This Installation Guide describes the hardware characteristics, installation methods and the
points that should be attended to during the installation. This Installation Guide is structured as
follows:
Chapter 1 Introduction
This chapter describes the external components of the switch.
Chapter 2 Installation
This chapter illustrates how to install the switch.
Chapter 3 Connection
This chapter illustrates how to do the physical connection of the switch.
Appendix A Troubleshooting
Appendix B Hardware Specifications
Audience
This Installation Guide is for:
Network Engineer Network Administrator
Conventions
• Some models featured in this guide may be unavailable in your country or region. For local sales
information, visit http://www.tp-link.com.
• The figures in Chapter 2 to Chapter 3 are for demonstration purposes only. Your switch may differ
in appearance from that depicted.
• This Guide uses the specific formats to highlight special messages. The following table lists the
notice icons that are used throughout this guide.
Remind to be careful. A caution indicates a potential which may result in device damage.
Remind to take notice. The note contains the helpful information for a better use of the
product.
Related Document
The User Guide and CLI Reference Guide of the product are provided on the resource CD. To
obtain the latest product information, please visit the official website:
3.6 Accessing the Switch ....................................................13
Appendix A Troubleshooting ———————— 14
Appendix B Specications ————————— 15
JetStream Smart Switch
RJ45 Port
Port and PoE Port
Switch Button
Chapter 1 Introduction
1.1 Product Overview
Designed for workgroups and departments, TP-Link JetStream Smart Switch provides wire-speed
performance and abundant L2 management features. It provides a variety of service features and
multiple powerful functions with high security.
The EIA-standardized framework and smart configuration capacity can provide flexible solutions for
a variable scale of networks. QoS and IGMP snooping/filtering optimize voice and video application.
Link aggregation increases aggregated bandwidth, optimizing the transport of business critical
data. SNMP, RMON, WEB and CLI Login bring abundant management policies. TP-LINK Gigabit Smart
Switch integrates multiple functions with excellent performance, and is friendly to manage, which
can fully meet the need of the users demanding higher net working performance.
T1500-28PCT/T1500G-10PS/T1500G-10MPS/T1600G-28PS (TL-SG2424P)/T1600G-52PS (TLSG2452P) is also a Power Sourcing Equipment (PSE*). Some of the RJ45 ports on the switch support
Power over Ethernet (PoE*) function, which can automatically detect and supply power with those
powered devices (PDs*) complying with IEEE 802.3af and IEEE 802.3at.
*PSE: a device (switch or hub for instance) that provides power through an Ethernet cable.
*PoE: a technology describes a system to transmit electrical power, along with data, to remote
devices over standard twisted-pair cable in an Ethernet.
*PD: a device powered by a PSE and thus consumes energy. Examples include powering network
cameras, wireless LAN access points, IP telephones, network hubs, embedded computers etc.
1.2 Appearance
■
Front Panel
The front panel of T1500-28TC (TL-SL2428) is shown as the following figure.
Figu re 1-1 Front Panel of T1500-28TC (TL-SL2428)
LEDsResetSFP Port10/100Mbps RJ45
Port
The front panel of T1500-28PCT (TL-SL2428P) is shown as the following figure.
Figu re 1-2 Front Panel of T1500-28PCT (TL-SL2428P)
LEDsResetSFP Port10/100/1000Mbps
LED Mode
10/100Mbps RJ45
10/100/1000Mbps
RJ45 Port
01Introduction
JetStream Smart Switch
The front panel of T1500G-10MPS is shown as the following figure.
Figu re 1-3 Front Panel of T1500G-10MPS
LEDsLED Mode
Switch Button
Reset10/100/1000Mbps
RJ45 Port and PoE Port
SFP Port
The front panel of T1600G-18TS (TL-SG2216) is shown as the following figure.
Figu re 1-4 Front Panel of T160 0G-18TS (TL-SG2216)
LEDsReset10/100/1000Mbps RJ45 Port SFP Port
The front panel of T1600G-28TS is shown as the following figure.
Figu re 1-5 Front Panel of T160 0G-28TS
10/100/1000Mbps RJ45 PortLEDsResetSFP Port
The front panel of T1600G-28PS is shown as the following figure.
Figu re 1-6 Front Panel of T160 0G-28PS
LEDsReset10/100/1000Mbps
Switch Button
RJ45 Port
SFP PortLED Mode
The front panel of The T1600G-52TS (TL-SG2452) is shown as the following figure.
Figu re 1-7 Front Panel of T160 0G-52TS (TL-SG2452)
ResetLEDs10/100/1000Mbps RJ45 PortSFP Port
02Introduction
JetStream Smart Switch
The front panel of The T1600G-52PS (TL-SG2452P) is shown as the following figure.
Figu re 1-8 Front Panel of T160 0G-52PS (TL-SG2452P)
Reset LED Mode Switch
Button
LEDs
10/100/1000Mbps RJ45 PortSFP Port
The front panel of The T1700G-28TQ is shown as the following figure.
Figu re 1-9 Front Panel of T1700G-28TQ
LEDsUnit ID LED Reset10/100/1000Mbps RJ45 PortSFP+ Port
The front panel of The T1700X-16TS is shown as the following figure.
Off: The switch is powered off or power supply is abnormal.
Flashing: Power supply is abnormal.
Flashing: The switch works properly.
On or Off: The switch works improperly.
On: A device is connected to the corresponding port but no activity.
Flashing: Data is being transmitted or received.
Off: No device is connected to the corresponding por t.
Note: 10/100M for T1500-28TC. Link /Act for T1600G-18TS (TL-SG2216), T1600G28TS, T1700G-28TQ.
1000Mbps
On: Running at 1000Mbps.
Off: Running at 10/100Mbps or no device is linked to the corresponding por t.
Note: For T1600G-18TS (TL-SG2216), T1600G-28TS, T1700G-28TQ.
03Introduction
JetStream Smart Switch
LEDIndication
Green On: Running at 1000Mbps, but no activity.
Green Flashing: Running at 1000Mbps and is transmitting or receiving data.
1000M
10/10 0/100 0Mbps
Link/Act
25-28
Lick /Act
Link/Act
Master
Fan
Yel low On : Running at 10/100Mbps, but no activity.
Yellow Flashing: Running at 10/100Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: 1000M for T1500 -28TC. 10/100/1000Mbps for 1-48 ports of T1600G-52TS
( TL-SG2 452 ).
On: A 1000Mbps device is connected to the corresponding SFP port but no activity.
Flashing: Data is being transmitted or received.
Off: A 10/100Mbps device or no device is connected to the corresponding SFP
port.
Note: Only for 49-52 ports of T1600G-52TS (TL-SG2452).
Green On: Running at 10Gbps, but no activity.
Green Flashing: Running at 10Gbps and is transmitting or receiving data.
Yel low On : Running at 1000Mbps, but no activit y.
Yellow Flashing: Running at 1000Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: 25-28 for T1700G-28TQ. Link/Act for 13-16 ports of T1700X-16TS.
Green On: Running at 10Gbps, but no activity.
Green Flashing: Running at 10Gbps and is transmitting or receiving data.
Yel low On : Running at 100/1000Mbps, but no activity.
Yellow Flashing: Running at 100/1000Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: Only for 1-12 ports of T1700X-16TS.
On: The switch works as master in the stack system, or does not join any stack
system.
Off: The switch works as stack member in the stack system.
Note: Only for T1700G-28TQ.
Green: All the fans work properly.
Yel low : Not all the fans work properly.
Off: The switch is working abnormally.
Note: Only for T1700X-16TS.
T1500-28PCT (TL-SL2428P) / T1500G-10MPS / T1600G-28PS / T1600G-52PS (TL-SG2452P) has an
LED mode switch button which is used to switch the LED status indication. When the Speed LED is
on, the port LED is indicating the data transmission rate. When the PoE LED is on, the port LED is
indicating the power supply status. By default the Speed LED is on. Pressing the mode switch button,
the Speed LED will turn off and the PoE LED will light up. Then the PoE LED will turn off after being on
for 60 seconds and the Speed LED will light up again.
04Introduction
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.