Thank you for your recent purchase of our humidifier. The addition of this product to your heating and cooling system will increase your level of comfort by adding just the right amount of moisture to your indoor environment. During the heating season, your humidifier will not only make you feel more comfortable, but it will help protect your home and your furnishings as well.
Your new humidifier is easy to use and easy to live with. Simple maintenance is required on a periodic basis to keep it in peak operating condition. This Use and Care manual will outline these steps for you, as well as other basic operating procedures so you can enjoy the full benefits of your new humidifier.
How Your Humidifier Operates:
During the winter, your comfort relies on two things: the perfect temperature and the perfect amount of moisture. Your new humidifier will provide your home with the recommended indoor relative humidity to ensure your comfort all winter long.
INTRODUCTIONTABLE OF CONTENTS
WARNING
ELECTRICAL SHOCK HAZARD.
Disconnect Electrical Power and Shut Off Water Supply Before Servicing. Failure to follow this warning may cause property damage, personal injury or death.
CAUTION
PERSONAL INJURY HAZARD.
Turn Humidifier Control to “OFF” or lowest setting before servicing. Sudden operation may cause personal injury or property damage.
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Operating Instructions
• Automatic Humidifier Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
• Manual Humidifier Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Effect of Water Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Annual Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Annual Summer Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Periodic Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
MAINTENANCE INSTRUCTIONS
Models *HUMD200ABM00B, *HUMD300ABA00B . . . . . . . . . . . . . . . .9
Model *HUMD500APA00B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Replacement Record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
© 2011 Trane. All rights reserved.
- 3 -- 2 -
TABLE 1 – Operation Guide
Models *HUMD300ABA00B and *HUMD500APA00B with Automatic Humidifier Control: (for Manual Humidifier Control – see page 5)
Your Automatic Humidifier Control is installed in the cold air return. During the first heating season, your Automatic Humidifier Control needs to be set initially to match your home’s condition. Please follow these steps when adjusting your Control (refer to Figure A).
1. Turn the dial setting knob to “5,” which is within the normal range. During the next 24-48 hours it may be necessary to adjust the dial for more or less humidity, depending on your personal comfort and home’s requirements. Refer to the “Operation Guide” (Table 1).
2. During the coldest portion of the first heating season, minor adjustments may be necessary. This is dependent upon your individual home construction, refer to the “Operation Guide” (Table 1).
Condition Solution
Condensation on windows Reduce the setting on the control dial
by 1 increment.
Lack of humidity Increase the setting on the control dial
by 1 increment.
Humidifier does not operate Turn dial to “Test.” Make certain furnace
and blower are operating. If humidifier still doesn’t operate, consult your air conditioning and heating dealer.
Humidifier won’t shut off Turn dial to “Off.” If humidifier continues
to operate, consult your air conditioning and heating dealer.
Test mode System operation is checked by setting the
knob to “Test.”Make certain furnaceand blower are operating. Humidifier will operate for one minute.
The relative humidity in your home will now be accurately controlled to meet your needs and should not need further adjustment during future heating seasons. Make note of the dial setting in the event you temporarily move the knob when performing annual maintenance of the Humidifier.
II. OPERATING INSTRUCTIONS
FIGURE A
Your new humidifier has been installed to operate in conjunction with your furnace. When the Humidifier Control calls for humidity and the furnace blower is operating, water flows to the distribution tray located at the top of the humidifier. The water is evenly distributed across the width of the tray and over the Humidifier Pad. Dry, hot air is moved through this moisture laden Humidifier Pad where it is evaporated into a vapor. This humidified air is circulated throughout your home. Humidified air helps to reduce static electricity, prevents wood furniture from drying out, helps prevent nasal passages from becoming too dry and makes your home more comfortable.
Important Notes About Your Humidifier:
When the humidifier is operating, there will be a small, steady stream of water to drain. Do not use the saddle valve to regulate the water flow. The saddle valve is designed to be either completely open or completely closed.
Although your humidifier incorporates a self-flushing action, the Humidifier Pad will develop mineral build-up over time. To assure high
capacity, trouble-free performance the Humidifier Pad should be replaced annually.
For water distribution trays with a synthetic fabric liner: The
synthetic fabric liner provides an even water flow over the Humidifier Pad. It is normal for some mineral deposits to form in the distribution tray as it dries out between humidification cycles. These deposits can actually help distribute water in the tray, but if they form enough to block the openings, they should be removed as described in the “Periodic Preventative Maintenance” section of this manual.
For water distribution trays with a granular coating: The coating on the bottom of the distribution tray provides an even flow of water over the Humidifier Pad. Do not clean the mineral scale off the bottom of the distribution tray at the end of the humidification season. The scale actually provides an excellent track for the water to follow.