Switching Power Supplies
|
|
|
|
|
SXI Series |
15 - 150 Watt |
|
|
|
|
|
||
|
|
|
|
|||
|
|
|
|
|
||
|
|
|
|
|
|
|
Features
Boxed Power Supplies with Screw
Terminal Block
Singleand Triple Output Models
EMI Compliance with EN 55022 and
FCC Part 15, Level B
Short Cirquit Protection
Overvoltage Protection
High Efficiency
Industrial Grade Components
2 Year Product Warranty
The SXI-series are very compact switching power supplies for cost critical applications. They deliver 15 to 150 W of continuous power. Use of high quality components and good thermal dissipation make them a very reliable product with a calculated MTBF up to 200’000 h.
Models with Single Output
Ordercode |
Output Power, max |
Output Voltage |
Output Current max. |
||
SXI 15-03S |
|
3.3 |
VDC |
3.0 A |
|
SXI 15-05S |
15 Watt |
5 |
VDC |
3.0 A |
|
SXI 15-12S |
12 |
VDC |
1.3 A |
||
|
|||||
SXI 15-24S |
|
24 |
VDC |
0.7 A |
|
SXI 30-03S |
|
3.3 |
VDC |
6.0 A |
|
SXI 30-05S |
30 Watt |
5 |
VDC |
6.0 A |
|
SXI 30-12S |
12 |
VDC |
2.6 A |
||
|
|||||
SXI 30-24S |
|
24 |
VDC |
1.4 A |
|
SXI 50-03S |
|
3.3 |
VDC |
10.0 A |
|
SXI 50-05S |
50 Watt |
5 |
VDC |
9.5 A |
|
SXI 50-12S |
12 |
VDC |
4.2 A |
||
|
|||||
SXI 50-24S |
|
24 |
VDC |
2.2 A |
|
SXI 100-05S |
|
5 |
VDC |
20.0 A |
|
SXI 100-12S |
100 Watt |
12 VDC |
8.4 A |
||
SXI 100-24S |
|
24 |
VDC |
4.4 A |
|
SXI 150-05S |
|
5 |
VDC |
30.0 A |
|
SXI 150-12S |
150 Watt |
12 VDC |
12.5 A |
||
SXI 150-24S |
|
24 |
VDC |
6.5 A |
|
|
|
|
|
|
http://www.tracopower.com |
Page 1 |
Switching Power Supplies
|
|
|
|
|
|
|
|
|
SXI Series |
15 - 150 Watt |
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|||||
Models with Multioutput |
|
|
|
|
|
||||||
Ordercode |
|
Output Power |
Output1 |
|
Output 2 |
Output 3 |
|||||
|
|
|
|
|
|
|
|
(floating) |
|
|
|
SXI 15-0522T |
|
15 Watt |
5 VDC/ 1.5 A |
|
+12 VDC/ 0.6 A |
–12 VDC /0.4 A |
|||||
SXI 15-0533T |
|
5 VDC/ 1.5 A |
|
+15 VDC/ 0.5 A |
–15 VDC /0.3 A |
||||||
|
|
|
|||||||||
SXI 30-0522T |
|
30 Watt |
5 VDC/ 4.0 A |
|
+12 VDC/ 1.2 A |
–12 VDC /0.6 A |
|||||
SXI 30-0533T |
|
5 VDC/ 4.0 A |
|
+15 VDC/ 1.0 A |
–15 VDC /0.5 A |
||||||
|
|
|
|||||||||
SXI 50-0522T |
|
50 Watt |
5 VDC/ 6.0 A |
|
+12 VDC/ 1.5 A |
–12 VDC /0.8 A |
|||||
SXI 50-0522T |
|
5 VDC/ 6.0 A |
|
+15 VDC/ 1.2 A |
–15 VDC /0.7 A |
||||||
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
Input Specifications
Input voltage range |
|
170 – 264 VAC |
|
|
|
Input frequency |
|
47 – 63 Hz |
|
|
|
Input current (at full load) |
SXI 15 |
0.24 A typ. |
|
SXI 30 |
0.46 A typ. |
|
SXI 50 |
0.75 A typ. |
|
SXI 100 |
0.65 A typ. |
|
SXI 150 |
1.00 A typ. |
|
|
|
Inrush current at 25°C (< 2ms) |
SXI 15/30 |
20 A typ. |
|
SXI 50 |
28 A typ. |
|
SXI 100/150 |
15 A typ. |
|
|
|
Start-up time |
|
100 ms max. |
|
|
|
Output Specifications |
|
|
Output voltage adjustment range |
– Single output models |
± 10 % |
|
– Mulioutput models (Output 1) |
± 5 % |
|
(Output 2 & 3) |
± 5 % (Factory set/ fixed) |
|
|
|
Regulation |
– Input variation |
± 0.2 % max. |
|
– Load variation (10 – 90%) |
± 0.5 % max. |
|
|
|
Ripple and noise (20Mhz Bandwidth) |
|
80 mV pk-pk max. |
|
|
|
Output current limitation |
|
120 – 140 % Inom. |
|
|
|
Overload protection mode |
|
constant current |
Over voltage protection (only ooutput 1) |
110 – 130 % Vout nom. |
|
Capacitive load |
|
10’000 µF |
|
|
|
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com |