Please read this Installation Manual carefully before installing the Air Conditioner.
• This Manual describes the installation method of the indoor unit.
• For installation of the outdoor unit, follow the Installation Manual attached to the
outdoor unit.
Veuillez lire attentivement ce Manuel d’installation avant d’installer le climatiseur.
• Ce manuel décrit la procédure d’installation de l’unité intérieure.
• Pour installer l’unité extérieure, reportez-vous au Manuel d’installation fourni avec
l’unité extérieure.
Bitte lesen Sie dieses Handbuch sorgfältig, bevor Sie mit der Installation des Klimagerätes beginnen.
• In diesem Handbuch wird die Installation der Raumeinheit beschrieben.
• Um die Außeneinheit zu installieren, folgen Sie den Anweisungen in dem Handbuch, das der Außeneinheit beiliegt.
Prima di installare il condizionatore d’aria, leggere con attenzione questo manuale d’installazione.
• Questo manuale descrive il metodo d’installazione dell’unità interna.
• Per l’installazione dell’unità esterna, fare riferimento al manuale d’installazione fornito insieme all’unità esterna.
Lea atentamente este Manual de instalación antes de proceder a la instalación del aparato de aire acondicionado.
• Este manual describe el método de instalación de la unidad interior.
• Para la instalación de la unidad exterior, consulte el Manual de instalación que acompaña a la unidad exterior.
Leia atentamente o presente Manual de Instalação antes de instalar o Ar Condicionado.
• O presente manual descreve o método de instalar a unidade interior.
• Para a instalação de uma unidade exterior, siga o Manual de Instalação que acompanha a unidade exterior.
Lees deze installatiehandleiding zorgvuldig door voordat u de airconditioner gaat installeren.
• Deze installatiemethode beschrijft de installatiemethode van de binnenunit.
• Zie voor de installatie van de buitenunit, de installatiehandleiding bij de buitenunit.
Παρακαλώ διαßάστε προσεχτικά το Ενχειρίδιο Ενκατάστασης πριν απ* την ενκατασταση του Κλιµατιστικού.
• Το παρ*ν Ενχειρίδιο περινράφει τη µέθοδο ενκατάστασης της εσωτερικής µονάδας.
• Για την ενκατάσταση της εξωθερικής µονάδας, ακολουθήστε το Ενχειρίδιο Ενκατάστασης που συνοδεύει
την εξωτερική µονάδα.
Toshiba 1074007701_COVER7/16/04, 13:383
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
ADOPTION OF NEW REFRIGERANT
• This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional
refrigerant R22 in order to prevent destruction of the ozone layer.
UTILISATION DU NOUVEAU REFRIGERANT
• Ce climatiseur est d’un type inédit qui utilise le nouveau réfrigérant HFC (R410A) au lieu du réfrigérant
traditionnel R22, afin d’éviter la destruction de la couche d’ozone.
EINFÜHRUNG EINES NEUEN KÜHLMITTELS
• Dies ist ein neuartiges Klimagerät. Anstatt des herkömmlichen Kühlmittels R22 verwendet es das neue
ozonschicht-schonende HFC Kühlmittel R410A.
ADOZIONE DI UN NUOVO REFRIGERANTE
• Questo condizionatore d’aria è di un tipo nuovo che adotta un nuovo refrigerate HFC (R410A) al posto del
refrigerante convenzionale R22, per prevenire la distruzione dello strato di ozono dell’atmosfera terrestre.
ADOPCIÓN DE NUEVO REFRIGERANTE
• Este aparato de aire acondicionado es un modelo reciente que incorpora el nuevo refrigerante HFC (R410A) en
lugar del refrigerante convencional R22 para así evitar daños en la capa de ozono.
ADOPÇÃO DO NOVO REFRIGERANTE
• Este ar condicionado é um modelo novo que adopta um novo refrigerante HFC (R410A) em vez do refrigerante
convencional R22 para evitar a destruição da cama de ozono.
TOEPASSING VAN EEN NIEUW KOELMIDDEL
• Deze airconditioner is een nieuwe type dat werkt met een nieuw koelmiddel HFC (R410A) in plaats van met het
conventionele koelmiddel R22, als bijdrage om de aantasting van de ozonlaag te reduceren.
YIOΘETHΣH NEOY ΨYKTIKOY
• To παρv Kλιµατιστικ είναι νέος τύπος που υιοθετεί νέο ψυκτικ HFC (R410A) στη θέση του
συµβατικού ψυκτικού R22 προκειµένου να βοηθήσει στην προστασία του ζοντος.
3
Toshiba 1074007701_TOC7/16/04, 13:382
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
CONTENTS
Accessory parts and parts to be procured locally .................... 1
1
PRECAUTIONS FOR SAFETY .............................................. 2
(15.9 mm (diam.), Nominal (diam.) 5/8" thick 1.0 mm)
RAV-SM801KRT-E
Connecting cable
H07RN-F or 245IEC66 (1.5 mm2 or more)
Thermal insulation for refrigerant pipe
(10 mm or more, thermal insulating foam polyethylene)
Thermal insulation for drain pipe
(10 mm or more, foam polyethylene)
Drain pipe (Outer 16 mm (diam.))
Tapes
Grounding cable (2.0 mm (diam.) or more)
3
EN
Toshiba 1074007701(01EN)_P01-107/16/04, 13:302
1
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
1
• Ensure that all Local, National and International regulations are satisfied.
• Read this “PRECAUTIONS FOR SAFETY” carefully before Installation.
• The precautions described below include the important items regarding safety. Observe them without fail.
• After the installation work, perform a trial operation to check for any problem.
Follow the Owner’s Manual to explain how to use and maintain the unit to the customer.
• Turn off the main power supply switch (or breaker) before the unit maintenance.
• Ask the customer to keep the Installation Manual together with the Owner’s Manual.
PRECAUTIONS FOR SAFETY
ENGLISH
CAUTION
• THIS AIR CONDITIONER ADOPTS THE NEW HFC REFRIGERANT (R410A) WHICH DOES NOT DESTROY
OZONE LAYER.
The characteristics of R410A refrigerant are ; easy to absorb water, oxidizing membrane or oil, and its pressure
is approx. 1.6 times higher than that of refrigerant R22. Accompanied with the new refrigerant, refrigerating oil
has also been changed. Therefore, during installation work, be sure that water, dust, former refrigerant, or
refrigerating oil does not enter the refrigerating cycle.
To prevent charging an incorrect refrigerant and refrigerating oil, the sizes of connecting sections of charging
port of the main unit and installation tools are charged from those for the conventional refrigerant.
Accordingly the exclusive tools are required for the new refrigerant (R410A).
For connecting pipes, use new and clean piping designed for R410A, and please care so that water or dust does
not enter. Moreover, do not use the existing piping because there are problems with pressure-resistance force
and impurity in it.
CAUTION
This appliance must be connected to the main power supply by means of a switch with a contact separation of
at least 3 mm.
The installation fuse (25A D type ) must be used for the power supply line of this conditioner.
• Ask an authorized dealer or qualified installation professional to install/maintain the air conditioner.
Inappropriate installation may result in water leakage, electric shock or fire.
New refrigerant air conditioner installation
To disconnect the appliance from main power supply
WARNING
• Turn off the main power supply switch or breaker before attempting any electrical work.
Make sure all power switches are off. Failure to do so may cause electric shock.
• Connect the connecting cable correctly.
If the connecting cable is connected in a wrong way, electric parts may be damaged.
• When moving the air conditioner for the installation into another place, be very careful not to enter any
gaseous matter other than the specified refrigerant into the refrigeration cycle.
If air or any other gas is mixed in the refrigerant, the gas pressure in the refrigeration cycle becomes
abnormally high and it may resultingly causes pipe burst and injuries on persons.
• Do not modify this unit by removing any of the safety guards or by by-passing any of the safety
interlock switches.
• Exposure of unit to water or other moisture before installation may cause a short-circuit of electrical
parts.
Do not store it in a wet basement or expose to rain or water.
3
2
EN
Toshiba 1074007701(01EN)_P01-107/16/04, 13:303
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
1
PRECAUTIONS FOR SAFETY
• After unpacking the unit, examine it carefully if there are possible damage.
• Do not install in a place that might increase the vibration of the unit.
• To avoid personal injury (with sharp edges), be careful when handling parts.
• Perform installation work properly according to the Installation Manual.
Inappropriate installation may result in water leakage, electric shock or fire.
• When the air conditioner is installed in a small room, provide appropriate measures to ensure that the
concentration of refrigerant leakage occur in the room does not exceed the critical level.
• Install the air conditioner securely in a location where the base can sustain the weight adequately.
• Perform the specified installation work to guard against an earthquake.
If the air conditioner is not installed appropriately, accidents may occur due to the falling unit.
• If refrigerant gas has leaked during the installation work, ventilate the room immediately.
If the leaked refrigerant gas comes in contact with fire, noxious gas may generate.
• After the installation work, confirm that refrigerant gas does not leak.
If refrigerant gas leaks into the room and flows near a fire source, such as a cooking range,
noxious gas might generate.
• Electrical work must be perf ormed by a qualified electrician in accordance with the Installation Manual.
Make sure the air conditioner uses an exclusive power supply.
An insufficient power supply capacity or inappropriate installation may cause fire.
• Use the specified cables for wiring connect the terminals securely fix. To prevent external forces
applied to the terminals from affecting the terminals.
• Conform to the regulations of the local electric company when wiring the power supply.
Inappropriate grounding may cause electric shock.
• Do not install the air conditioner in a location subject to a risk of exposure to a combustible gas.
If a combustible gas leaks, and stays around the unit, a fire may occur.
3
EN
Toshiba 1074007701(01EN)_P01-107/16/04, 13:304
3
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
2
INSTALLATION PROCEDURE
Installation diagram of indoor unit
For rear left and side pipe exit
Wall
Insert the cushion between the
indoor unit and wall, and lift indoor
unit to make work easier.
Do not allow the drain hose to sag.
Cut the piping
hole sloped
slightly
Make sure to run the drain hose
sloped downward.
Mounting the installation plate
For installation of the indoor unit,
use the paper template included.
170 m
or m
Hook
Insulate the refrigerant pipes
separately with insulation, not
1 Installation
m
ore
Hook
65 mm or more
plate
170 m
or m
m
ore
together.
Min. 6 mm thick heat resisting
polyethylene foam
The auxiliary piping can be
connected the left, rear left, rear,
A
ir filter
170
120
Pipe hole
Pipe
insulation
Mounting screw
Indoor unit
m
m
0
0
1
Hook
Hook
0
Thread
Weight
right or bottom.
Right
Rear
Bottom
0
8
1
0
0
0
1
8
0
1
Hook
Mounting screw
m
m
0
Pipe hole
Rear left
55
Left
65
Installation
plate
Indoor unit
When the installation plate is directly mounted on the wall
1. Securely fix the installation plate to the wall by scr ewing it through the upper and lower fixing holes.
2. To mount the installation plate on a concrete wall with anchor bolts, utilize the anchor bolt holes as illustrated in
the above figure.
3. Attach the installation plate horizontally to the wall.
CAUTION
When installing the installation plate with mounting screw, do not use the anchor bolt hole.
Otherwise the unit may fall down and result in personal injury and property damage.
∅5 mm hole
Clip anchor
(local parts)
Mounting screw
∅4 x 25 mm
Anchor bolt
Projection
15 mm or less
4
3
EN
Toshiba 1074007701(01EN)_P01-107/16/04, 13:305
TOSHIBA RAV-SM561KRT-E (EN) 1074007701
3
• Install the air conditioner where there is sufficient strength to withstand the weight of the unit.
Upon approval of the customer, install the air conditioner in a place that satisfies the following
conditions.
• Place where the unit can be installed horizontally.
• Place where a sufficient servicing space can be ensured for safe maintenance and check.
• Place where drained water will not cause any problem.
Avoid installing in the following places.
• Place exposed to air with high salt content (seaside area), or place exposed to large quantities of sulfide gas
• Place exposed to oil, vapor, oil smoke or corrosive gas.
• Place where organic solvent is used nearby.
• Place close to a machine generating high frequency.
• Place where the discharged air blows directly into the window of the neighboring house. (For outdoor unit)
• Place where noise of the outdoor unit is easy to transmit.
• Place with poor ventilation.
• Where the ceiling height is more than 3 m.
• Where the floor/wall/ceiling structure is unable to support the weight of the unit.
SELECTION OF INSTALLATION PLACE
WARNING
If the strength is not sufficient, the unit may fall down resulting in injury.
CAUTION
(hot spring). (Should the unit be used in these places, special protective measures are needed.)
(When installing the air conditioner on the boundary with the neighbor, pay due attention to the level of noise.)
4
• Install the air conditioner certainly at a place to sufficiently withstand the weight.
• Perform a specified installation work to guard against an earthquake.
Locate the unit so as to provide uniform circulation of chilled air.
Avoid locating the unit as shown in the bad-marked figures below:
If a good location is not possible, use a fan to circulate the air evenly throughout the room.
INSTALLATION OF INDOOR UNIT
WARNING
If the strength is insufficient, the unit may fall down resulting in human injury.
An incomplete installation can cause accidents by the units falling and dropping.
Good location
Evenly hot or cooled
Shaded area well hot or cooled
Bad location
Shaded area well hot or cooled
Bad location