Trane FURN-PRC001-EN User Manual

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace
XR 80
TUD040,060,080,100,120,140C
Single-Stage Fan Assisted Combustion System
PUB. NO. 22-1640-06-0702 (EN)

General Features

Natural Gas Models
Central Heating furnace designs are certified by the American and Canadian Gas Associations for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
Safe Operation
The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
Quick Heating
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm conditioned air to the structure.
Burners
Multi-port In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas.
Integrated System Control
Exclusively designed operational pro­gram provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connec­tion points for E.A.C./humidifier.
Air Delivery
The 4-speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
Styling Heavy gauge steel and “wrap-around” cabinet construction is used in the
cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass.
Features And General Operation
The XR 80 High Efficiency Gas Furnaces employ an adaptive Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a. Low energy power venter. b. Vent proving pressure switch.
© 2002 American Standard Inc. All Rights Reserved 2 22-1640-06-0702 (EN)
Contents
General Features 2 Features and Benefits 4
Standard Equipment 4 Optional Equipment 5
General Data 6
TUD040C924K 6 TUD040C930K 6 TUD060C924K 6 TUD060C936K 6 TUD080C924K 7 TUD080C936K 7 TUD080C948K 7 TUD080C960K 7 TUD100C936K 8 TUD100C945K 8 TUD100C948K 8 TUD100C960K 8 TUD100C972K 9 TUD120C954K 9 TUD120C960K 9 TUD140C960K 9
Performance Data 10 Field Wiring 12 Twinning Field Wiring 13 Dimensions 14 Electrical Data 15
22-1640-06-0702 (EN) 3

Features and Benefits

XR 80 Upflow/Horizontal Right Or Left

Standard Equipment

• Power supply 115/1/60
• Multi-port In-shot burners
• Integrated solid state control with self diagnostics
• Silicon Nitride hot surface igniter with adaptive heat up
• Complete front service access
• Heavy guage aluminized steel heat exchanger
• Slide out blower assembly
• Blower door safety switch
• Direct drive, 4-speed motor
• Cleanable high velocity filters
• Optional L.P. conversion kit
• Common vent
• Alternate bottom/left/right return air
• Hinged blower door
• Perfect Fit door latches
• Gasketed blower door
• Internal filter rack
• Cleanable high velocity filters
• Standard filter sizes
• Single wire twinning
• Selectable cooling fan off delay
• Left-right gas connection
• Optional L.P. conversion kit
• Common vent capability
• 24 volt fuse
• Manual reset flame roll out switches
• Insulated blower door
• Insulated blower compartment
• Accessory hook-up capability - Hum and EAC
• Blower door safety switch
• Left/right gas connection
• 24 volt fuse
• Manual reset burner box limit
Non-prorated 20-year heat ex-
changer limited warranty
5-year limited parts warranty
4 22-1640-06-0702 (EN)
Features and Benefits

Optional Equipment

Thermostat .............................................................................................................................................................. BAYSTAT388 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ................................................................................ AY28X092 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Vertically) ................................................................................ BAYSTAT305 [ ]
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .............................................................. TAYSTAT300C [ ]
Propane Conversion Kit ........................................................................................................................................ BAYLPKT210A [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFE145A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFE175A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ........................................................... TFE210A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFE245A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................................TFM145A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................TFM175A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ............................................................. TFM210A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................TFM245A9FR1 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) .............................................. TFP175A9FR01 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .................................................... TFP210A9FR01 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) .............................................. TFP245A9FR01 [ ]
Coil Enclosure (14-1/2" Wide Cabinets) ................................................................................................................ BAYCLE1400C [ ]
Coil Enclosure (17-1/2" Wide Cabinets) ................................................................................................................ BAYCLE1700C [ ]
Coil Enclosure (21" Wide Cabinets) ...................................................................................................................... BAYCLE2100C [ ]
Coil Enclosure (24-1/2" Wide Cabinets) ................................................................................................................ BAYCLE2400C [ ]
High Altitude Pressure Switch Kit .............................................................................................................................BAYHALT248 [ ]
Masonry Chimney Vent Kit ................................................................................................................................... BAYVENT800B [ ]
Filter Rack Kit ...................................................................................................................................................... BAYRACK960A [ ]
22-1640-06-0702 (EN) 5
Loading...
+ 11 hidden pages