TRACO TML30252, TML30215, TML30212, TML30205, TML30124 Datasheet

...
0 (0)
TRACO TML30252, TML30215, TML30212, TML30205, TML30124 Datasheet

Encapsulated Power Supply

 

 

 

 

 

 

 

 

TML Series

5 – 30 Watt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Features

Switching Power Modules for PCB Mounting

Fully encapsulated Plastic Case

Single, Dual and Triple Output Models

Universal Input 85-264 VAC, 47 - 440 Hz

High Efficiency

EMI meets EN 55022, Class B and

FCC, Level B

Low Ripple and Noise

Short Circuit and Overload Protection

Safety Class II Product (30 Watt Models)

2 Year Product Warranty

The TML Series switching power supplies, offer high power density in a fully encapsulated module. This feature makes these modules an ideal solution for all space critical applications in commercial and industrial electronic equipment. Full compliance to European low voltage and EMC directive, UL and cUL safety approval qualifies this product for worldwide markets. SMD-technology and a high efficiency guarantees a high reliability of these Power Supplies.

Models

 

OrderCode

Output Power

Output 1

Output 2

Output 3

 

 

max.

Inom

 

Inom

 

Inom

 

TML 05105

 

5 VDC / 1000 mA

 

 

 

 

TML 05112

 

12 VDC /

416 mA

 

 

 

 

TML 05115

 

15 VDC /

333 mA

 

 

 

 

TML 05124

5 Watt

24 VDC /

200 mA

 

 

 

 

TML 05205

 

5 VDC /

500 mA

–5 VDC /

500 mA

 

 

TML 05212

 

12 VDC /

200 mA

–12 VDC /

200 mA

 

 

TML 05215

 

15 VDC /

160 mA

–15 VDC /

160 mA

 

 

TML 10105

 

5 VDC / 2000 mA

 

 

 

 

TML 10112

 

12 VDC /

833 mA

 

 

 

 

TML 10115

 

15 VDC /

666 mA

 

 

 

 

TML 10124

10 Watt

24 VDC /

416 mA

 

 

 

 

TML 10205

 

5 VDC /

800 mA

–5 VDC /

800 mA

 

 

TML 10212

 

12 VDC /

380 mA

–12 VDC /

380 mA

 

 

TML 10215

 

15 VDC /

300 mA

–15 VDC /

300 mA

 

 

 

 

 

 

 

 

 

http://www.tracopower.com

Page 1

Encapsulated Power Supply

 

 

 

 

 

TML Series

5 – 30 Watt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

 

OrderCode

Output Power

Output 1

Output 2

Output 3

 

 

max.

Inom

 

Inom

 

Inom

 

 

TML 15105

 

5 VDC / 3000 mA

 

 

 

 

 

TML 15112

 

12 VDC / 1250 mA

 

 

 

 

 

TML 15115

 

15 VDC / 1000 mA

 

 

 

 

 

TML 15124

 

24 VDC /

625 mA

 

 

 

 

 

TML 15205

15 Watt

5 VDC / 1500 mA

–5 VDC / 1500 mA

 

 

 

TML 15212

 

12 VDC /

650 mA

–12 VDC /

650 mA

 

 

 

TML 15215

 

15 VDC /

500 mA

–15 VDC /

500 mA

 

 

 

TML 15512

 

5 VDC / 2000 mA

12 VDC /

200 mA

–12 VDC /

200 mA

 

TML 15515

 

5 VDC / 2000 mA

15 VDC /

150 mA

–15 VDC /

150 mA

 

TML 30103

 

3.3 VDC / 6000 mA

 

 

 

 

 

TML 30105

 

5 VDC / 6000 mA

 

 

 

 

 

TML 30112

 

12 VDC / 2500 mA

 

 

 

 

 

TML 30115

 

15 VDC / 2000 mA

 

 

 

 

 

TML 30124

 

24 VDC / 1250 mA

 

 

 

 

 

TML 30205

30 Watt

5 VDC / 3000 mA

–5 VDC / 3000 mA

 

 

 

TML 30212

 

12 VDC / 1300 mA

–12 VDC / 1300 mA

 

 

 

TML 30215

 

15 VDC / 1000 mA

–15 VDC / 1000 mA

 

 

 

TML 30252

 

* 5 VDC / 3000 mA

* 12 VDC / 1250 mA

 

 

 

TML 30512

 

* 5 VDC / 3000 mA

12 VDC /

630 mA

–12 VDC /

630 mA

 

TML 30515

 

* 5 VDC / 3000 mA

15 VDC /

500 mA

–15 VDC /

500 mA

 

 

 

 

* Output floating

 

 

 

Input Specifications

Input voltage range

85 – 264 VAC

Input frequency

47 – 440 Hz

Input current no load

115 VAC/230 VAC

– TML 5 models

10 mA / 15 mA typ.

– TML 10 models

15 mA / 20 mA typ

– TML 15 models

18 mA / 25 mA typ.

– TML 30 models

30 mA / 55 mA typ.

Input current full load

115 VAC/230 VAC

– TML 5 models

160 mA / 80 mA typ.

– TML 10 models

200 mA / 120 mA typ

– TML 15 models

280 mA / 165 mA typ.

– TML 30 models

550 mA / 320 mA typ.

Inrush current (< 2 ms)

115 VAC / 230 VAC

 

10 A max / 20 A max

External fuse (recommended)

1.5 A slow blow type

All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.

http://www.tracopower.com

Page 2

Encapsulated Power Supply

TML Series 5 – 30 Watt

Output Specifications

Voltage set accuracy

 

± 2 %

 

 

 

 

 

Regulation

– Input variation

± 0.3 % max.

 

 

– Load variation (10 – 100%)

 

 

 

– Single output models

± 1.0 % max.

 

 

– Dual/ triple output models

± 5 % max.

 

 

 

 

Minimum load (only triple output models)

10 % (main output)

 

 

 

 

Ripple and noise (20 MHz Bandwidth) – 3.3 & 5 VDC output models:

< 1.5 % of Vout

 

 

– other models:

< 1.0 % of Vout

 

 

 

 

 

Current limitation

 

120 – 180 % fold back

 

 

 

Short circuit protection

hiccup mode, indefinite (automatic recovery)

 

 

Maximum capacitive load

470 – 50’000 µF depending on model

 

 

 

General Specifications

 

 

Temperature ranges

– Operating

– 25 °C…+71 °C ambient temp. max.

 

– Power derating above 50°C

3.75 %/°C

 

 

– Storage (non operating)

– 40 °C…+85 °C

 

 

 

 

Temperature coefficient

0.02 % / °C

 

 

 

 

Efficiency

 

72 – 80 % (depending on model)

 

 

 

Humidity (non condensing)

95 % rel max.

 

 

 

 

Switching frequency

 

100 kHz typ. (Puls width modulation PWM)

 

 

 

Hold-up time

 

40 ms min. ( Vin 115...230 VAC)

 

 

 

 

Isolation voltage

– Input/ Output

3‘000 VAC

 

 

 

 

Reliability /calculated MTBF (MIL-HDBK-217E)

> 660’000 h @ 25°C

 

 

 

 

EMI / RFI conducted

 

EN 55022, class B, FCC part 15, level B

 

 

 

 

EMC compliance

– Electrostatic discharge ESD

IEC / EN 61000-4-2 level 2

4 kV / 8 kV

 

– RF field susceptibility

IEC / EN 61000-4-3 level 4

3 V/m

 

– Electrical fast transients/bursts on mainsline

IEC / EN 61000-4-4 level 4

1 kV

 

 

 

Safety Class II (only 30 watt models)

to IEC / EN 60536

 

 

 

 

Safety standards

 

UL 1950, IEC 60950, EN 60950

 

 

 

 

Safety approval

 

cUL /UL File E188913

 

 

 

 

 

Case material

 

Plastic resin + Fiberglass

 

 

 

(flammability to UL 94-V0)

 

 

 

 

 

All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.

http://www.tracopower.com

Page 3

Loading...
+ 4 hidden pages