This Installation Guide describes the hardware characteristics, installation methods and the
points that should be attended to during the installation. This Installation Guide is structured as
follows:
Chapter 1 Introduction
This chapter describes the external components of the switch.
Chapter 2 Installation
This chapter illustrates how to install the switch.
Chapter 3 Connection
This chapter illustrates how to do the physical connection of the switch.
Appendix A Troubleshooting
Appendix B Hardware Specifications
Audience
This Installation Guide is for:
Network Engineer Network Administrator
Conventions
• Some models featured in this guide may be unavailable in your country or region. For local sales
information, visit http://www.tp-link.com.
• The figures in Chapter 2 to Chapter 3 are for demonstration purposes only. Your switch may differ
in appearance from that depicted.
• This Guide uses the specific formats to highlight special messages. The following table lists the
notice icons that are used throughout this guide.
Remind to be careful. A caution indicates a potential which may result in device damage.
Remind to take notice. The note contains the helpful information for a better use of the
product.
Related Document
The User Guide and CLI Reference Guide of the product are provided on the resource CD. To
obtain the latest product information, please visit the official website:
3.6 Accessing the Switch ....................................................13
Appendix A Troubleshooting ———————— 14
Appendix B Specications ————————— 15
Page 5
JetStream Smart Switch
RJ45 Port
Port and PoE Port
Switch Button
Chapter 1 Introduction
1.1 Product Overview
Designed for workgroups and departments, TP-Link JetStream Smart Switch provides wire-speed
performance and abundant L2 management features. It provides a variety of service features and
multiple powerful functions with high security.
The EIA-standardized framework and smart configuration capacity can provide flexible solutions for
a variable scale of networks. QoS and IGMP snooping/filtering optimize voice and video application.
Link aggregation increases aggregated bandwidth, optimizing the transport of business critical
data. SNMP, RMON, WEB and CLI Login bring abundant management policies. TP-LINK Gigabit Smart
Switch integrates multiple functions with excellent performance, and is friendly to manage, which
can fully meet the need of the users demanding higher net working performance.
T1500-28PCT/T1500G-10PS/T1500G-10MPS/T1600G-28PS (TL-SG2424P)/T1600G-52PS (TLSG2452P) is also a Power Sourcing Equipment (PSE*). Some of the RJ45 ports on the switch support
Power over Ethernet (PoE*) function, which can automatically detect and supply power with those
powered devices (PDs*) complying with IEEE 802.3af and IEEE 802.3at.
*PSE: a device (switch or hub for instance) that provides power through an Ethernet cable.
*PoE: a technology describes a system to transmit electrical power, along with data, to remote
devices over standard twisted-pair cable in an Ethernet.
*PD: a device powered by a PSE and thus consumes energy. Examples include powering network
cameras, wireless LAN access points, IP telephones, network hubs, embedded computers etc.
1.2 Appearance
■
Front Panel
The front panel of T1500-28TC (TL-SL2428) is shown as the following figure.
Figu re 1-1 Front Panel of T1500-28TC (TL-SL2428)
LEDsResetSFP Port10/100Mbps RJ45
Port
The front panel of T1500-28PCT (TL-SL2428P) is shown as the following figure.
Figu re 1-2 Front Panel of T1500-28PCT (TL-SL2428P)
LEDsResetSFP Port10/100/1000Mbps
LED Mode
10/100Mbps RJ45
10/100/1000Mbps
RJ45 Port
01Introduction
Page 6
JetStream Smart Switch
The front panel of T1500G-10MPS is shown as the following figure.
Figu re 1-3 Front Panel of T1500G-10MPS
LEDsLED Mode
Switch Button
Reset10/100/1000Mbps
RJ45 Port and PoE Port
SFP Port
The front panel of T1600G-18TS (TL-SG2216) is shown as the following figure.
Figu re 1-4 Front Panel of T160 0G-18TS (TL-SG2216)
LEDsReset10/100/1000Mbps RJ45 Port SFP Port
The front panel of T1600G-28TS is shown as the following figure.
Figu re 1-5 Front Panel of T160 0G-28TS
10/100/1000Mbps RJ45 PortLEDsResetSFP Port
The front panel of T1600G-28PS is shown as the following figure.
Figu re 1-6 Front Panel of T160 0G-28PS
LEDsReset10/100/1000Mbps
Switch Button
RJ45 Port
SFP PortLED Mode
The front panel of The T1600G-52TS (TL-SG2452) is shown as the following figure.
Figu re 1-7 Front Panel of T160 0G-52TS (TL-SG2452)
ResetLEDs10/100/1000Mbps RJ45 PortSFP Port
02Introduction
Page 7
JetStream Smart Switch
The front panel of The T1600G-52PS (TL-SG2452P) is shown as the following figure.
Figu re 1-8 Front Panel of T160 0G-52PS (TL-SG2452P)
Reset LED Mode Switch
Button
LEDs
10/100/1000Mbps RJ45 PortSFP Port
The front panel of The T1700G-28TQ is shown as the following figure.
Figu re 1-9 Front Panel of T1700G-28TQ
LEDsUnit ID LED Reset10/100/1000Mbps RJ45 PortSFP+ Port
The front panel of The T1700X-16TS is shown as the following figure.
Off: The switch is powered off or power supply is abnormal.
Flashing: Power supply is abnormal.
Flashing: The switch works properly.
On or Off: The switch works improperly.
On: A device is connected to the corresponding port but no activity.
Flashing: Data is being transmitted or received.
Off: No device is connected to the corresponding por t.
Note: 10/100M for T1500-28TC. Link /Act for T1600G-18TS (TL-SG2216), T1600G28TS, T1700G-28TQ.
1000Mbps
On: Running at 1000Mbps.
Off: Running at 10/100Mbps or no device is linked to the corresponding por t.
Note: For T1600G-18TS (TL-SG2216), T1600G-28TS, T1700G-28TQ.
03Introduction
Page 8
JetStream Smart Switch
LEDIndication
Green On: Running at 1000Mbps, but no activity.
Green Flashing: Running at 1000Mbps and is transmitting or receiving data.
1000M
10/10 0/100 0Mbps
Link/Act
25-28
Lick /Act
Link/Act
Master
Fan
Yel low On : Running at 10/100Mbps, but no activity.
Yellow Flashing: Running at 10/100Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: 1000M for T1500 -28TC. 10/100/1000Mbps for 1-48 ports of T1600G-52TS
( TL-SG2 452 ).
On: A 1000Mbps device is connected to the corresponding SFP port but no activity.
Flashing: Data is being transmitted or received.
Off: A 10/100Mbps device or no device is connected to the corresponding SFP
port.
Note: Only for 49-52 ports of T1600G-52TS (TL-SG2452).
Green On: Running at 10Gbps, but no activity.
Green Flashing: Running at 10Gbps and is transmitting or receiving data.
Yel low On : Running at 1000Mbps, but no activit y.
Yellow Flashing: Running at 1000Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: 25-28 for T1700G-28TQ. Link/Act for 13-16 ports of T1700X-16TS.
Green On: Running at 10Gbps, but no activity.
Green Flashing: Running at 10Gbps and is transmitting or receiving data.
Yel low On : Running at 100/1000Mbps, but no activity.
Yellow Flashing: Running at 100/1000Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: Only for 1-12 ports of T1700X-16TS.
On: The switch works as master in the stack system, or does not join any stack
system.
Off: The switch works as stack member in the stack system.
Note: Only for T1700G-28TQ.
Green: All the fans work properly.
Yel low : Not all the fans work properly.
Off: The switch is working abnormally.
Note: Only for T1700X-16TS.
T1500-28PCT (TL-SL2428P) / T1500G-10MPS / T1600G-28PS / T1600G-52PS (TL-SG2452P) has an
LED mode switch button which is used to switch the LED status indication. When the Speed LED is
on, the port LED is indicating the data transmission rate. When the PoE LED is on, the port LED is
indicating the power supply status. By default the Speed LED is on. Pressing the mode switch button,
the Speed LED will turn off and the PoE LED will light up. Then the PoE LED will turn off after being on
for 60 seconds and the Speed LED will light up again.
04Introduction
Page 9
LEDIndication
On: The switch is powered on.
PWR
Off: The switch is powered off or power supply is abnormal.
Flashing: Power supply is abnormal.
SYS
FAN
PoE Max
(Wh en the PoE LE D
is on)
Flashing: The switch works properly.
On or Off: The switch works improperly.
Green: All the fans work properly.
Yel low : Not all the fans work properly.
On: The remaining PoE power≤7W.
Flashing: The remaining PoE power keeps≤7W after this LED is on for 2 minutes.
Off: The remaining PoE power>7W.
Green On: Running at 100Mbps, but no activity.
Green Flashing: Running at 100Mbps and is transmitting or receiving data.
10/10 0M or PoE
(Wh en the Spee d
LED is o n)
Yel low On : Running at 10Mbps, but no activity.
Yellow Flashing: Running at 10Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: Only for T1500 -28PCT.
Green On: Running at 1000Mbps, but no activity.
1000M
Speed or PoE
(Wh en the Spee d
LED is o n)
Green Flashing: Running at 1000Mbps and is transmitting or receiving data.
Yel low On : Running at 10/100Mbps, but no activity.
Yellow Flashing: Running at 10/100Mbps and is transmitting or receiving data.
Off: No device is linked to the corresponding port.
Note: 1000M for T1500 -28PCT. Speed or PoE for T1500G-10MPS, 1-24 ports of
T1600G-28PS and 1-48 ports of T1600G-52PS (TL-SG2452P)
Green On: The port is supplying power normally.
10/10 0M or PoE
Speed or PoE
(Wh en the PoE LE D
is on)
Green Flashing: The supply power exceeds the correponding port's maximum power.
Yel low On : Overload or short circuit is detected.
Yellow Flashing: Power-on self-test failed.
Off: Not providing PoE power on the port.
Note: 10/100M or PoE for T1500-28PCT. Speed or PoE for T1500G-10MPS, 1-24 ports
of T1600G-28PS and 1-48 ports of T1600G-52PS ( TL-SG2452P)
On:
1000Base-X
(Wh en the Spee d
LED is o n)
A 1000Mbps device is connected to the corresponding port.
Flashing:
Off: A 10/100Mbps device or no device is connected to the corresponding port.
Note: For 25-28 ports of T1600G-28PS and 49-52 ports of T1600G-52PS (TL-SG2452P)
Green On: A 1000Mbps device is linked to the corresponding port, but no activity.
Green Flashing: A 1000Mbps device is linked to the corresponding port and data is
being transmitted or received.
SFP1, SFP2
Yel low On : A 10/100Mbps device is linked to the corresponding port, but no activity.
Yellow Flashing: A 10/100Mbps device is linked to the corresponding port and is
transmitting or receiving data.
Off: No device is linked to the corresponding port but no activit y.
Note: Only for T1500G-10MPS.
JetStream Smart Switch
The corresponding port is transmitting or receiving data.
.
05Introduction
Page 10
JetStream Smart Switch
LED Mode Switch Button
Press this button to switch the LED status indication between Speed and PoE.
Reset
With the switch powered on, press Reset button for 5 seconds to reset the software setting to its factory
default settings.
Unit ID LED
Designed to display the stack Unit ID of the switch. For the switch that does not join any stack system,
it displays its default Unit ID. To modify the default unit number, please logon to the GUI of the switch
and go to Stack→Stack Management→Stack Cong page and congure the New Unit ID. The new Unit
ID will take eect after you reboot the switch.
10/100Mbps RJ45 Port
Designed to connect to the device with a bandwidth of 10Mbps or 100Mbps.
10/100/1000Mbps RJ45 Por t
Designed to connect to the device with a bandwidth of 10Mbps, 100Mbps or 1000Mbps.
SFP Port
Designed to install the SFP module. For T1500, T1500G and T1600G series products, the switch
features some slots that are shared with the associated RJ45 ports. The associated two ports are
referred as a "Combo" port, which means they cannot be used simultaneously, otherwise only SFP port
works.
SFP+ Port
Designed to install the SFP module. For T1700G-28TQ and T1700X-16TS, the switch supports 1G or
10G SFP module connection.
Port Feature
Model
T1500 -28TC042420
T1500 -28PCT042420
T1500G -10 MP S08020
T1600G -18 TS016020
T1600 G-28TS02404 0
T1600G-28PS02404 0
T1600 G-52TS048040
T1600 G-52PS048040
T1700G-28TQ024004
T1700X-16TS120004
100 M/100 0M/10 Gbps
RJ45 Por t
10/10 0/100 0Mbps
RJ45 Por t
10/10 0Mbps RJ45
Port
SFP Port SFP+ Por t
06Introduction
Page 11
JetStream Smart Switch
■
Rear Panel
The rear panel is shown as the following figure. Here we take T1600G-28TS as an example.
Figu re 1-11 Rear Panel
Power SocketGrounding TerminalKensington Security slot
Kensington Security Slot
Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal
The switch already comes with lightning protection mechanism. You can also ground the
switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed
information, please refer to the Lightning Protection Guide from the training center of our website
Connect the female connector of the power cord here, and the male connector to the AC power outlet.
Please make sure the voltage of the power supply meets the requirement of the input voltage (100-240V~
50/60Hz).
Note:
■
Please use the provided power cord.
07Introduction
Page 12
JetStream Smart Switch
40℃
Chapter 2 Installation
2.1 Package Contents
Make sure that the package contains the following items. If any of the listed items is damaged or
missing, please contact your distributor.
One Switch
One Resouce CD
One Power Cord
Two mounting brackets
Installation Guide
Business Networking Solution
Installation Guide
and the ttings
2.2 Safety Precautions
To avoid any device damage and bodily injury caused by improper use, please observe the following
rules.
■
Safety Precautions
■
Keep the power off during the installation.
■
Wear an ESD-preventive wrist strap, and make sure that the wrist strap has a good skin contact and is
well grounded.
■
Use only the power cord provided with the switch.
■
Make sure that the supply voltage matches the specifications indicated on the rear panel of the
switch.
■
Ensure the vent hole is well ventilated and unblocked.
■
Do not open or remove the cover of the switch.
■
Before cleaning the device, cut off the power supply. Do not clean it by the waterish cloth, and never
use any other liquid cleaning method.
■
Place the device with its bottom surface downward.
■
Site Requirements
Temperature/Humidity
08Installation
0℃
Page 13
JetStream Smart Switch
Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may
lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high
temperature may accelerate aging of the insulation materials and can thus significantly shorten
the service life of the device. For normal temperature and humidity of the device, please check the
following table.
EnvironmentTemperatureHumidity
Operating0
℃
Storage-40
to 40
to 70
℃
℃
℃
10% to 90%RH Non-condensing
5% to 90%RH Non-condensing
Clearness
The dust accumulated on the switch can be absorbed by static electricity and result in poor contact
of metal contact points. Some measures have been taken for the device to prevent static electricity,
but too strong static electricity can cause deadly damage to the electronic elements on the internal
circuit board. To avoid the effect of static electricity on the operation of the Switch, please attach
much importance to the following items:
■
Dust the device regularly, and keep the indoor air clean.
■
Keep the device well grounded and ensure static electricity has been transferred.
Electromagnetic Interference
Electronic elements including capacitance and inductance on the device can be affected by
external interferences, such as conducted emission by capacitance coupling, inductance coupling,
and impedance coupling. To decrease the inter ferences, please make sure to take the following
measures:
■
Use the power supply that can effectively filter interference from the power grid.
■
Keep the device far from high-frequency, strong-current devices, such as radio transmitting station.
■
Use electromagnetic shielding when necessary.
Lightening Protection
Extremely high voltage currents can be produced instantly when lightning occurs and the air in
the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong
09Installation
Page 14
JetStream Smart Switch
enough to damage electronic devices, more effective lightning protection measures should be
taken.
■
Ensure the rack and device are well earthed.
■
Make sure the power socket has a good contact with the ground.
■
Keep a reasonable cabling system and avoid induced lightning.
■
Use the signal SPD (Surge Protective Device) when wiring outdoor.
Note: For detailed lightning protection measures, please refer to the Lightning Protection Guide
from the training center of our website http://www.tp-link.com/en/conguration-guides.html.
Installation Site
When installing the device on a rack or a flat workbench, please note the following items:
■
The rack or workbench is flat and stable, and sturdy enough to support the weight of 5.5kg at least.
■
The rack or workbench has a good ventilation system. The equipment room is well ventilated.
■
The rack is well grounded. Keep the power socket less than 1.5 meters away from the device.
2.3 Installation Tools
■
Phillips screwdriver
■
ESD-preventive wrist wrap
■
Cables
Note:
These tools are not provided with our product. If needed, please self purchase them.
2.4 Product Installation
■
Desktop Installation
To install the device on the desktop, please follow the steps:
1. Set the device on a flat surface strong enough to support the entire weight of the device with all
fittings.
2. Remove the adhesive backing papers from the rubber feet.
3. Turnover the device and attach the supplied rubber feet to the recessed areas on the bottom at
each corner of the device.
10Installation
Page 15
JetStream Smart Switch
Figu re 2-1 Desktop Installation
Feet
Bottom of the Device
Notch
■
Rack Installation
To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below:
1. Check the grounding and stability of the rack.
2. Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as
illustrated in the following figure.
Figu re 2-2 Bracket Installation
Rack-mounting Bracket
Screw
3. After the brackets are attached to the device, use suitable screws (not provided) to secure the
brackets to the rack, as illustrated in the following figure.
Figu re 2-3 Rack Installation
Rack
Caution:
■
Please set 5 to 10cm gaps around the device for air circulation.
■
Please avoid any heavy thing placed on the device.
■
Please place the device with its bottom facing downwards.
■
Please mount devices in sequence from the bottom to top of the rack and ensure a certain
clearance between devices for the purpose of heat dissipation.
11Installation
Page 16
JetStream Smart Switch
Chapter 3 Connection
3.1 Ethernet Port
Connect an Ethernet port of the switch to the computer by RJ45 cable as the following figure shows.
Figu re 3-1 Conn ecting th e RJ45 Port
RJ45 Port
RJ45 Cable
3.2 SFP/SFP+ Port
The following figure demonstrates the connection of SFP port to an SFP module.
Figu re 3-2 Inserting the SFP Module
SFP/SFP+ Slot
SFP/SFP+ Module
3.3 Verify Installation
After completing the installation, please verify the following items:
■
There are 5 to 10cm of clearance around the sides of the device for ventilation and the air flow is
adequate.
■
The voltage of the power supply meets the requirement of the input voltage of the device.
■
The power socket, device and rack are well grounded.
■
The device is correctly connected to other network devices.
12Connection
Page 17
JetStream Smart Switch
3.4 Power On
Plug in the negative connector of the provided power cord into the power socket of the device, and
the positive connector into a power outlet as the following figure shows.
Figu re 3-3 Connecting to Power Supply
100-240V~50/60Hz 0.5A
Note:
The figure is to illustrate the application and principle. The power plug you get from the
package and the socket in your situation will comply with the regulation in your countr y, so they
may dier from the gure above.
3.5 Initialization
After the device is powered on, it begins the Power-On Self-Test. A series of tests run automatically
to ensure the device functions properly. During this time, its LED indicators will respond in the
following order:
1. The PWR LED indicator lights on all the time. The SYS LED and the LED indicators of all the ports
keep off.
2. After about one minute, the SYS LED and LED indicators of all the ports will flash momentarily and
then turn off.
3. Several seconds later, the SYS LED indicator will flash, which represents a successful initialization.
3.6 Accessing the Switch
After the initializaiton finished, you can access and manage the switch using the GUI (Graphical User
Inter face) or using the CLI (Command Line Inter face).
■
To access the switch using the GUI, open a web browser and type the default management address
http://192.168.0.1 in the address field, then press the Enter key. The default Username and Password
are both admin in lower case letters.
■
To access the switch using the CLI, you can use Telnet and SSH connection.
For the detailed configurations, please refer to the Configuration Guide and CLI Reference Guide.
The two guides can both be found on the resource CD or on the download center of our official
Q1. What could I do if I forgot the username and password of the switch?
Press the Reset button for at least 5 seconds to reset the system. The system will be reset to
the factory default settings, and the default login user name and password are both admin.
Q2. Why does the PWR/Power LED work abnormally?
The PWR/Power LED should be lit up when the power system works normally. If the PWR LED
worked abnormally, please take the following steps:
1. Make sure that the power cable is connected properly, and the power contact is normal.
2. Make sure the voltage of the power supply meets the requirement of the input voltage of the
switch.
Q3. What should I do if I cannot access the web management page?
Please try the following:
1. Check ever y port LED on the switch and make sure the Ethernet cable is connected properly.
2. Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
3. Power off the switch and, after a while, power it on again.
4. Make sure the IP address of your PC is set within the subnet of the switch.
5. If you still cannot access the configuration page, please restore the switch to its factory defaults.
Then the IP address of your PC should be set as 192.168.0.x ("x" is any number from 2 to 254) and
Subnet Mask as 255.255.255.0.
T1700G-28TQ: PWR, SYS, Master, Link /Act, 1000M, 25, 26, 27, 28, Unit ID
LED
T1700X-16TS: PWR, SYS, FAN, Link/Act
to
90%RH Non-condensing
to
90%RH Non-condensing
15Appendix B Specications
Page 20
FCC S TATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause
undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in
which case the user may be required to take adequate measures.
EU declaration of conformity
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2009/125/EC and 2011/65/EU.
The original EU declaration of conformity may be found at http://www.tp-link.com/en/ce
Продукт сертифіковано згідно с правилами системи УкрСЕПРО на відповідність вимогам
нормативних документів та вимогам, що передбачені чинними законодавчими ак тами України.
Safety Information
• When product has power button, the power button is one of the way to shut of f the product;
when there is no power button, the only way to completely shut off power is to disconnect the
product or the power adapter from the power source.
• Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and
voiding the limited warranty. If you need ser vice, please contact us.
• Avoid water and wet locations.
Page 21
BSMI Notice
安全諮 詢及注 意事項
• 請使用原 裝電源供應器或只能按照 本產品注明的電源類型使用本產品。
• 清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
• 注意防潮,請勿將水或其他液體潑灑到本產品上。
• 插 槽與開口供通 風使 用,以確 保本產品的操作可靠並防止過 熱,請勿堵塞 或 覆蓋開口。
• 請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不可放在密閉位置中。
• 請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。
• 此為甲類資訊技術設備,于居住環境中使用時,可能會造成射頻擾動,在此種情況下,使用者會被要求採取
某些適當的對策。
限用物質含有情況標示聲明書
限用物質及其化學符號
產品元件名稱
PCB
外殼○○○○○○
1. "超出0.1 wt %" 及 "超出0.01 wt %"
備考
2. "○"
備考
備考
系指該項 限用物質之百分比含量未 超出百分比含 量基準值。
3. " - "
系指該項限用物質為排除項目。
鉛
Pb
○○○○○○
鎘
Cd
系指限用物質 之百分比含量 超 出百分比含 量基準值。
汞
Hg
六價鉻
CrVI
多溴聯苯
PBB
多溴二苯醚
PBDE
Industry Canada Statement
CAN ICES-3 (A)/NMB-3(A)
Explanation of the symbols on the product label
SymbolExplanation
AC voltage
Indoor use only
RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic
equipment (WEEE). This means that this product must be handled pursuant to
European directive 2012/19/EU in order to be recycled or dismantled to minimize its
impact on the environment.
User has the choice to give his product to a competent recycling organization or to
the retailer when he buys a new electrical or electronic equipment.