Trane Comfort Control XB200 User Manual

Page 1
$
FAN MODEFILTER
XB200
Comfort
Control
Page 2
Table Of
Page - 2
Pub. No. 22-5204-01
Page
3 Introduction 4-10 Keypad functions 11-14 Features 15 Factory settings 16-17 Comfort Control Setup 18-19 Troubleshooting 20-21 Warranty
$
FAN MODEFILTER
Energy Savings Page 9.
Up Arrow - Increase temperature Page 5.
Down Arrow - Decrease temperature Page 5.
Filter Reminder Page 7.
Fan ON / OFF Page 6.
Mode: Heat, Cool Auto, Off Page 4.
Comfort Information Drawer Page 14.
Page 3
Introduction
Page - 3
Congratulations on the purchase of your new Trane XB200 Comfort Control! Your XB200 Comfort Control combines the latest digital control technology with intuitive functions that make this control simple to understand and easy to operate. You’ll enjoy lower utility bills at the touch of a button with the energy efficiency features built into your XB200 Comfort Control. Your comfort settings are automatically stored in the XB200 Comfort Control’s memory eliminating the need for battery backup in the event of power loss. Simply follow the steps in this instruction manual and begin enjoying the benefits of your new Trane XB200 Comfort Control.
Pub. No. 22-5204-01
Page 4
Page - 4
Pub. No. 22-5204-01
Keypad
Functions
Mode
Mode
MODE
- Pressing this key changes the system mode to Heat, Cool, Automatic or Off.
A border will appear around the mode on the display to show the system mode you’ve selected.
Page 5
Page - 5
Pub. No. 22-5204-01
UP / DOWN Arrow
- Use these keys to raise or lower the Heat or Cool Setting.
- The first key press turns on the back lighting and a border around the setting to be adjusted without changing the setting.
- Pressing the Up or Down arrow again will raise or lower the setting that has the border around it.
- If you press and hold the Up or Down arrow, the temperature setting will advance rapidly.
- When the control is set to Auto mode, pressing the Mode key once changes the position of the border to heat or cool.
Page 6
Page - 6
Pub. No. 22-5204-01
FAN
- Pressing this key selects whether the indoor fan motor runs in automatic or continuous mode.
The FAN ON indicates that you have selected to operate the fan in continuous mode.
Pressing the Fan keypad button again returns the indoor fan mode of operation to automatic and FAN ON goes away.
Fan
Fan
Keypad
Functions
(cont-)
Page 7
Page - 7
Pub. No. 22-5204-01
Filte r
Filte r
FILTER
- Press this key to display how many days remain before time to replace or clean the filter. The “FILTER” indicator will flash on the display when the filter timers days remaining reaches zero.
- Press the “FILTER” key after cleaning or replacing the filter to turn off the filter indicator and reset the timer.
- IF the filter is serviced before the timer expires, press the “FILTER” key to display the “days remaining for filter”. Press the Down arrow to change the remaining days to zero. Press the “FILTER” key twice to reset the timer.
Page 8
Page - 8
Pub. No. 22-5204-01
Filte r
Filte r
FILTER
- If you press and hold the filter keypad button for several seconds, the display changes to the Quick Setup option for the filter timer. Use the UP or DOWN arrow keypad buttons to change the timer setting if desired, 1 - 180 days.
NOTE: Setting to 0 will disable filter timer.
- Press the filter button again to return to normal display or just wait a few seconds and the display will return on its own.
Keypad
Functions
(cont-)
Page 9
Page - 9
$
Pub. No. 22-5204-01
$
Energy Savings
- Use this key to lower your systems energy consumption and save money at the same time! Pressing the Energy Savings keypad button changes the indoor tempera­ture setting to a warmer temperature when the system is operating in the cooling mode and to a cooler indoor temperature setting when operating in the heating mode. Energy Savings will appear on the display.
$
Example: Heating offset of 8 degrees.
Page 10
Page - 10
Pub. No. 22-5204-01
- Press and hold the Energy Savings keypad button to gain Quick Access to the Energy Savings setup screen.
- Use the UP or DOWN arrow keys to change the offset degrees setting.
NOTE: Energy Savings offset degrees are selected separately for heating and cooling.
Press the Mode keypad button while viewing this screen to access the Cooling or Heat­ing offset degrees setting, then use the UP or DOWN arrow key to select the desired number of offset degrees.
- Press the Energy Savings keypad button again to return to normal display or just wait a few seconds and the display will return on its own.
$
Keypad
Functions
(cont-)
Page 11
Page - 11
Pub. No. 22-5204-01
Features
Adjusting to new setting
Auto Changeover
When the system mode is set to Auto, the control automatically switches between heating and
cooling modes to maintain the desired comfort level.
Appears when equipment is energized.
Setpoint Deadband
The number of degrees separating Heating and Cooling setpoints. The amount of separation
between mode setpoints is user defined between 2 and 10 degrees. When the control is set to Auto, and the cooling setpoint is changed to a cooler setting, the heating setpoint also changes to maintain the selected degrees separation.The same action occurs when the heat­ing setpoint is changed to a warmer temperature.
Page 12
Page - 12
Pub. No. 22-5204-01
Backlit Display & Keys
The liquid crystal display and keypad will illuminate whenever a keypad button is pressed to improve thermostat visibility. The back light stays on for 10 seconds after the last key press. The Up and Down arrows are continuously lit.
Cooling Droop
Cooling Droop is an automatic function that cycles the compressor on to improve indoor comfort by removing moisture from the air. The Droop cycle is activated when space tem­perature is at or below the cooling sensible temperature setpoint. When this function is active, the control will control indoor temperature at 1 or 2 degrees below cooling setpoint. The Droop cycle is deactivated when the indoor temperature rises above the cooling setpoint.
Keypad Lock
Locking the control keypad can help prevent unwanted tampering or changing the control settings by pressing the controls UP and DOWN arrow keypad buttons at the same time and holding for 2 seconds. The “KEYPAD LOCKED” icon will appear on the control’s display. Repeating this combination unlocks the keypad.
Features
(cont-)
Page 13
Page - 13
Pub. No. 22-5204-01
Filter Reminder
FILTER” will automatically flash to remind the homeowner that its time to change the filter once the preset time has expired. Pressing the FILTER” keypad button automatically resets the internal clock timer. Once the timer has been reset, the number of days remaining till the next filter change can easily be determined by simply pressing the FILTER” keypad button. Pressing and holding the FILTER” keypad button provides quick access to the filter timer setup.
Energy Savings
The Energy Savings mode provides instant energy savings by offsetting the indoor setpoint to a cooler temperature setting for heating and a warmer temperature setting for cooling. The Energy Savings mode is activated by pressing the Energy Savings key “$” on the control keypad. Pressing the Energy Savings key “$” again deactivates the Energy Savings mode. Pressing and holding the Energy Savings key “$” provides quick access to the offset degree setup for the current operating mode.
Default Factory Settings
The control is shipped with a set of factory default settings. The factory default settings can be restored at any time using the control configuration menu. Please see Page 15 for a com­plete listing of factory shipped default settings.
Page 14
Page - 14
Pub. No. 22-5204-01
Features
(cont-)
Service Indicator
“SERVICE” automatically flashes when an internal fault or error has been detected by the
control. See Table 2 on pages 18.
Wait Indicator
“WAITING” will illuminate when the indoor setpoint is moved in the direction of calling
for additional system capacity. “WAITING” idicates that the control is adjusting to the new settings.
Calibrate Indoor Temperature
This option allows calibration (or deliberate miscalibration) of the room temperature sensor. The selection is the number of degrees added to actual temperature. The number can range between + 5 and - 5. Factory default is 0. This adjusted value will be used as actual tempera­ture for both display and control action. For example, if 2 is selected, 72 degrees actual will read 74 degrees.
Comfort Information Drawer
The drawer attached to the mounting base of the control is designed to provide a convenient location for the home owner to locate their local servicer. A standard business card can be folded and inserted into the slot on the drawer to remind the User whom to call when service is required.
Page 15
Page - 15
Pub. No. 22-5204-01
Factory
Default
Settings
User Defined Options and Factory Default Settings: (See Table 1, page 17)
Temperature Display - Fahrenheit or Celsius (Default is Fahrenheit) Auto or Manual Changeover - (Default is Auto) Setpoint Deadband - 2 - 10 degrees (Default is 3 degrees) Waiting Indicator - Enable or Disable (Default is Enable) Cooling Droop - Off, 1, or 2 degrees (Default is 1 degree) Energy Saving Cooling Setpoint Offset - 0 - 25 degrees (Default is 5 degrees) Energy Saving Heating Setpoint Offset - 0 - 45 degrees (Default is 5 degrees) Indoor Filter Timer Method - Calendar Days or Fan Run Time Days - (Default is Calendar Days) Indoor Filter Timer Days - 1 - 180 days (Default is 30 days) Calibrate Indoor Temperature - + / - 5 Degrees (Default is 0 degrees)
Page 16
Page - 16
Pub. No. 22-5204-01
Entering User Setup: Press and hold the MODE and FAN keypad buttons at the same time.
Keypad Navigation:
- Use the MODE or FAN buttons to navigate forward and backward through the Setup steps.
- Press MODE to advance forward to the next step.
- Press FAN to return to the previous step.
- Use the UP and DOWN arrow keypad buttons to select or change Setup options.
User
Setup
Options
Page 17
Page - 17
Pub. No. 22-5204-01
Table 1
Comfort Control Setup
Menu Item
Factory Setting
Setting (Choices)
(Press UP or DOWN arrow)
Step
(Press
Mode or
Fan)
Menu Item
Factory Setting
Setting (Choices)
(Press UP or DOWN
arrow)
Step
(Press Mode or Fan)
Temperature
Display
0
0 = Fahrenheit 1 = Celcius
40
Energy Savings ­Heating Setpoint Offset
5
1 - 45 Degrees Fahrenheit 1 - 25 Degrees Celcius
46
Auto or Manual
Changeover
1
0 = Manual 1 = Auto
41
Indoor Filter Timer Method
0
0 = Calendar Days 1 = Fan Run Time Days
47
Setpoint Deadband 3 2 - 10 Degrees 42
Indoor Filter Reminder - Days
30
1 - 180 Days 0 = Disable
48
Waiting Icon 1
0 = Disable 1 = Enable
43
Calibrate Indoor Temperature
0
Calibrated Room Temperature + / - 5 Degrees (1/2 degree increments)
49
Cooling Droop 1
0 = Off 1 = 1 Degree 2 = 2 Degrees
44
Exit Setup (Press Mode)
SA
SA = Save US = Default User Settings CA = Cancel
99
(Exit)
Energy Savings ­Cooling Setpoint Offset
5
1 - 25 Degrees Fahrenheit 1 - 15 Degrees Celcius
45
Note: Pressing the Energy Savings Key ($) anytime during setup will advance to step 99. Step 99 - Make setting selection and then press MODE to exit. SA
ve = Save selections
US
er = Default user settings
CA
ncel = Cancel Selections for current session and return to previous session selections.
Lock - Unlock Keypad:
Press and hold Up Arrow and Down Arrow at the same time.
(“Keypad Locked” icon will display on LCD screen)
User
Setup
Options
(cont-)
Page 18
Trouble
-shooting
Page - 18
Pub. No. 22-5204-01
Table 2
Troubleshooting
Symptom Possible Cause Action
Display will not come on.
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch OFF.
3. Furnace blower compartment door or panel loose or not properly installed.
1. Replace fuse or reset breaker.
2. Turn switch to ON.
3. Replace door panel in proper position to engage safety interlock or door switch.
Temperature display is incorrect. Temperature display needs calibration. Calibrate Sensor - User Setup Step 49.
Cannot set Heating setpoint above 80 degrees
Deadband between Heating and Cooling set to high Decrease Deadband setting - User Setup Step 42.
"Service" Flashing on and off. Control EEPROM write error. Press any key and Check / Re-enter Setup Choices.
"Service" solid on and "--" in temperature display.
Indoor temperature sensor open or shorted Replace Control
Temperature setting will not change. (Example: Cannot set heating higher or cooling lower).
1. Upper and/or lower temperature limits were reached.
2. "Keypad locked" is displayed on LCD.
1. Check the temperature setpoints: Heating limits are 40 - 85F. Cooling limits are 65 - 90F.
2. Unlock keypad - press Up+Down arrow together until icon disappears.
Page 19
Page - 19
Pub. No. 22-5204-01
Table 2 Troubleshooting
(Continued)
Symptom Possible Cause Action
Heating will not come on.
1. System Mode not set to Heat.
2. Minimum off time delay being enforced. "waiting displayed".
3. Loose connection to control or system.
4. Heating system requires service or control requires replacement.
1. Set Mode to heat and raise the setpoint above room temperature.
2. If heating does not come on within 5 minutes, Check Heating.
3. Check - Repair connections.
4. Repair system / Replace control.
Cooling will not come on.
1. System Mode not set to Cool.
2. Minimum off time delay being enforced "waiting displayed".
3. Loose connection to control or system.
4. Cooling system requires service or control requires replacement.
1. Set Mode to cool and lower the setpoint below room temperature.
2. If cooling does not come on within 15 minutes, contact servicer.
3. Repair connections.
4. Repair system / Replace control.
Cool ON or Heat ON is displayed, but no warm or cool air is coming from the registers.
1. The heating equipment turns on the fan when the furnace has warmed up to a setpoint.
2. Heating or cooling equipment is not operating.
1. Wait one minute after seeing the ON icon and then check the registers.
2. Check Heating and Cooling system.
Control does not respond to keypad presses.
1. "Keypad locked" icon is displayed on LCD.
2. Keypad failure.
1. Unlock keypad - press Up+Down arrow together until "Keypad Locked" disappears.
2. Replace Control.
Fan does not operate properly in heat or cool mode.
1. Incorrect wiring.
2. Heating or cooling equipment inoperative.
1. Correct wiring.
2. Repair system.
Fan runs all the time.
1. Fan mode set to ON.
2. Shorted control wiring.
1. Set fan mode to AUTO.
2. Check / Repair wiring.
Page 20
Warranty
Limited Warranty Low Voltage Comfort Control
This warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the
Comfort Control is originally
affixed, and applies to products purchased and retained for use within the U.S.A. and Canada.
If any part of your
Comfort Control fails because of a manufacturing defect within 5
years from the date of the original purchase, Warrantor will furnish, without charge, a new Comfort Control. Any local transportation, related service labor and diagnosis
calls are not included.
This Warranty does not cover failure of your
Comfort Control if it is damaged while in
your possession or if the failure is caused by unreasonable use. In no event shall Warran­tor be liable for incedental or consequential damages. In no event shall any implied
warranty of merchandise or fitness for use exceed the terms of the limited warranty stated above.
Page - 20
Pub. No. 22-5204-01
Page 21
Page - 21
Some states do not allow limitations on how long an implied warranty last or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Parts will be provided by our factory organization or an authorized service organization in your area. All you need to do is look us up in the Yellow Pages or write to the address given below. If you wish further help or information concerning this warranty, contact:
American Standard Inc. Troup Highway Tyler, Texas 75711-9010 Attention: Manager, After Sale Support
Pub. No. 22-5204-01
Page 22
Page - 22
Pub. No. 22-5204-01
Page 23
Pub. No. 22-5204-01
Page - 23
Page 24
American Standard Inc.
6200 Troup Highway
Tyler, Texas 75711
For more information contact your local dealer (distributor)
Pub. No. 22-5204-01
Loading...