authentication: Having checked this box, the mail account, password and
confirm password column fields will then show up. Configure the email account
and password for authentication when this switch logs in to the SMTP server.
Mail Account: Set up the email account, e.g. johnadmin
, to receive the email
alert. It must be an existing email account on the mail server.
Password: Type in the password for the email account.
Confirm Password: Reconfirm the password.
Rcpt e-mail Address 1 ~ 6: You can also fill each of the column fields with up to
6 e-mail accounts to receive the email alert.
Click
Apply
to have the configuration take effect.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 57
Transition Networks SISPM1040-182D-LR
SMTP Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
49
Page 58
Transition Networks SISPM1040-182D
6.8.3 System Event Log—Event Configuration
Having ticked the
Syslog/SMTP
checkboxes, the event log/email alert will be sent to the
system log server and the SMTP server respectively. Also, Port event log/alert (link up,
link down, and both) can be sent to the system log server/SMTP server respectively by
setting the trigger condition.
System event selection: There are 4 event types—Device Cold Start, Device
Warm Start, Authentication Failure, and X-ring Topology Change. The checkboxes
are not available for ticking unless the Syslog Client Mode on the Syslog
Configuration tab and the E-mail Alert on the SMTP Configuration tab are enabled
first.
¾ Device cold start: When the device executes cold start action, the system will
issue the event log/email alert to the system log/SMTP server respectively.
¾ Device warm start: When the device executes warm start, the system will
issue the event log/email alert to the system log/SMTP server respectively.
¾ Authentication Failure: When the SNMP authentication fails, the system will
issue the event log/email alert to the system log/SMTP server respectively.
¾ X-ring topology change: When the X-ring topology has changed, the system
will issue the event log/email alert to the system log/SMTP server respectively.
Port event selection: Also, before the drop-down menu items are available, the
Syslog Client Mode selection item on the Syslog Configuration tab and the E-mail
Alert selection item on the SMTP Configuration tab must be enabled first. Those
drop-down menu items have 3 selections—Link UP, Link Down, and Link UP &
Link Down. Disable means no event will be sent to the system log/SMTP server.
¾ Link UP: The system will only issue a log message when the link-up event of
the port occurs.
¾ Link Down: The system will only issue a log message when the link-down
event of port occurs.
¾ Link UP & Link Down: The system will issue a log message at the time when
port connection is link-up and link-down.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 59
Transition Networks SISPM1040-182D-LR
Event Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
51
Page 60
Transition Networks SISPM1040-182D
6.9 Fault Relay Alarm
The Fault Relay Alarm function provides Power Failure and Port Link Down/Broken
detection. With both power input 1 and power input 2 installed and the check boxes of
power 1/power 2 ticked, the FAULT LED indicator will then light up if either power failure
occurs. As for the Port Link Down/Broken detection, the FAULT LED indicator will light
up when the port failure occurs; the check box beside the port must be ticked first.
Please refer to the section, ‘
Wiring the Fault Alarm Contact
’, for the failure detection.
Power Failure: Tick the check box to enable the function of lighting up the FAULT
LED on the panel when power fails.
Port Link Down/Broken: Tick the check box to enable the function of lighting up
FAULT LED on the panel when Ports’ states are link down or broken.
Fault Relay Alarm interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 61
Transition Networks SISPM1040-182D
6.10 SNTP Configuration
SNTP (Simple Network Time Protocol) is a simplified version of NTP which is an Internet
protocol used to synchronize the clocks of computers to some time reference. Because
time usually just advances, the time on different node stations will be different. With the
communicating programs running on those devices, it would cause time to jump forward
and back, a non-desirable effect. Therefore, the switch provides comprehensive
mechanisms to access national time and frequency dissemination services, organize the
time-synchronization subnet and the local clock in each participating subnet peer.
Daylight saving time (DST) is the convention of advancing clocks so that afternoons
have more daylight and mornings have less. Typically clocks are adjusted forward one
hour near the start of spring and are adjusted backward in autumn.
SNTP Client: Enable/disable SNTP function to get the time from the SNTP server.
Daylight Saving Time: This is used as a control switch to enable/disable daylight
saving period and daylight saving offset. Users can configure Daylight Saving
Period and Daylight Saving Offset in a certain period time and offset time while
there is no need to enable daylight saving function. Afterwards, users can just
enable this without assigning Daylight Saving Period and Daylight Saving Offset
again.
UTC Timezone: Universal Time, Coordinated. Set the switch location time zone.
The following table lists the different location time zone for your reference.
Local Time Zone
Conversion from UTC Time at 12:00 UTC
November Time Zone - 1 hour 11am
Oscar Time Zone -2 hours 10 am
ADT - Atlantic Daylight -3 hours 9 am
AST - Atlantic Standard
-4 hours 8 am
EDT - Eastern Daylight
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 62
Transition Networks SISPM1040-182D-LR
EST - Eastern Standard
-5 hours 7 am
CDT - Central Daylight
CST - Central Standard
-6 hours 6 am
MDT - Mountain Daylight
MST - Mountain
Standard
-7 hours 5 am
PDT - Pacific Daylight
PST - Pacific Standard
-8 hours 4 am
ADT - Alaskan Daylight
ALA - Alaskan Standard -9 hours 3 am
HAW - Hawaiian
-10 hours 2 am
Standard
Nome, Alaska -11 hours 1 am
CET - Central European
FWT - French Winter
MET - Middle European
+1 hour 1 pm
MEWT - Middle
European Winter
SWT - Swedish Winter
EET - Eastern
+2 hours 2 pm
European, USSR Zone 1
BT - Baghdad, USSR
+3 hours 3 pm
Zone 2
ZP4 - USSR Zone 3 +4 hours 4 pm
ZP5 - USSR Zone 4 +5 hours 5 pm
ZP6 - USSR Zone 5 +6 hours 6 pm
WAST - West Australian
+7 hours 7 pm
Standard
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
54
Page 63
Transition Networks SISPM1040-182D-LR
CCT - China Coast,
+8 hours 8 pm
USSR Zone 7
JST - Japan Standard,
+9 hours 9 pm
USSR Zone 8
EAST - East Australian
Standard GST
+10 hours 10 pm
Guam Standard, USSR
Zone 9
IDLE - International Date
Line
NZST - New Zealand
+12 hours Midnight
Standard
NZT - New Zealand
SNTP Sever URL: Set the SNTP server IP address. You can assign a local network
time server IP address or an internet time server IP address.
Switch Timer: When the switch has successfully connected to the SNTP server
whose IP address was assigned in the column field of SNTP Server URL, the
current coordinated time is displayed here.
Daylight Saving Period: Set up the Daylight Saving beginning date/time and
Daylight Saving ending date/time. Please key in the value in the format of
‘YYYYMMDD’ and ‘HH:MM’ (leave a space between ‘YYYYMMDD’ and ‘HH:MM’).
¾ YYYYMMDD: an eight-digit year/month/day specification.
¾ HH:MM: a five-digit (including a colon mark) hour/minute specification.
For example, key in ‘20070701 02:00’ and ‘20071104 02:04’ in the two column
fields respectively to represent that DST begins at 2:00 a.m. on March 11, 2007
and ends at 2:00 a.m. on November 4, 2007.
Daylight Saving Offset (mins): For non-US and European countries, specify the
amount of time for day light savings. Please key in the valid figure in the range of
minute between 0 and 720, which means you can set the offset up to 12 hours.
Click
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Apply
to have the configuration take effect.
55
Page 64
Transition Networks SISPM1040-182D-LR
SNTP Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
56
Page 65
Transition Networks SISPM1040-182D
6.11 IP Security
IP security allows the user to assign 10 specific IP addresses that have permission to
manage the switch through the http and telnet services. The purpose of providing limited
IP addresses permission is to allow only the authorized personnel/device access to
management tasks on the switch.
IP Security Mode: Having set this selection item in the Enable mode, the Enable
HTTP Server, Enable Telnet Server checkboxes and the ten security IP column
fields will then be available. If not, those items will appear in grey.
Enable HTTP Server: Having ticked this checkbox, the devices whose IP
addresses match any one of the ten IP addresses in the Security IP1 ~ IP10 table
will be given the permission to access this switch via HTTP service.
Enable Telnet Server: Having ticked this checkbox, the devices whose IP
addresses match any one of the ten IP addresses in the Security IP1 ~ IP10 table
will be given the permission to access this switch via telnet service.
Security IP 1 ~ 10: The system allows the user to assign up to 10 specific IP
addresses for access security. Only these 10 IP addresses can access and manage
the switch through the HTTP/Telnet service once IP Security Mode is enabled.
And then, click
[NOTE]
Remember to execute the “Save Configuration” action, otherwise the new
Apply
to have the configuration take effect.
configuration will be lost when the switch powers off.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 66
Transition Networks SISPM1040-182D-LR
IP Security interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
58
Page 67
Transition Networks SISPM1040-182D
6.12 User Authentication
Change web management login user name and password for the management security
issue.
User name: Type in the new user name (The default is ‘root’)
Password: Type in the new password (The default is ‘root’)
Confirm password: Re-type the new password
And then, click
Apply
User Authentication interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 68
Transition Networks SISPM1040-182D
6.13 Port Statistics
The following chart provides the current statistic information which displays the real-time
packet transfer status for each port. The user might use the information to plan and
implement the network, or check and find problems when collisions or heavy traffic
occurs.
Port: The port number.
Type: Displays the current speed of connection to the port.
Link: The status of linking—‘Up’ or ‘Down’.
State: It’s set by Port Control. When the state is disabled, the port will not transmit
or receive any packet.
Tx Good Packet: The counts of transmitting good packets via this port.
Tx Bad Packet: The counts of transmitting bad packets (including undersize [less
than 64 octets], oversize, CRC Align errors, fragments and jabbers packets) via this
port.
Rx Good Packet: The counts of receiving good packets via this port.
Rx Bad Packet: The counts of receiving good packets (including undersize [less
than 64 octets], oversize, CRC error, fragments and jabbers) via this port.
Tx Abort Packet: The aborted packet while transmitting.
Packet Collision: The counts of collision packet.
Packet Dropped: The counts of dropped packet.
Rx Bcast Packet: The counts of broadcast packet.
Rx Mcast Packet: The counts of multicast packet.
Click
Clear
button to clean all counts.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 69
Transition Networks SISPM1040-182D-LR
Port Statistics interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
61
Page 70
Transition Networks SISPM1040-182D
6.14 Port Control
In Port control you can configure the settings of each port to control the connection
parameters, and the status of each port is listed beneath.
Port: Use the scroll bar and click on the port number to choose the port to be
configured.
State: Current port state. The port can be set to disable or enable mode. If the port
state is set as ‘Disable’, it will not receive or transmit any packet.
Negotiation: Auto and Force. Being set as Auto, the speed and duplex mode are
negotiated automatically. When you set it as Force, you have to set the speed and
duplex mode manually.
Speed: It is available for selecting when the Negotiation column is set as Force.
When the Negotiation column is set as Auto, this column is read-only.
Duplex: It is available for selecting when the Negotiation column is set as Force.
When the Negotiation column is set as Auto, this column is read-only.
Flow Control: Whether or not the receiving node sends feedback to the sending
node is determined by this item. When enabled, once the device exceeds the input
data rate of another device, the receiving device will send a PAUSE frame which
halts the transmission of the sender for a specified period of time. When disabled,
the receiving device will drop the packet if too much to process.
Security: When the Security selection is set as ‘On’, any access from the device
which connects to this port will be blocked unless the MAC address of the device is
included in the static MAC address table. See the segment of MAC Address
Table—Static MAC Addresses.
Click
Apply
to have the configuration take effect.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 71
Transition Networks SISPM1040-182D-LR
Port Control interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
63
Page 72
Transition Networks SISPM1040-182D
6.15 Port Trunk
Port trunking is the combination of several ports or network cables to expand the
connection speed beyond the limits of any one single port or network cable. Link
Aggregation Control Protocol (LACP), which is a protocol running on layer 2, provides
a standardized means in accordance with IEEE 802.3ad to bundle several physical
ports together to form a single logical channel. All the ports within the logical channel
or so-called logical aggregator work at the same connection speed and LACP
operation requires full-duplex mode.
6.15.1 Aggregator setting
System Priority: A value which is used to identify the active LACP. The switch
with the lowest value has the highest priority and is selected as the active LACP
peer of the trunk group.
Group ID:
the trunk group.
LACP: When enabled, the trunk group is using LACP. A port which joins an
LACP trunk group has to make an agreement with its member ports first. Please
notice that a trunk group, including member ports split between two switches, has
to enable the LACP function of the two switches. When disabled, the trunk group
is a static trunk group. The advantage of having the LACP disabled is that a port
joins the trunk group without any handshaking with its member ports; but member
ports won’t know that they should be aggregated together to form a logic trunk
group.
Work ports: This column field allows the user to type in the total number of
active port up to four. With LACP static trunk group, e.g. you assign four ports
There are 13 trunk groups to be selected. Assign the "
Group ID
" to
to be the members of a trunk group whose work ports column field is set as two;
the exceed ports are standby/redundant ports and can be aggregated if working
ports fail. If it is a static trunk group (non-LACP), the number of work ports must
equal the total number of group member ports.
Select the ports to join the trunk group. The system allows a maximum of four
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 73
Transition Networks SISPM1040-182D-LR
Add
ports to be aggregated in a trunk group. Click
and the ports focused in
the right side will be shifted to the left side. To remove unwanted ports, select the
ports and click
Remove
.
When LACP enabled, you can configure LACP Active/Passive status for each
port on the State Activity tab.
Apply
Click
Use
Delet e
.
to delete Trunk Group. Select the Group ID and click
Delet e
.
Port Trunk—Aggregator Setting interface (four ports are added to the left field with LACP enabled)
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
65
Page 74
Transition Networks SISPM1040-182D
6.15.2 Aggregator Information
z LACP disabled
Having set up the aggregator setting with LACP disabled, you will see the local static
trunk group information on the tab of Aggregator Information.
Assigning 2 ports to a trunk group with LACP disabled
Static Trunking Group information
Group Key: This is a read-only column field that displays the trunk group ID.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 75
Transition Networks SISPM1040-182D-LR
Port Member: This is a read-only column field that displays the members of this
static trunk group.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
67
Page 76
Transition Networks SISPM1040-182D
z LACP enabled
Having set up the aggregator setting with LACP enabled, you will see the trunking
group information between two switches on the tab of Aggregator Information.
Switch 1 configuration
1. Set System Priority of the trunk group. The default is 1.
2. Select a trunk group ID by pull down the drop-down menu bar.
3. Enable LACP.
4. Include the member ports by clicking the Add button after selecting the port
number and the column field of Work Ports changes automatically.
Switch 1 configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 77
Transition Networks SISPM1040-182D-LR
Aggregation Information of Switch 1
5. Click on the tab of Aggregator Information to check the trunked group
information as the illustration shown above after the two switches configured.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
69
Page 78
Transition Networks SISPM1040-182D
Switch 2 configuration
Switch 2 configuration interface
1. Set System Priority of the trunk group. The default is 1.
2. Select a trunk group ID by pull down the drop-down menu bar.
3. Enable LACP.
4. Include the member ports by clicking the Add button after selecting the port
number and the column field of Work Ports changes automatically.
Aggregation Information of Switch 2
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 79
Transition Networks SISPM1040-182D-LR
5. Click on the tab of Aggregator Information to check the trunked group
information as the illustration shown above after the two switches configured.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
71
Page 80
Transition Networks SISPM1040-182D
6.15.3 State Activity
Having set up the LACP aggregator on the tab of Aggregator Setting, you can configure
the state activity for the members of the LACP trunk group. You can tick or cancel the
checkbox beside the state label. When you remove the tick mark of the port and click
Apply
, the port state activity will change to
Passive
.
Active: The port automatically sends LACP protocol packets.
Passive: The port does not automatically send LACP protocol packets, and
responds only if it receives LACP protocol packets from the opposite device.
[NOTE]
A link having two passive LACP nodes will not perform dynamic LACP
trunk because both ports are waiting for an LACP protocol packet from
the opposite device.
State Activity of Switch 1
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 81
Transition Networks SISPM1040-182D-LR
State Activity of Switch 2
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
73
Page 82
Transition Networks SISPM1040-182D
6.16 Port Mirroring
Port mirroring is a method for monitoring traffic in switched networks. Traffic through
ports can be monitored by one specific port, which means traffic that goes in or out
monitored (source) ports will be duplicated into mirror (destination) port.
Destination Port: There is only one port can be selected to be destination (mirror)
port for monitoring both RX and TX traffic which come from source port. Or, use one
of two ports for monitoring RX traffic only and the other one for TX traffic only. User
can connect mirror port to LAN analyzer or Netxray.
Source Port: The ports that user wants to monitor. All monitored port traffic will be
copied to mirror (destination) port. User can select multiple source ports by checking
the RX or TX check boxes to be monitored.
And then, click
Apply
button.
Port Trunk – Port Mirroring interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 83
Transition Networks SISPM1040-182D
6.17 Rate Limiting
You can set up every port’s bandwidth rate and frame limitation type.
Ingress Limit Frame type: select the frame type that wants to filter. There are four
frame types for selecting:
¾ All
¾ Broadcast/Multicast/Flooded Unicast
¾ Broadcast/Multicast
¾ Broadcast only
Broadcast/Multicast/Flooded Unicast, Broadcast/Multicast and Bbroadcast
only types are only for ingress frames. The egress rate only supports All type.
Rate Limiting interface
All the ports support port ingress and egress rate control. For example, assume port
1 is 10Mbps, users can set it’s effective egress rate at 1Mbps, ingress rate at
500Kbps. The switch performs the ingress rate by packet counter to meet the
specified rate
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 84
Transition Networks SISPM1040-182D-LR
¾ Ingress: Enter the port effective ingress rate (The default value is “0”).
¾ Egress: Enter the port effective egress rate (The default value is “0”).
And then, click
Apply
to apply the settings
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
76
Page 85
Transition Networks SISPM1040-182D
6.18 VLAN configuration
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain,
which allows you to isolate network traffic. Only the members of the same VLAN will
receive traffic from those of the same VLAN. Basically, creating a VLAN on a switch is
the logical equivalent of reconnecting a group of network devices to another Layer 2
switch. However, all the network devices are still plugged into the same switch
physically.
This switch supports Port-based and 802.1Q (tagged-based) VLAN. The default
configuration of VLAN operation mode is “Disable”.
VLAN Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 86
Transition Networks SISPM1040-182D
6.18.1 Port-based VLAN
A port-based VLAN basically consists of its members—ports, which means the VLAN
is created by grouping the selected ports. This method provides convenience for
users to configure a simple VLAN easily without complicated steps. Packets can go
among only members of the same VLAN group. Note all unselected ports are treated
as belonging to another single VLAN. If the port-based VLAN is enabled, VLAN-
tagging is ignored. The port-based VLAN function allows the user to create separate
VLANs to limit unnecessary packet flooding; however, for the purpose of sharing
resource, a single port called a common port can belong to different VLANs; all the
member devices (ports) in different VLANs have permission to access the common
port while they still cannot communicate with each other in different VLANs.
VLAN – Port Based interface
Pull down the selection item and focus on
the VLAN Operation Mode to
Click
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Add
to add a new VLAN group (maximum VLAN groups is 64).
Port Based
Port Based
mode.
then press
Apply
to set
Page 87
Transition Networks SISPM1040-182D-LR
VLAN—Port Based Add interface
Enter the group name and VLAN ID. Add the selected port number into the right
field to group these members to be a VLAN group, or remove any of them listed
in the right field from the VLAN.
And then, click
Apply
to have the configuration take effect.
You will see the VLAN list displays.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
79
Page 88
Transition Networks SISPM1040-182D-LR
Use
Use
Delet e
Edit
existing VLAN group.
[NOTE]
Remember to execute the “Save Configuration” action, otherwise the new
configuration will be lost when the switch power off.
VLAN—Port Based Edit/Delete interface
to delete the VLAN.
to modify group name, VLAN ID, or add/remove the members of the
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
80
Page 89
Transition Networks SISPM1040-182D
6.18.2 802.1Q VLAN
Virtual Local Area Network (VLAN) can be implemented on the switch to logically
create different broadcast domains.
When the 802.1Q VLAN function is enabled, all ports on the switch belong to default
VLAN of VID 1, which means they logically are regarded as members of the same
broadcast domain. The valid VLAN ID is in the range of number between 1 and 4094.
The number of VLAN groups is up to 256, including the default VLAN that cannot be
deleted.
Each member port of 802.1Q is on either an Access Link (VLAN-tagged) or a Trunk
Link (no VLAN-tagged). All frames on an Access Link carry no VLAN identification.
Conversely, all frames on a Trunk Link are VLAN-tagged. Additionally, there is the
third mode—Hybrid. A Hybrid Link can carry both VLAN-tagged frames and untagged
frames. A single port is supposed to belong to one VLAN group, except it is on a
Trunk/Hybrid Link.
The technique of 802.1Q tagging inserts a 4-byte tag, including VLAN ID of the
destination port—PVID, in the frame. With the combination of Access/Trunk/Hybrid
Links, communication across switches can send the packet through tagged and
untagged ports.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 90
Transition Networks SISPM1040-182D
802.1Q Configuration
Pull down the selection item and focus on
VLAN Operation Mode in
802.1Q
mode.
802.1Q,
then press
Apply
to set the
Enable GVRP Protocol: GVRP (GARP VLAN Registration Protocol) is a protocol
that facilitates control of virtual local area networks (VLANs) within a larger network.
GVRP conforms to the IEEE 802.1Q specification, which defines a method of
tagging frames with VLAN configuration data. This allows network devices to
dynamically exchange VLAN configuration information with other devices. For
example, having enabled GVRP on two switches, they are able to automatically
exchange the information of their VLAN database. Therefore, the user doesn’t need
to manually configure whether the link is trunk or hybrid, the packets belonging to
the same VLAN can communicate across switches. Tick this checkbox to enable
GVRP protocol. This checkbox is available while the VLAN Operation Mode is in
802.1Q mode.
Management VLAN ID: Only the VLAN members whose Untagged VID (PVID)
equals the value in this column will have permission to access the switch. The
default value is ‘0’ that means this is not enabled (all members in different VLANs
can access this switch).
Select the port you want to configure.
Link Type: There are 3 types of link type.
¾ Access Link: A segment which provides the link path for one or more stations
to the VLAN-aware device. An Access Port (untagged port), connected to the
access link, has an untagged VID (also called PVID). After an untagged frame
gets into the access port, the switch will insert a four-byte tag in the frame. The
contents of the last 12-bit of the tag is untagged VID. When this frame is sent
out through any of the access port of the same PVID, the switch will remove the
tag from the frame to recover it to what it was. Those ports of the same
untagged VID are regarded as the same VLAN group members.
Note: Because the access port doesn’t have an understanding of tagged frame, the
column field of Tagged VID is not available.
¾ Trunk Link: A segment which provides the link path for one or more VLAN-
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 91
Transition Networks SISPM1040-182D-LR
aware devices (switches). A Trunk Port, connected to the trunk link, has an
understanding of tagged frame, which is used for the communication among
VLANs across switches. Which frames of the specified VIDs will be forwarded
depends on the values filled in the Tagged VID column field. Please insert a
comma between two VIDs.
Note:
1. A trunk port doesn’t insert tag into an untagged frame, and therefore the untagged
VID column field is not available.
2. It’s not necessary to type ‘1’ in the tagged VID. The trunk port will forward the frames
of VLAN 1.
3. The trunk port has to be connected to a trunk/hybrid port of the other switch. Both the
tagged VID of the two ports have to be the same.
¾ Hybrid Link: A segment which consists of Access and Trunk links. The hybrid
port has both the features of access and trunk ports. A hybrid port has a PVID
belonging to a particular VLAN, and it also forwards the specified tagged-
frames for the purpose of VLAN communication across switches.
Note:
1. It’s not necessary to type ‘1’ in the tagged VID. The hybrid port will forward the
frames of VLAN 1.
2. The trunk port has to be connected to a trunk/hybrid port of the other switch. Both
the tagged VID of the two ports have to be the same.
Untagged VID: This column field is available when Link Type is set as Access Link
and Hybrid Link. Assign a number in the range between 1 an 4094.
Tagged VID:
This column field is available when Link Type is set as Trunk Link and
Hybrid Link. Assign a number in the range between 1 an 4094.
Click
Apply
to have the configuration take effect.
You can see the link type, untagged VID, and tagged VID information of each port in
the table below on the screen.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
83
Page 92
Transition Networks SISPM1040-182D-LR
802.1Q VLAN interface
Group Configuration
Edit the existing VLAN Group.
Select the VLAN group in the table list.
Edit
Click
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
.
84
Page 93
Transition Networks SISPM1040-182D-LR
Group Configuration interface
You can modify the VLAN group name and VLAN ID.
Group Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
85
Page 94
Transition Networks SISPM1040-182D-LR
Click
Apply
.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
86
Page 95
Transition Networks SISPM1040-182D
6.19 Rapid Spanning Tree
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol
and provides for faster spanning tree convergence after a topology change. The system
also supports STP and the system will auto-detect the connected device that is running
STP or RSTP protocol.
6.19.1 RSTP System Configuration
The user can view spanning tree information of Root Bridge.
The user can modify RSTP state. After modification, click
Apply
.
¾ RSTP mode: The user must enable the RSTP function first before configuring
the related parameters.
¾ Priority (0-61440): The switch with the lowest value has the highest priority
and is selected as the root. If the value is changed, the user must reboot the
switch. The value must be a multiple of 4096 according to the protocol standard
rule.
¾ Max Age (6-40): The number of seconds a switch waits without receiving
Spanning-tree Protocol configuration messages before attempting a
reconfiguration. Enter a value between 6 through 40.
¾ Hello Time (1-10): The time that controls the switch to send out the BPDU
packet to check RSTP current status. Enter a value between 1 through 10.
¾ Forward Delay Time (4-30): The number of seconds a port waits before
changing from its Rapid Spanning-Tree Protocol learning and listening states to
the forwarding state. Enter a value between 4 through 30.
[NOTE]
Follow the rule as below to configure the MAX Age, Hello Time, and Forward
Delay Time.
2 x (Forward Delay Time value –1) > = Max Age value >= 2 x (Hello Time
value +1)
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 96
Transition Networks SISPM1040-182D-LR
RSTP System Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
88
Page 97
Transition Networks SISPM1040-182D
6.19.2 Port Configuration
This web page provides the port configuration interface for RSTP. You can assign higher
or lower priority to each port. Rapid spanning tree will have the port with the higher
priority in forwarding state and block other ports to make certain that there is no loop in
the LAN.
Select the port in the port column field.
Path Cost: The cost of the path to the other bridge from this transmitting bridge at
the specified port. Enter a number 1 through 200,000,000.
Priority: Decide which port should be blocked by setting its priority as the lowest.
Enter a number between 0 and 240. The value of priority must be the multiple of 16.
Admin P2P: The rapid state transitions possible within RSTP are dependent upon
whether the port concerned can only be connected to exactly another bridge (i.e. it
is served by a point-to-point LAN segment), or can be connected to two or more
bridges (i.e. it is served by a shared medium LAN segment). This function allows the
P2P status of the link to be manipulated administratively. True means the port is
regarded as a point-to-point link. False means the port is regarded as a shared link.
Auto means the link type is determined by the auto-negotiation between the two
peers.
Admin Edge: The port directly connected to end stations won’t create bridging loop
in the network. To configure the port as an edge port, set the port to “True” status.
Admin Non Stp: The port includes the STP mathematic calculation. True is not
including STP mathematic calculation. False is including the STP mathematic
calculation.
Click
Apply
.
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Page 98
Transition Networks SISPM1040-182D-LR
RSTP Port Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
90
Page 99
Transition Networks SISPM1040-182D
A
6.20 SNMP Configuration
Simple Network Management Protocol (SNMP) is the protocol developed to manage
nodes (servers, workstations, routers, switches and hubs etc.) on an IP network. SNMP
enables network administrators to manage network performance, find and solve network
problems, and plan for network growth. Network management systems learn of
problems by receiving traps or change notices from network devices implementing
SNMP.
6.20.1 System Configuration
Community Strings
Here you can define the new community string set and remove the unwanted community
string.
¾ String: Fill the name string.
¾ RO: Read only. Enables requests accompanied by this community string to
display MIB-object information.
¾ RW: Read/write. Enables requests accompanied by this community string to
display MIB-object information and to set MIB objects.
¾ Click
dd
.
¾ To remove the community string, select the community string that you defined
before and click
Remove
. The strings of Public_RO and Private_RW are default
strings. You can remove them but after resetting the switch to default, the two
strings show up again.
Agent Mode:
Select the SNMP version that you want to use it. And then click
Change
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
to switch to the selected SNMP version mode.
Page 100
Transition Networks SISPM1040-182D-LR
SNMP System Configuration interface
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
92